• 제목/요약/키워드: electrical resistance measurement

검색결과 554건 처리시간 0.027초

현장조사를 통한 건축물 접지저항 측정용 전극 설치의 개선에 관한 연구 (A Study on the Improvement of Electrode Installation for Measurement of Ground Resistance through Investigation on the Spot in Buildings)

  • 길형준;김동우;길경석
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.92-97
    • /
    • 2011
  • This paper deals with the improvement of electrode installation for measurement of ground resistance through investigation on the spot in buildings. The investigation was carried out for an earthing terminal board for measurement of ground resistance, installation of auxiliary electrode, etc. The criteria value is set up by measuring method of ground resistance in international standard. In case of inadequate installation of auxiliary electrode, a relative error is analyzed and adequate installation method of auxiliary electrode is proposed. As a consequence, it is necessary to write direction of ground and equipment, and separate auxiliary electrode for measurement of ground resistance in order to minimize measuring error.

대전류 분류기 저항의 정밀측정 (Precise Measurement of High Current Shunt Resistance)

  • 김규태;한권수;권성원;김문석;정주영;김익수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.403-406
    • /
    • 2005
  • Precise measurement of extremely low resistance shunt is important for characterization and calibration of high current instruments. We tested resistance measurement method for extremely high current shunt (up to 140 kA), where resistance is determined by precise measurement of voltage drop at 10 A test current in the frequency range of 40 Hz to 10 kHz. For the extremely low ac voltage to be precisely measured, a verification of the measurement method was also carried, where the inherent noise is systematically evaluated. The measurement uncertainty was estimated to be $1\;\%\;at\;95\;\%$ confidence level (k=2) for about 50 $\mu\Omega$.

MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템 (The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester)

  • 부라윤;최정훈;이명의
    • 한국항행학회논문지
    • /
    • 제27권2호
    • /
    • pp.203-208
    • /
    • 2023
  • 본 연구에서는 정전류 회로와 전압 강하법을 이용한 접촉 저항 측정 회로의 정밀도를 개선하는 방법을 제안하고, MQTT 브로커 서버를 통해 접촉 저항 측정 시스템의 측정값을 모니터링할 수 있는 대시보드를 구현한다. 접촉 저항 측정 시스템은 저항값을 측정하고 무선통신을 이용해 MQTT 브로커 서버로 측정값을 전달하고, 대시보드는 Node-RED와 Node-RED-Dashboard을 이용하여 최대 4개의 접촉저항 측정 시스템의 저항값을 받아 이를 사용자 화면에 출력하여 보여준다. 사용자는 하나의 대시보드를 이용해 복수의 측정 데이터를 관리할 수 있고, MQTT 브로커 서버를 통해 다른 장치와 쉽게 인터페이스 가능하게 한다. 실제 데이터 측정을 통해 정밀도 상대표준편차가 평균적으로 40.37%, 그리고 최대 64.73% 각각 감소하여 정밀도의 개선 효과가 있다.

직류 전압/저항 비율 초정밀 측정기술 (Precision Measurement Technique of DC Voltage/Resistance Ratio)

  • 김규태;유광민
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권3호
    • /
    • pp.96-99
    • /
    • 2002
  • We developed 1:1 resistance ratio measurement system for precision measurement of a series-resistor type dc voltage divider. By using active guard technique and exchange technique, any leakage effects, which are one of the most critical error sources, were successfully removed. The best measurement uncertainty with the developed ratio measurement system was estimated to be approximately $10^{-8}\;for\;10\;k{\Omega}\;and\;100\;k{\Omega}$.

비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구 (A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology)

  • 이기연;문현욱;김동우;임용배;최동환;김용혁
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.

현장실측에 의한 메시(Mesh)접지저항 출정기법 연구 (A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements)

  • 한기붕;김삼수;정세중;이상익
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

2단자 계단식 저항기의 4단자 측정기술 (4-Terminal Measurement Technique of 2-Terminal Decade Resistor)

  • 이상화;장석명
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1798-1802
    • /
    • 2013
  • We present a technique for measuring low resistance ranges of a decade resistor with a 4-Terminal connection. With the technique the accuracy of 0.8 % was obtained for a 1 $m{\Omega}$ resistance of the decade resistor. We suggested a proper pattern 4-Terminal measurement results with several 4-Terminal pattern and adapters. Additionally, we should that precise measurements for low resistance can be made usung a digital multimeter(DMM) only.

The High Resistance Measurement up to 100 PΩ using a Low Resistance, a Low Voltage Source and a Commercial Digital Multimeter

  • Yu, Kwang Min;Lee, Sang Hwa;Kang, Jeon Hong;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1392-1397
    • /
    • 2018
  • The potentiometric measurement result for a high resistance up to $100P{\Omega}$ using a low resistance, a low voltage source and a commercial digital multimeter(DMM) is presented. With the method, a resistance can be easily, fast and economically measured. Using the method, resistance ranges over the $10G{\Omega}$ range which is difficult to measure using a commercial DMM and resistance ranges between $100T{\Omega}$ and $100P{\Omega}$ which cannot measure using an insulation tester were measured within accuracy of a few percent. It is expected that it can be useful to determine the temperature and voltage effect of a high resistance and an insulation material because it uses a reference resistance with a low resistance, very low temperature and voltage effect. Besides, it is expected that it can be useful to calibrate a dc high voltage divider with a large resistance ratio and a very low resistance because arbitrary resistance ratio measurements are possible with it.

교류저항 측정시스템 개발 (Development of AC Resistance Measurement System)

  • 김한준;유광민;강전홍;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.683-684
    • /
    • 2008
  • The resistance is frequency dependent by the Seeback effect, loading effect, Eddy current loss, uniformly distributed inductance of the resistance element and uniformly distributed self-capacitance of the resistance element and capacitance between resistance element and it's box. A precise ac resistance measurement system has been developed for using as maintaining and dissemination of national ac resistance standards. The developed resistance measurement system can be used as a instrument of national ac resistance standards at frequency less than 10 kHz and it's measurement accuracy was 0.23(${\mu}{\Omega}/{\Omega}$)+4.2 ${\mu}{\Omega}$ at 1592 Hz and 20 V.

  • PDF

대체 보조전극을 이용한 접지저항 측정 신뢰성 분석 (Trust Analysis of Ground Resistance Measurements by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.109-114
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance. The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding a trust analysis of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a neutral line multiplex ground to earth, a wire net for auxiliary electrode. This information is confirmed bv compared with the measurement value.