• 제목/요약/키워드: electrical power apparatus

검색결과 322건 처리시간 0.028초

옥외 주상용 몰드 변압기인 적용 기술 (The Applied Technology of Mold Transformer for Outdoor Use)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.23-28
    • /
    • 2000
  • Insulator systems using resin casting apparatus are useful to realize the high capacity, small size, and combined electric power equipments, and are expected to bring various advantages. In Korea, epoxy resin molded apparatus have been restricted to indoor uses till now. On the other hand, in Europe, molded insulators and transformers and so forth have been practically used since the former half of 1960's. Recently, investigation on epoxy resin materials and molded apparatus for outdoor use have ben intensively carried out. Probably, this is because electric power outdoor apparatus such as distribution transformer can be given multi-functions by using outdoor epoxy resin compound This study describes the trend on the development of epoxy mold transformers, and important technologies applied for outdoor use.

  • PDF

전력용 변압기 내부고장시 전압-차전류의 변화에 관한 연구 (Transition of voltage-differential current under internal fault on power transformer)

  • 박재세
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.92-95
    • /
    • 2004
  • Power transformer is an important apparatus in transforming and delivering the power in a power system. It shows less accident ratio than other system apparatus, but once the accident occurs, it causes long-term operation stoppage and economic loss. It brings high bad spillover effects. Therefore, the role of protective relaying, which is to prevent internal fault a power transformer is highly important. This study proposed advanced algorithm that can clearly determine internal fault of the power transformer and magnetizing inrush, through numerical analysis by using the terminal voltage and input output current.

  • PDF

고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구 (A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses)

  • 남석호;강형구
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.

Analysis on the Operational Characteristics of the Combined Generation System with Power Storage Apparatus that Apply Microcontroller

  • Lim, Jung-Yeol;Yoon, Seok-Am;Cha, In-Su
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제12B권1호
    • /
    • pp.24-30
    • /
    • 2002
  • The developments of the solar and the wind power energy are necessary since the future alternative, energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a flew faults with the weather condition. In order to solve these existing problem combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added far the present study. In an experiment, when output of combined generation system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

Investigation of SLF Interruption Capability of Gas Circuit Breaker with CFD and a Mathematical Arc Model

  • Cho, Yong-Sung;Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Woo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.354-358
    • /
    • 2013
  • This paper discusses the analysis of arc conductance in a gas circuit breaker (GCB) during current interruption process and the investigation method of the interruption capability. There are some limitations in the application of the computational fluid dynamics (CFD) for the implementation of an arc model around the current zero, despite the fact that it gives good results for the high-current phase arc. In this study, we improved the accuracy in the analysis of the interruption performance by attempting the method using CFD and a mathematical arc model. The arc conductance at 200 ns before current zero (G-200ns) is selected as the indicator to predict the current interruption of the Short Line Fault (SLF). Finally, the proposed method is verified by applying to the actual circuit breakers which have different interruption performances.

Numerical Study of SF6 arc with Copper Contamination

  • Liau Vui-Kien;Lee Byeong-Yoon;Song Ki-Dong;Park Kyong-Yop
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권6호
    • /
    • pp.233-241
    • /
    • 2005
  • The present model of a SF6 arc accounts for the copper vapour contamination from the electrodes inside a Laval nozzle of a circuit breaker. Steady state simulations have been done for the arc with electrode gap of 60mm and DC electric current of 500A, 1000A and 1500A for both cases with and without copper contamination. The effects of electrode polarity are considered for the arc current of 1000A. It was found out that evaporation of copper from the anode results in a cooling of the arc in a region close to the electrodes. The electrical potential across the electrodes is not sensitive to the presence of copper vapour, typically less than $4\%$ difference. Transient analysis has been done in order to obtain the arc properties at current zero. The arc current is increased linearly from -1000 to 0A when the upstream electrode is cathode with constant dI/dt of $27.0A/{\mu}s$ (or decreased linearly from 1000 to 0A when upstream electrode is anode). It has been predicted that the presence of copper vapour reduces the interruption capability of the breaker.

대기전력 측정을 통한 절전 잠재량 예측 (Potential Electrical Energy Saving by Stand-by Power Measurement)

  • 최재원;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.253-255
    • /
    • 1999
  • We measured stand-by power of electrical machinery and appliance which are used at office and house. And we estimated potential electrical energy saving through stand-by power and the expecting number of supplied apparatus. As a result, We can reduce electrical energy by minimizing a stand-by power consumption up to three billion kWh which are equal to about 1/3 of an atomic power plant's generating power of 1 year.

  • PDF

대전 EXPO'93 자기부상열차개발을 위한 전자석의 설계 및 특성해석 (A Magnet Design and Analysis for DAE JEON EXPO'93 Magnetic Levitation System)

  • 구대현;신판석;김용주;강도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.106-109
    • /
    • 1991
  • A magnet is designed and analysed using a finite element method program (FLUX2D), which will be employed to the 2-module MAGLEV test vehicle for developing of DAE JEON EXPO '93 Magnetic Levitation System. Levitation force. guidance force and thermal characteristics are examined according to the variation of parameters of the magnet ie. pole width, window area, rail configuration, input current and so on. An optimal geometry of the magnet are provided.

  • PDF

Natural Element Method를 이용한 전자장 해석 (Electro-Magnetic Field Computation Using the Natural Element Method)

  • 김홍규;정진교;오연호;박경엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.59-61
    • /
    • 2003
  • The natural element method is a kind of meshless Galerkin method. The shape function is derived from the natural neighbor coordinates interpolation scheme. Natural neighbor shape functions are $C^0$ everywhere, except the nodes where they are $C^0$. The numerical integration is carried out using the Delaunay triangles as the background cells. The method is applied to the test problems and simulation results show that the natural element method can give accurate solutions for the electromagnetic field problems.

  • PDF

Small-Gap을 이용한 가스차단기에서의 열가스 속도측정에 관한 연구 (A Study of Hot Gas Velocity Measurement in GCB Using Small-Gap)

  • 정진교;김홍규;송기동;박경엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1044-1046
    • /
    • 2005
  • [$SF_6$] 가스차단기를 개발하기 위해서는 차단기가 동작하는 동안에 차단기 내부에서의 유동 파라메터(압력, 밀도, 온도, 속도 등)의 값을 정확하게 분석하는 것이 매우 중요하며, 특히, 아크가 존재할 경우 열가스 이동속도에 대한 분석은 필수적이다. 본 연구에서는 small-gap 측정시스템을 이용하여 시험용차단기가 동작할 때 차단부에서 발생하는 열가스의 이동속도를 측정하기 위한 연구내용을 정리하였다.

  • PDF