• 제목/요약/키워드: electrical line contact

검색결과 195건 처리시간 0.024초

터널구간 팬터그래프와 전차선간 동적성능 검측장치 구현 (Implement of Dynamic Performance Measurement System Between Pantograph and Contact wire in Tunnel)

  • 박영;박철민;이기원;권삼영
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1732-1736
    • /
    • 2012
  • To increase speed up of train, in the field of catenary system, it is necessary to develop of new monitoring methods for dynamic interaction between pantograph and contact wire. Also, there is a need to develop technologies that constantly measure are from various railway structure such as uplift of contact wire, vibration of catenary, dynamic strain of contact line in tunnel. In this paper condition monitoring systems for dynamic performance of catenary systems in tunnel were proposed. An advanced method and results of field tests using high speed camera for monitoring of vertical upward movement of the grooved contact wire due to the force produced from the pantograph were presented. The proposed uplift measurement system of contact wire is expected to enhance precision of current collection quality performance assessment methods at high-speed lines.

Front Surface Grid Design for High Efficiency Solar Cells

  • Gangopadhyay Utpal;Kim, Kyung-Hae;Basu Prabir Kanti;Dhungel Suresh Kumar;Jung, Sung-Wook;Yia, Jun-Sin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권2호
    • /
    • pp.78-84
    • /
    • 2005
  • Standard crystalline solar cells are generally fabricated with the front grid pattern of silver paste contact. We have reported a detailed theoretical analysis of the proposed segmented cross grid line pattern in this paper. This work was carried out for the optimization of spacing and width of grid finger, main busbar and sub-busbar. The overall electrical and optical losses due to front contact were brought down to $10\%$ or even less as compared to the usual loss of $15\%$ or more in the conventional screen printed silver paste technology by choosing proper grid pattern and optimizing the grid parameters. The total normalized power loss for segmented mesh grid with plated metal contact was also observed and the total power loss could be brought down to $10.04\%$ unlike $11.57\%$ in the case of continuous grid and plated contact. This paper is able to outline the limitations of conventional screen printed contact.

낮은 접촉저항을 갖는 Ni/Si/Ni n형 4H-SiC의 오옴성 접합 (Low Resistivity Ohmic Ni/Si/Ni Contacts to N-Type 4H-SiC)

  • 김창교;양성준;조남인;유홍진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권10호
    • /
    • pp.495-499
    • /
    • 2004
  • Characteristics of ohmic Ni/Si/Ni contacts to n-type 4H-SiC are investigated systematically. The ohmic contacts were formed by annealing Ni/Si/Ni sputtered sequentially The annealings were performed at 950℃ using RTP in vacuum ambient and N₂ ambient, respectively. The specific contact resistivity(p/sub c/), sheet resistance(R/sub s/), contact resistance (R/sub c/) transfer length(L/sub T/) were calculated from resistance(R/sub T/) versus contact spacing(d) measurements obtained from TLM(transmission line method) structure. While the resulting measurement values of sample annealed at vacuum ambient were p/sub c/ = 3.8×10/sup -5/Ω㎠, R/sub c/ = 4.9 Ω and R/sub T/ = 9.8 Ω, those of sample annealed at N₂ ambient were p/sub c/ = 2.29×10/sup -4/Ω㎠, R/sub c/ = 12.9 Ω and R/sub T/ = 25.8 Ω. The physical properties of contacts were examined using XRD 3nd AES. The results showed that nickel silicide was formed on SiC and Ni was migrated into SiC. This result indicates that Ni/Si/Ni ohmic contact would be useful in high performance electronic devices.

차세대 고속전철 주행에 따른 이선현상이 전력변환 상호간에 미치는 영향분석 (An analysis of mutual influence between power conversions caused by contact loss during traction of next generation high speed train)

  • 김재문;장진영;김양수;안정준;김연준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.10-12
    • /
    • 2009
  • Electromagnetic Interference(EMI) in electric railway operation has become increasingly important. The components within very high power electronic, and the circuits for treating low-level signals, comprise complex system that must coexist and be highly reliable. To study it, It were included how much the HEMU-400X generates EMI and it has an effect on the power conversion units which resulted from Power Line Disturbance (PLD) phenomenon by contact loss during its running. In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated. The analysis of the loss of contact based on Power Simulator program software is performed to develop power line disturbance model suitable for high speed operation. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system.

  • PDF

해빙시스템을 위한 기후변화에 따른 전차선 온도특성에 관한 연구 (A Study on the Temperature Feature of Electric Car Line by the Climatic Change for the De-icing System)

  • 정명섭;김용;이병송;권삼영;정호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.305-307
    • /
    • 2005
  • In the cold and temperate regions of Korea the icing and ice coats on 25[kV] electric car line during winter is a very serious problem. This generates shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire and extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing operations should be performed just before train operation to avoid the formation of another ice layer. This paper presents temperature analysis of the de-icing system which could be applied to the electric car line of railways.

  • PDF

E-Highway를 위한 팬터그래프의 가공선 위치정보 취득에 관한 연구 (A Study on Acquisition of Overhead Line Location Information of Pantograph for E-Highway)

  • 송광철;안준재;레동부;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.915-923
    • /
    • 2023
  • As environmental regulations on carbon emissions are strengthened worldwide, the existing internal combustion engine-centered automobile industry is being reformed. In particular, large buses and large cargo trucks are pointed out as one of the main causes of environmental destruction due to excessive carbon emissions. The E-Highway power collection system, which has recently been proposed as a solution, uses the vehicle's battery as a backup power source or regenerative braking, depending on whether the pan head of the pentograph installed in the vehicle is in contact with the overhead line. It is used to store the excess energy generated. However, wear through contact due to continuous contact reduces the current collection effect and causes failure. In this paper, by using the current difference, the horizontal position information of the panhead in contact with the overhead line is acquired, thereby reducing the abrasion of the conductor and the panhead Make it possible to follow the overhead line. The position estimation method proposed in this paper simply configures a device that can detect the position of the overhead line of the pantograph by the difference in resistance. It is economical and has the advantage of reducing the volume. The characteristics of the pantograph estimating the location of overhead lines were analyzed using the difference between the two currents of the current collector, the feasibility of the positioning estimation system was verified through simulations and experiments.

절연구분장치의 속도향상 기술 (Technique on the speed up of neutral section in the catenary system)

  • 창상훈;박병수;김영곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.71-74
    • /
    • 2005
  • At the neutral sections, There are neutral sections inserted in overhead contact line between the substations to divide different phase current sections of AC electrified lines. except convention line, a large stress occurs in the contact wire near the fittings under passing pantographs. So, in order to raise the train speed over 150km/h, a new type section has been adopted.

  • PDF

도시형 자기부상열차용 집전시스템에 대한 실험적 연구(I) (An Experimental Study on the Pantograph and Contact-Line System for Urban Transit Maglev Vehicle(I))

  • 이종민;김봉섭;정현갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.43-45
    • /
    • 1998
  • This paper presents the results of an experimental study for the pantograph brush used to concact-line system in UTM-01(Urban Transit Maglev Vehicle). The contact resistance and the power collect capability are measured by the alloyed copper and the carbon brush. Measured results are considered to performance improvement for the pantograph.

  • PDF

Study on Co- and Ni-base $Si_2$ for SiC ohmic contact

  • 김창교;양성준;노일호;장석원;조남인;정경화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.167-171
    • /
    • 2003
  • We report the material and electrical properties of $CoSi_2$ and $NiSi_2$contacts to n-type 4H-SiC depending on the post-annealing and the metal covering conditions. The Ni and Co silicides are deposited by RF sputtering with Ni/Si/Ni and Co/Si/Co films separately deposited on 4H-SiC substrates. The deposited films are annealed at $800\;^{\circ}C$ in $Ar:H_2$ (9:1) gas ambient. Results of the specific surface resistivity measurements show that the resistivity of the Co-based metal contact was the one order lower than that of the Ni-based contact. The specific contact resistance was measured by a transmission line technique, and the specific contact resistivity of $1.5{\times}10^{-6}\;{\Omega}\;cm^2$ is obtained for Co/Si/Co metal structures after a two-step annealing; at $550\;^{\circ}C$ for 10 min and $800\;^{\circ}C$ for 3min. The physical properties of the contacts were examined by using XRD and AES, and the results indicate that the Co-based metal contacts have better structural stability of silicide phases formed after the high temperature annealing.

  • PDF

Development and Application of Distributed Multilayer On-line Monitoring System for High Voltage Vacuum Circuit Breaker

  • Mei, Fei;Mei, Jun;Zheng, Jianyong;Wang, Yiping
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.813-823
    • /
    • 2013
  • On-line monitoring system is important for high voltage vacuum circuit breakers (HVCBs) in operation condition assessment and fault diagnosis. A distributed multilayer system with client/server architecture is developed on rated voltage 10kV HVCB with spring operating mechanism. It can collect data when HVCB switches, calculate the necessary parameters, show the operation conditions and provide abundant information for fault diagnosis. Ensemble empirical mode decomposition (EEMD) is used to detect the singular point which is regarded as the contact moment. This method has been applied to on-line monitoring system successfully and its satisfactory effect has been proved through experiments. SVM and FCM are both effective methods for fault diagnosis. A combinative algorithm is designed to judge the faults of HVCB's operating mechanism. The system's precision and stability are confirmed by field tests.