• Title/Summary/Keyword: electrical length

Search Result 2,450, Processing Time 0.032 seconds

Miniaturization and Transmission Efficiency Improvement of Resonant Aperture Structure (공진 개구 구조의 소형화 및 투과 효율 개선)

  • Yoo, Jong-Gyeong;Yeo, Junho;Ko, Ji-Whan;Kim, Byung-Mun;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.6
    • /
    • pp.470-477
    • /
    • 2017
  • As a method of the transmission efficiency improvement of an aperture smaller than the wavelength, we modified the conventional H-shaped resonant aperture to lower the resonance frequency of resonant aperture, and the transmission efficiency of resonant aperture was improved more than the conventional aperture. The maximum transmission cross section(TCS) calculated using the equivalent circuit tends to be almost equal to the maximum TCS from the small resonant aperture modified to improve the transmission efficiency. The transmission characteristics of resonant apertures can be quantified as the TCS, and the transmission efficiency of that can be compared. The modified resonant aperture has a maximum TCS increased by about 2.87 times from $846mm^2$ to $2,431mm^2$ compared to the H-shaped aperture, and the resonant frequency decreased from 5.06 GHz to 2.92 GHz, and the length-to-wavelength ratio of the aperture was reduced from 0.178 to 0.103.

CFD Analysis on the Heat Transfer Performance with Various Obstacles in Air Channel of Air-Type PV/Thermal Module (공기식 태양광/열 시스템 공기채널 내 여러 저항체 설치에 따른 전열성능에 관한 CFD 해석)

  • Choi, Hwi-Ung;Fatkhur, Rokhman;Kim, Young-Bok;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.2
    • /
    • pp.33-43
    • /
    • 2018
  • PV/Thermal module is the combined system, which consist of a photovoltaic module and solar thermal collector that can obtain electrical power and thermal energy simultaneously. Thus the power generation can be increase by decreasing the temperature of photovoltaic module and thermal energy retrieved from module also can be used for heating system. In this study, Heat transfer performance of air type PV/Thermal module was confirmed with various bottom obstacles that can be installed easily to real photovoltaic module by CFD (computational fluid dynamics) analysis. Eight type obstacles were investigated according to the shape and arrangement. As a result, nusselt number represent heat transfer performance was increased about 86% compare with the basic type PV/Tthermal module that has no obstacle and triangle type obstacle had higher value than other types. But pressure drop was also increased with increment of heat transfer enhancement. Thus the performance factor considering both heat transfer and pressure drop was confirmed and V-fin type obstacle arranged in a row for Reynolds number below 9,600 and protrusion type obstacle arranged in zigzag for Reynolds number above 14,400 were shown higher performance factor than other types. From these results, V-fin type obstacle arranged in row and protrusion type obstacle arranged in zigzag were considered as a proper type for applying to real PV/thermal module according to operating condition. But the heat transfer performance can be changed by the geometric conditions of obstacle such as height, width, length and arrangement. Thus, it could also confirmed that the optimal condition and arrangement of this obstacle need to be found in further study.

Effect of KNO3 Priming on Various Properties of Kenaf Seed under Non-Saline and Saline Conditions

  • Lee, In-Sok;Kang, Chan-Ho;Lee, Ki-Kwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.62 no.4
    • /
    • pp.373-381
    • /
    • 2017
  • The main objective of this study was to increase the germination percentage of kenaf seeds with less number of times under non-saline and saline conditions. Therefore, the first goal was to assess the response of kenaf seeds to NaCl. The second goal was to evaluate the effects of $KNO_3$ on kenaf seed germination. The germination percentage exhibited a decreasing tendency in germination rate. Plant dry weight was approximately 0.2 g in all treatments at 5 days after germination. As time passed, the electrical conductivity (EC) value of hydro-priming (HP) consistently increased by 8.7 mS/cm at 24 hours of immersion. However, seeds primed with $KNO_3$ showed no difference in EC values even as times passed. Regarding the priming effect, priming in 100 mM $KNO_3$ concentration for 12 hours increased germination up to 85% in $H_20$ solution and in 0 mM $KNO_3$ concentration upto 73.8% under 0.3% NaCl solution, compared to that of Control. Germination synchronization, shoot length, and leaf unfolding of primed seeds were greater than those of the Control. In addition, main root and hair roots appeared more rapidly in the treated seeds and were more abundant compared to that of the Control. The T50 (times to reach 50% of the final germination percentage) of the Control in both $H_20$ and 0.3% NaCl solutions was 18 and 22 hours, respectively. However, when treated $KNO_3$ priming (0 to 100 mM) in $H_20$ and 0.3% NaCl solution, 9 hours was sufficient to reach T50. Primed (hydro-priming and $KNO_3$) seeds had a lower MDG (mean days untill germination; 0.6-0.62) compared to that of the Control (1.13-1.31) in $H_20$ and 0.3% NaCl solutions. Regarding dry weight of plants after priming, an increasing tendency after the priming treatment in the H20 solution was observed. Furthermore, no significant difference in plant dry weight under 0.3% NaCl stress was observed between the Control and primed seeds. Taken together, the results suggest that 50-100 mM $KNO_3$ priming for 24 hours optimize seed germination rate in less number of times of exposure with great vigor. Therefore, it is recommended for kenaf seed invigoration before planting.

Steady-state Thermal Analysis of 5 kW IPMSM Using Thermal Equivalent Circuit (열등가회로를 이용한 5 kW 급 영구자석 동기전동기의 정상상태 열 특성 해석)

  • Kim, Tae Hyun;Yoo, Young Bum;Na, Jong Seung;Ryu, Kyongtae;Moon, Yoon Jae;Lee, Jae Heon;Lee, Ju;Park, Chan Bae;Moon, Seung Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.951-956
    • /
    • 2014
  • Steady-state thermal analysis was performed on a thermal equivalent circuit to determine the heat generation during operation of an interior permanent magnet synchronous motor (IPMSM). New machines must be compact and light and produce high torque density under extreme environmental conditions. Thermal analysis of an IPMSM is particularly important because excessive heat generated from the core and magnet reduces the IPMSM's output and has adverse effects on the durability. Therefore, steady-state thermal analysis of an IPMSM was performed for changes in the design variables using a thermal equivalent circuit. The changed variables were the axis length and thickness of the housing. The results of this method were compared with those of the finite element method to verify the accuracy and reliability.

Laboratory Experiments for Evaluating Necking Defects in Bored Piles Embedded in Sandy Soils Using Electromagnetic Waves (전자기파를 이용한 모래 지반에 설치된 현장타설말뚝의 네킹 결함 평가를 위한 실내 모형실험)

  • Lee, Jong-Sub;Kim, Youngdae;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.5
    • /
    • pp.25-34
    • /
    • 2020
  • Studies on nondestructive evaluation methods using electromagnetic waves have been commonly conducted to evaluate necking defects in bored piles. However, the propagation of electromagnetic waves are affected by water contents of surrounding materials. This study aims to investigate a suitability of electromagnetic waves for evaluating necking defects in bored piles embedded in sandy soils through laboratory experiments. Laboratory experiments are performed with a model pile having a necking defect. The diameter and length of model pile are 600 mm and 1 m, respectively, and the model pile is embedded in sandy soils with different water contents of 10%, 20%, and 30%. For the propagation of electromagnetic waves, a transmission line is configured in reinforcement cage using an electrical wire. The generation and detection of electromagnetic waves are conducted using a time domain reflectometer. Experimental results show that the peak amplitude of electromagnetic waves reflected at the necking defect decreases with an increase in the water content in sandy soils. In addition, the velocity of electromagnetic waves reflected from the toe of the model pile decreases win an increase in the water content. However, estimated locations of the necking defects are almost the same to that of the actual location of the necking defect. This study demonstrates that electromagnetic waves may be an effective method for evaluating necking defects in bored piles embedded in sandy soils

Pulse Broadening and Intersymbol Interference of the Optical Gaussian Pulse Due to Atmospheric Turbulence in an Optical Wireless Communication System (광 무선통신시스템에서 대기 교란으로 인한 광 가우시안 펄스의 펄스 퍼짐과 부호 간 간섭에 관한 연구)

  • Jung, Jin-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.417-422
    • /
    • 2005
  • When an optical pulse propagates through the atmospheric channel, it is attenuated and spreaded by the atmospheric turbulence. This pulse broadening produces the intersymbol interference(ISI) between adjacent pulses. Therefore, adjacent pulses are overlapped, and the bit rates and the repeaterless transmission length are limited by the ISI. In this paper, the ISI as a function of the refractive index structure constant that presents the strength of atmospheric turbulence is found using the temporal momentum function, and is numerically analyzed fer the basic SONET transmission rates. The numerical results show that ISI is gradually increasing at the lower transmission rate than the OC-192(9.953 Gb/s) system and is slowly converging after rapid increasing at the higher transmission rate than the OC-768(39.813 Gb/s) system as the turbulence is stronger. Also, we know that accurate information transmission is possible to 10[km] at the OC-48(2.488 Gb/s) system under any atmospheric turbulence, but is impossible under the stronger turbulence than $10^{-14}[m^{-2/3}]$ at the 100 Gb/s system, $10^{-13}[m^{-2/3}]$ at the OC-768 system, and $10^{-12}[m^{-2/3}]$ at the OC-192 system, because the ISI is seriously induced.

A study on the Frequency Analysis Function of the Auricle Using A Notch Filter

  • Park, Dong-Cheol
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.241-255
    • /
    • 2021
  • The human auricle is the first part to receive sound from the outside. In this part, the frequency range of human recognizable form is divided and organized. In this study, we propose modeling by applying a single sound source to the surface of the human auricle. This means that when the sound pressure of a low frequency (low frequency) sound enters the pinna, the impedance felt at the tip of a part of the non-linear surface of the pinna is mainly due to the tensile force at the end of the part of the non-linear surface of the pinna. By expressing the situation of moving at a very small speed, the characteristic impedance of the pinna was confirmed to be negative infinity, and it was also confirmed that the speed at the tip of a part of the non-linear surface of the pinna was 0 in the anti-resonance state. It was found that the wave propagation phenomenon that determines the characteristics of the filter is determined by how large the wavelength, kL, is compared to the length of the tip of a part of the non-straight surface of the pinna. Humans first receive sounds from outside through their ears. The auricle is non-linear and has a curved shape, and it is known that it analyzes frequencies while receiving external sounds. The human ear has an audible frequency range of 20Hz - 20,000Hz. Through the study, we applied the characteristics of the notch filter to hypothesize that the human audible frequency range is separated from the auricle, and applied filter theory to analyze it, and as a result, meaningful results were obtained. The curved part and the inner part of the auricle function as a trumpet, collecting sounds, and at the same time amplifying the weak sound of a specific band. The point was found and the shape of the envelope detected in the auricle was found. Selectivity for selecting sounds coming from the outside is the formula of the pinna that implements the function of Q. The function of distinguishing human-recognizable sound from the pinna from low to high through frequency analysis is performed in the pinna, and the 2-3kHz area, where human hearing threshold is the most sensitive, is also the acoustic impedance of the most recessed area of the pinna. It can be seen that starting from.

Personalized Cooling Management System with Thermal Imaging Camera (열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.782-785
    • /
    • 2021
  • In this paper, we propose a personalized cooling management system with thermal imaging camera. The proposed equipment uses a thermal imaging camera to control the amount of cold air and the system according to the difference between the user's skin temperature before and after the procedure. When the skin temperature is abnormally low, the cold air supply is cut off to prevent the possibility of a safety accident. It is economical by replacing the skin temperature sensor with a thermal imaging camera temperature measurement, and it can be visualized because the temperature can be checked with the thermal image. In addition, the proposed equipment improves the sensitivity of the sensor that measures the distance to the skin by calculating the focal length by using a dual laser pointer for the safety of a personalized cooling management system to which a thermal imaging camera is applied. In order to evaluate the performance of the proposed equipment, it was tested in an externally accredited testing institute. The first measured temperature range was -100℃~-160℃, indicating a wider temperature range than -150~-160℃(cryo generation/USA), which is the highest level currently used in the field. In addition, the error was measured to be ±3.2%~±3.5%, which showed better results than ±5%(CRYOTOP/China), which is the highest level currently used in the field. The second measured distance accuracy was measured as below ±4.0%, which was superior to ±5%(CRYOTOP/China), which is the highest level currently used in the field. Third, the nitrogen consumption was confirmed to be less than 0.15 L/min at the maximum, which was superior to the highest level of 6 L/min(POLAR BEAR/USA) currently used in the field. Therefore, it was determined that the performance of the personalized cooling management system applied with the thermal imaging camera proposed in this paper was excellent.

The Effectiveness of Traditional Korean Medicine for Treating Postoperative Ileus in Gastric Cancer Patients: A Systematic Review and Meta-Analysis (위암 수술 후 장마비에 대한 한의학적 치료의 효과 : 체계적 문헌 고찰 및 메타분석)

  • Bae, Hye-ri;Kim, Eun-ji;Seo, Hyun-sik;Lee, Nam-hun
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.4
    • /
    • pp.625-642
    • /
    • 2022
  • Objectives: Postoperative ileus (POI) is a common impairment of gastrointestinal motility and causes a delay in postoperative recovery, as well as an increased length of hospital stay, but no single strategy has a significant recuperative effect on POI. Studies of traditional Korean medicine (TKM) have reported improvements in bowel function after surgery. The aim of this systematic review was to assess the effectiveness of TKM on postoperative ileus in gastric cancer patients. Methods: We used six databases to search for studies published from January 1, 2007, until May 11, 2022. The included studies were those reporting gastric cancer patients who received TKM treatment after gastrectomy through indicators related to POI. Results: The search identified 27 RCTs that used herbal medicine (Daegeonjung-tang and Gami-leejoongtang), herbal medicine combined with acupuncture (Sama-tang, Gumiseunggi-tang, Daeseunggi-tang, and Insam-tang), acupuncture, acupuncture and moxibustion, electroacupuncture, warm needling, transcutaneous electroacupuncture (TEA), low-frequency electrical acupoint stimulation (LEAS), moxibustion, auricular acupressure, and ST-36 acupoint injection with neostigmine as treatments for POI. The time to first flatus was shortened by herbal medicine combined with warm needling (Sama-tang, Gumiseunggi-tang, Daeseunggi-tang, and Insam-tang), acupuncture, electroacupuncture, warm needling, TEA, moxibustion, auricular acupressure, and ST-36 acupoint injection with neostigmine (p<0.00001). The time to the first defecation decreased significantly in response to the herbal medicine combined with warm needling (Sama-tang, Gumiseunggi-tang, Daeseunggi-tang, and Insam-tang), acupuncture, electroacupuncture, warm needling, TEA, moxibustion, auricular acupressure, and ST-36 acupoint injection with neostigmine (p<0.00001). No serious adverse events occurred. Conclusions: TKM could be a promising option for preventing and resolving POI in gastric cancer patients after gastrectomy.

The Effect of Patient-Engaged Bedside Handoffs Protocol in Comprehensive Care Units (간호·간병통합서비스 병동에서의 환자참여 침상인계 프로토콜 적용 효과)

  • Lee, Bo Young;Park, Kyung Jin;Im, Jae Hyun;Song, A Reum;Yeon, Mi Hyang;Song, Hyun Ju;Jeon, Do Jin;Baek, Kyu Won;Jang, Joo Young;Choi, Su Jung
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.3
    • /
    • pp.223-232
    • /
    • 2022
  • Purpose: The purpose of this study was to apply patient-engaged bedside handoffs in comprehensive care units, and to evaluate the effects of bedsides to nurses and patients. Methods: This study employed a cluster randomized cross-over design.Electrical Medical Record (EMR)-based handoffs and patient-engaged bedside handoffs were alternatively applied to 104 patients, who were assigned to a total of 30 clusters (nursing handoff teams) in 4 comprehensive care units at the S medical center in Seoul, and the patients evaluated each type of handoffs. A total of 139 nurses were also participated in the same units and evaluated each type of handoffs. Data were analyzed using t-test, Wilcoxon rank sum test, ANOVA, and Kruskal-Walls test. Results: The patient's satisfaction of the patient-engaged bedside handoffs was higher than that of the EMR-based handoffs (Z=-5.16, p<.001). On the other hand, the nurse's satisfaction of the patient-engaged bedside handoffs was significantly lower than that of the EMR-based handoffs (t=13.21, p<.001). There were no differences in length of the reporting time between two types of handoffs (t=-0.48, p=.634). Conclusion: Patient satisfaction with the patient-engaged bedside handoffs was higher than that of EMR-based handoffs, and nurses' satisfaction with the patient-engaged bedside handoffs was significantly lower than that of EMR-based handoffs. Future studies are needed regarding the impacts of patient-engaged bedside handoffs on the quality of healthcare by identifying the benefits of the handoffs.