Study on Decomposition Gas Characteristics and Condition Diagnosis for Gas-Insulated Transformer by Chemical Analysis

  • Kim, Ah-Reum;Kwak, Byeong Sub;Jun, Tae-Hyun;Park, Hyun-Joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.447-454
    • /
    • 2020
  • Since SF6 gas was discovered in the early 1900s, it has been widely used as an insulation material for electrical equipment. While various indicators have been developed to diagnose oil-immersed transformers, there are still insufficient indicators for the diagnosis of gas-insulated transformers. When necessary, chemical diagnostic methods can be used for gas-insulated transformers. However, the field suitability and accuracy of those methods for transformer diagnosis have not been verified. In addition, since various types of decomposition gases are generated therein, it is also necessary to establish appropriate analysis methods to cover the variety of gases. In this study, a gas-insulated transformer was diagnosed through the analysis of decomposition gases. Reliability assessments of both simple analysis methods suitable for on-site tests and precise analysis methods for laboratory level tests were performed. Using these methods, a gas analysis was performed for the internal decomposition gases of a 154 kV transformer in operation. In addition, simulated discharge and thermal fault experiments were demonstrated. Each major decomposition gas generation characteristics was identified. The results showed that an approximate diagnosis of the inside of a gas-insulated transformer is possible by analyzing SO2, SOF2, and CO using simple analysis methods on-site. In addition, since there are differences in the types of decomposition gas generation patterns with various solid materials of the internal transformer, a detailed examination should be performed by using precise analysis methods in the laboratory.

Characteristics of Insertion Loss of Adhesive Tapes to Reduce Noise through Small Opening Hole (미세한 공혈을 통한 소음의 저감을 위한 접착 테이프 별 삽입손실 특성)

  • Yong Thung Cho
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.232-237
    • /
    • 2024
  • Adhesive tapes can be conveniently used for various applications by combination of materials requiring diverse mechanical strength and specific adhesives. Duct tape is usually readily available and one of the most widely used adhesive tapes. Duct tapes are composite materials with good mechanical strength consisted of fiber material, which is different from other tapes. In addition, electrical insulation tapes are used for very long period of time for insulating cables, and are also used for reinforcement of mechanical strength and increasing damping of cable in practice. Recently, variety of foam tapes and double-sided tapes are widely used in diverse applications. However, there is no previous work readily available clearly illustrating noise isolation performance of tapes. In present work, noise isolation performance of tapes is presented by measurement of insertion loss of variety of tapes on a small hole. Double-side foam tapes presented the best noise isolation performance among adhesive tapes measured in present work.

Microwave hybrid sintering of NTC themistor (마이크로파 하이브리드 소결법에 의한 NTC 서미스터의 제조)

  • 최영락;안진용;안주삼;백동규;최승철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.3
    • /
    • pp.508-512
    • /
    • 1998
  • The NTC thermistors were sintered by using microwave hybrid heating method at $1100^{\circ}C$~$1300^{\circ}C$ and those electrical properties were investigated. The obtained $B_{25^{\circ}C/85^{\circ}C}$ values from temperature dependence of electrical resisitivity were around 3100~3200 K which were almost the same values as conventionally sintered ones. Compared with conventional sintering process, this process could complete whole sintering process within 20 minutes. This the processing time and energy consumption could be reduced through this rapid heating by using microwave hybrid heating.t there were showed only two peaks, glycolide melting peak and lower molecular weight melting peak without lauryl alcohol. Conversion increased slowly with the reaction time up to 50 minutes, and then gave a sudden increase above that. The reaction time to disappear in glycolide melting peak during polymerization was shortened with the increase of lauryl alcohol content. Zero-shear viscosity of polyglycolic acid decreased with the increase of free acid content in glycolide.ssional energy and bending hysteresis increased. \circled3 Surface characteristics such as friction coefficient and thickness variation of highly shrinkage fabrics became relatively roughened state. \circled4 Since stiffened and roughened characteristics of highly shrinkage fabrics, drapabilities of them were significantly lowered. Additionally thermal insulation property of high shrinkage fabric was higher than that of low shrinkage fabric due to bulky and thickened feature. From the results, it is considered that the silk fabrics with high filling shrinkage have the good bulkiness and heat keeping properties and thus they have the suitable characteristics for high quality men's and women's formal garments.

  • PDF

A Study on the Over-current Characteristics of IV Insulated Wire Sheath According to Accelerated Degradation (가속열화에 따른 IV절연전선 피복의 과전류 특성에 관한 연구)

  • Kim, Si-Kuk;Choi, Su-Gil
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.48-56
    • /
    • 2018
  • This paper reports the results of a study on the over-current characteristics of IV insulated wire sheath according to accelerated degradation. In order to examine the degradation of a IV insulated wire sheath through insulation, acceleration degradation experiments were performed using the Arrhenius equation of acceleration life test models; test samples with equivalent lives of 0, 10, 20, 30 and 40 years were prepared. Then allowed currents with over-current of 100%~500% were introduced to measure the times of first generation of smokes and carbonization in the wire sheath, and it was found that the times of first generation of smokes and carbonization in the wire sheath decreased as the equivalent life increased. In more detail, when 270% over-current is applied, the electrical fire risk of equivalent life of 40 years increased by approximately 3.2 times based on equivalent life of 0 years. Also, when the over-current was 255% and 260%, carbonization occurred only in the equivalent life of 40 years, and the fire risk according to the accelerated degradation was increased dramatically. In addition, FT-IR and SEM analyzes were used to confirm the characteristics and surface changes of IV insulated wire sheath according to the equivalent life.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

A Survey on Asbestos Exposure Possibility in Indoor and Outdoor Environments of Childcare Centers (어린이집 실내·외 석면노출 가능성 조사에 관한 연구)

  • Park, Whame;Son, Byeung-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.122-129
    • /
    • 2014
  • Objectives: Because of its properties such as resistance to heat, chemicals and corrosion; tensile strength; sound absorption; and affordable price, asbestos has been widely used as a building material, fire resistant and retardant, thermal and heat insulator, soundproofing material, and electrical insulation. Since the prolonged inhalation of asbestos can cause serious illnesses such as lung cancer, mesothelioma, and asbestosis after an incubation period of 20 to 40 years, the mineral was classified as a Group 1 carcinogen by the International Agency for Research on Cancer, an intergovernmental agency forming part of the World Health Organization. Children and infants are more at risk than are adults if they are exposed to carcinogens, due to aweaker immunity that has not yet been fully developed. Most childcare centers are operated all day and children tend to spend a great amount of time in the centers. This is why it is important for them to be systematically isolated from environments that may expose them to asbestos. Materials: In order to understand both indoor and outdoor hazards to which children may have been exposed, the study focused on actual surveys of asbestos used in childcare centers, paying special attention to slate-roofed buildings in the vicinity of the centers. Results: A survey of a total of 211 childcare centers showed that the buildings of 18.1% of the centers contained asbestos, with 60.53% of the material being found in classroom ceilings. "Tex" was the most used material for ceilings, making up 89.47% of all ceilings. An outdoor survey showed that childcare centers in Daegu Metropolitan City had an average of 143 slate-roof buildings within a distance of 1km. Conclusions: Buildings housing mainly toddlers, children, teenagers and others more vulnerable to the toxicity of asbestos are not subject to asbestos investigation by law. A legal and practical basis for asbestos control is required for such buildings. In particular, housing materials which contain asbestos in day care centers require asbestos control. GIS should be used to identify the location of buildings with slate roofing materials in the vicinity of daycare centers in order to gauge toxicity of exposure to asbestos caused by potential asbestos friability possibility in outdoor conditions.

Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships (선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성)

  • Lee, Yun-Hyung;Ryu, Ki-Tak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.689-696
    • /
    • 2018
  • System grounding is applied to the neutral point of a power source to secure the from any abnormal voltage and/or grounding fault. System grounding, which is applied mainly in ships is an ungrounded and resistance grounded system. Vessels using the MV power system with 3.3kV, 6.6kV, and 11kV mainly adopt a high resistance grounding system among the resistance grounding systems. The ground fault accounts for 95% of all faults occurring in the electrical system and when a fault occurs, the line-to-ground voltage of the power system is increased excessively, which adversely affects the onboard insulation system. This study analyzed the variation characteristics of the line-to-ground voltage neutral point according to the degree of ground fault in a resistance ground system applied in vessels. For this purpose, the characteristics of the grounding system were first explained, and the modeling of the neutral point potential of the line-to-ground voltage of the resistance grounding system in the vessels was derived. Finally, this study examined how the line-to-ground voltage, line voltage, and neutral point change according to various variable environments through MATLAB simulations.

Tele-metering

  • Hearte, L.O.
    • 전기의세계
    • /
    • v.2
    • /
    • pp.6-14
    • /
    • 1949
  • Telemetering may be described as the art of metering at a considerable distance those quantities which are ordinarily encountered in industry, and in the generation of electric power. It is in the production of electric power that telemetering is particularly important, for it permits the system operator, or load dispatcher, to have before him at all times a continuous graphic record of the power output of each individual generating station together with an automatically made continuous graphic record of the total system output. There desired individual graphic records may be obtained showing power flow in or out, on important tie lines, etc. Such arrangements have the very great advantage that loads may be assigned to each generating station so that the best over-all system economy may be obtained and the system operator at all times may see with his own eyes that loads scheduled are actually held at the various stations. Moreover, with such equipment, in the event of system or station trouble the load dispatcher can see exactly what station, or stations, are affected and to what extent, without having to get in touch with anyone by telephone. Decisions can, therefore, be quickly reached for rescheduling the load. One of the most accurate and reliable telemetering systems is based on the use of potentiometric circuits, the fundamentals of which are discussed below. A member of such telemetering systems have been installed for the Boston Edicon Co., Boston, Massachusetts, the Consolidated Edison Co. of New York City. The Public Service Gas & Electric Co. of Newark, new Jersey. The Philadelphia Electric Co. for Philadelphia, Pennsylvania, and the Pennsylvania Railroad Co. for their electrified zone between New York and Washington a distance of over 200 miles. The scale of the totalizing recorder for the New York area is 3,000,00 KW. That of the totalizing recorder for the Philadelphia area is 2,000,000 KW. The initial installation using this type of equipment described was placed in service for the Philadelphia Electric Co. in 1923. All of the original recording instruments are still in service, later instruments have been added to take care of additions to the power system and naturally these later recorders have incorporated in those refinements in design made since the earlier ones were manufactured. Many other installations of similar equipment have been made in the United States in various locations such as at St. Louis, on the West Coast, at Baltimore and in Washington, D.C. While the use of these basic potentiometric circuits involves the use of continuous metallic circuits of good insulation resistance and free of grounds, nevertheless, intermediate transmission links, involving and impulse method suitable for use on telephone Morse carrier channels is available. This same method may be employed on power line carrier systems and is also suitable for use on beam type microwave transmission. Many impulse type units are also used as a link in these potantiometric methods. For the sake of brevity a description is given only of these basic potentiometric circuits. If there is sufficient interest in Korea, a further paper can be given covering those impulse circuits also.

  • PDF

Effects of the Powder Preparation Method on the Magnetic Properties of Fe-based Amorphous Alloy Powder Cores (철계 비정질 합금 분말코아의 자기적 특성에 미치는 분말 제조방식의 영향)

  • Noh, T.H.;Choi, H.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.3
    • /
    • pp.191-197
    • /
    • 2005
  • In the fabrication process of Fe-based amorphous alloy powder cores by pulverization of the melt-spun ribbons and cold compaction, the effects of powder preparation method on the magnetic & electric properties, powder shapes and microstructure of cores have been investigated. The powder cores made by using rotor mill showed low effective permeability as compared to the cores prepared by ball milling. However the frequency dependence and quality factor properties were superior in the case of rotor-milling. Further the powders prepared by rotor mill had homogeneous and round shapes through strong shearing in the sieve ring, while the ball milled powders were inhomogeneous and relatively small. The lower permeability of the powder cores fabricated with rotor mill was considered to be due to the high internal stress occurred by very intensive shearing. Moreover the powder cores produced by rotor-milling showed lower core loss and good frequency dependence of effective permeability possibly due to the higher electrical insulation between magnetic particles. The dc bias property of the powder cores made by rotor-milling was better than the one by ball-milling.

Development of Backfill Materials for Underground Power Cables Considering Thermal Effect (열특성 효과를 고려한 지중송전관로용 되메움재 개발)

  • Lee Dae-Soo;Kim Dae-Hong;Hong Sung-Yun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.41-52
    • /
    • 2005
  • Because the allowable current loading of buried electrical transmission cables is frequently limited by the maximum permissible temperature of the cable or of the surrounding ground, there is a need fur cable backfill materials that can maintain a low thermal resistivity even while subjected to high temperatures for prolonged periods. Temperatures greater than $50^{\circ}C\;to\;60^{\circ}C$ may lead to breakdown of cable insulation and thermal runaway if the surrounding backfill material is unable to dissipate the heat as rapidly as it is generated. This paper describes the results of studies aimed at the development of backfill material to reduce the thermal resistivity. A large number of different additive materials were tested to determine their applicability as a substitute material. Tests were carried out for Dongrim river sand, a relatively uniform sand of very high thermal resistivity, $50^{\circ}C-cm/watt\;at\;10\%$ water content, $260^{\circ}C-cnuwatt$ when dry, and Jinsan granite screenings, and D-2 (sand and granite screenings mixture), E-1 (rubble and granite screenings mixture), a well-graded materials with low thermal resistivity, about $35^{\circ}C-cm/watt$ when at 10 percent water content, $100^{\circ}C-cm/watt$ when dry. Based on this research, 3 types of backfill materials were suggested for improved materials with low thermal resistivity and the applicability was assessed through field tests.