• Title/Summary/Keyword: electrical injury

Search Result 172, Processing Time 0.026 seconds

A Classification Study on the Consumer Product Safety Management Target for CSR Consumer Issues (CSR 소비자이슈를 위한 생활용품 안전관리대상 유형 분류형태 연구)

  • Suh, Jungdae
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.119-131
    • /
    • 2019
  • Among the themes for CSR(Corporate Social Responsibility), consumer issues include protecting the health and safety of consumers who purchase and use the products. In particular, ensuring product safety is a major theme of consumer issues for corporate social responsibility. Currently, the government implements the Electrical Appliances and Consumer Products Safety Control Act for product safety management and selects products that may harmful to consumers as safety control items, and manages the products by designating them as 4 types of safety certification, safety confirmation, supplier conformity verification, and safety standard compliance. In this paper, we propose management plans for the establishment of a more reasonable classification type of safety management target for 48 items of consumer products to be controlled by the act, and confirm the validity of the plan. First, we perform cluster analysis using data for CISS (Consumer Injury Surveillance System) to derive a new classification type of the safety management target. Next, we compare the results of the cluster analysis with the classification type of the act and the existing scenario classification method RAS (Risk Assessment by Scenario) and the causal network method RAMP (Risk Assessment Method based on Probability). Based on these results, we propose two new plans of safety management target classification and verify its validity.

Prediction of Maximal Flexion Strength for Exercise Intensity Setting and Measurement in Elbow Joint (팔꿉관절 운동강도 설정 및 측정을 위한 최대굴곡력 예측)

  • Jang, Jee-Hun;Kim, Jae-Min;Kim, Yeon-Kyu;Kim, Jin-Chul;Cho, Tae-Yong;Kim, Yun-Jeong;Lee, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1628-1633
    • /
    • 2017
  • The purpose of this study was to identify the difference and correlation in elbow joint maximal flexion strength according to measurement methods and characteristics of muscular contraction, and to develop the predictive equation of elbow joint maximal flexion strength for the optimal exercise intensity setting and accurate measurement. Subjects were 30 male university students. Elbow joint maximal flexion strength of isokinetic contraction, isometric contraction at $75^{\circ}$ elbow joint flexion position, isotonic concentric 1RM, manual muscle strength (MMT) were measured with isokinetic dynamometer, dumbbell, and manual muscle tester. Pearson's r, linear regression equation, and multiple regression equation between variables were calculated. As a result, the highest value was isometric contraction. The second highest value was MMT. The third highest value was isokinetic contraction. 1RM was the lowest. Predictive equations of elbow joint maximal flexion strength between isometric and isokinetic contraction, between isometric contraction and 1RM, among isometric contraction, 1RM, and body weight were developed. In conclusion, 1RM and isokinetic elbow joint maximal flexion strength could be seemed to underestimate the practical elbow joint maximal flexion strength. And it is suggested that the developed predictive equations in this study should be useful in criteria- and goal-setting for resistant exercise and sports rehabilitation after elbow joint injury.

Functional Electrical Stimulation: Part II (기능적 전기 자극: Part II - 척수손상인의 기능적 보행을 중심으로 -)

  • Lee, Jae-Ho
    • Physical Therapy Korea
    • /
    • v.2 no.2
    • /
    • pp.85-97
    • /
    • 1995
  • When applying FES to patients, proper evaluation must be performed prior to treating patient. Patients with thoracic lesions between $T_4{\sim}T_{12}$ are suitable for FES. However, these patients must have excitability of the leg muscles. Thus, excitability testing is an essential part of the screening program(stimulation at 80V gives a response). Before standing or walking is attempted the patients must perform restrengthening exercise, so that the Quadriceps muscle group minimum strength is 40 Nm (corresponding to a manual grade of F+ to G). After that walking and standing can be attempted. The effects of FES are as follows: prevents pressure sores; development and maintenance of muscle properties; prevents disuse atrophy and contractures.

  • PDF

A portable multichannel FES system for control of paralyzed extremities (마비된 말단근육의 제어를 위한 휴대용 다중 채널의 기능적 전기자극(FES) 장치)

  • 류영재;박봉기;김영민;임영철;김하경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.90-94
    • /
    • 1992
  • A portable multichannel functional electrical stimulation(FES) system for the fine control of the paralyzed extremities in spinal cord injury patients is described. This system is composed of a stimulation data creating system, a serial communication device, a 16-bit microprocessor, D/A converter of 32 channels and a display device. Stimulation patterns are created from analytical results of integrated EMGs during motion in normal subjects and are stored in the stimulation data creating system as data files. And then the stimulation patterns are sent to the memory in the portable multichannel FES system through serial communication interfacing device. Sophisticated fine control of paralyzed extrimities was realized by transmitting multichannel stimulation patterns to percutaneous intramuscular electrodes, which stimulate the motor function of paralyzed muscle simultaneously. Advantages of this system are as follws: 1) It is possible to modify stimulation patterns in accordance with the patient's situation. 2) This system is small and light.

  • PDF

Optimizing Design of Side Airbag Inflator using DOE Method (실험계획법을 이용한 측면 에어백 인플레이터 최적 설계)

  • Kim, Byeong-Woo;Hu, Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.10
    • /
    • pp.1189-1195
    • /
    • 2011
  • For side airbag, the pipe type inflators have been wide used while the disk type inflators have been used for front airbag. For helping to prevent injury and death the airbag inflator system should be design with great care. The present study deal with optimizing the design of side airbag inflator by finite element analysis and design of experiment method. An optimization process was integrated to determine the optimum design variable values related to the side airbag inflator. Free shape optimization method has been carried out to find a optimal shape on an side airbag inflator model. Optimization of the air bag inflator was successfully developed using Sharpe optimization was carried out to find a new geometry. The improved results compared to the base design specification were achieved from design of experiment and optimization.

Effects of Electrical Stimulation on Edema Formation in Frog Hind Limbs (전기자극이 개구리 뒷다리 부종형성에 미치는 영향)

  • Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 1995
  • The purpose of this study was to determine the effects of high voltage pulsed current(HVPC) and low voltage pulsed current(LVPC) on posttraumatic edema formation in frog hind limbs In this study, 16 bullfrogs(Rana Catesbeiana), weighting 189g to 340g were used. Limb 16 anesthetized bullfrogs were systemically injuried by weight drop. One hind limb of each frogs was randomly selected to receive continuous 120 pps HVPC and 100 pps LVPC at $90\%$ of motor threshold(HVPC : 33.3v, LVPC : 0.2-1mA). The opposite hind was remained as a control. A series of six 30-minute treatment(interrupted by 30-minute rest) was begun minutes after injury. The results were as follows. 1. Cathodal HVPC has heed shown to be effective in curbing posttraumatic edema formation in frogs, but anodal HVPC did not effect. 2. Volumes of hind limbs treated with LVPC were not significantly different over time from those of untreated hind limbs. 3. Therefore, waveform(HVPC versus LVPC) seems to influence the efficacy of electrotherapy for edema control. 4. Electrical stimulation were not increased edema formation on frog hind limbs.

  • PDF

A Study on the Form of Electric Shock Accident Using Swiss Cheese Model (스위스 치즈 모델을 적용한 철도 감전사고 발생형태에 관한 연구)

  • Yu, Ki-Seong;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1711-1716
    • /
    • 2018
  • Unlike conventional transmission and distribution lines, catenary system for operating electric railway vehicles are composed of multi-conductor groups (feeder line, contact wire, messenger wire, protection wire) and are used for railway employees, public or passengers in the station yards. Electric shock hazards are exposed and electric shocks such as death or serious injury are occurring in electric railway vehicles, railway high-voltage distribution lines, and catenary system. In order to analyze the types of electric shock accidents on railway by systematic approach method, we modeled 'unsafe behavior classification' method using swiss cheese model. Based on this method, we derived the type of electric shock accidents about railway accidents during the last 5 years by analyzing the frequency of occurrence of human errors and unsafe acts, laws and regulations related to violations, and so on.

The Effect of Microcurrent Electrical Stimulation on Muscle Atrophy Suppression in a Sciatic Nerve Injured Rat Model; Comparative Study by Current Intensity (좌골신경손상 쥐 모델을 이용한 미세전류 자극의 근위축 억제 효과 확인 및 자극 세기 별 비교)

  • Hwang, Donghyun;Kim, Seohyun;Lee, Hana;Jang, Seungjun;Kim, Sebin;kim, Tackjoong;Choi, Sooim;Kwak, Hoyoung;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.175-182
    • /
    • 2017
  • Microcurrent electrical stimulation(MES) has been used to accelerate recovery of atrophied skeletal muscle. However, convincing stimulation parameters for suppressing muscle atrophy due to injured sciatic nerve remains unclear. The objective of this study was to investigate the effective intensity of MES on restraining muscle atrophy with rat model underwent sciatic nerve injury(SNI). Twenty-5-week-old Sprague Dawley male rats were equally assigned to five groups : Control group(Control, CON, n = 4), Denervation group(Denervation, D, n = 4), Denervation with MES of $22{\mu}A$ group(Denervation + $22{\mu}A$, D+22, n = 4), Denervation with MES of $100{\mu}A$ group (Denervation + $100{\mu}A$, D+100 n = 4), Denervation with MES of $400{\mu}A$ group(Denervation + $400{\mu}A$, D+400, n = 4). To induce muscle atrophy, all rats in the D, D+22, D+100, and D+400 groups, were subjected to sciatic nerve injury on their right hindlimb and allowed to have 1 week of resting period. Following this period, rats underwent daily MES(60 min/ a day, 5times/1week) for 4 weeks. After that, we investigate morphological changes in muscle volume by using in vivo micro-computed tomography at week 0, 1, 3 and 5. After 5 weeks, the muscle volume had the highest value in D+400 group, and also noticeably increased in D+100 group compared to it in D group. The results of this study imply that MES with current intensities between $100-400{\mu}A$ can suppress muscle atrophy effectively.

Cold Tolerance Assessment of Lagerstroemia indica and Pyracantha angustifolia with Dormant Branches (배롱나무와 피라칸사 겨울 휴면지의 내한성 평가)

  • Shin, Chang-Seob
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.6
    • /
    • pp.118-125
    • /
    • 2011
  • This study was conducted to check danger of the cold injury by reviewing the lowest temperature by regions and the cold tolerance of Lagerstroemia indica and Pyracantha angustifolia. The cold tolerance of the samples treated at low temperature was evaluated by measuring electrical conductivity and observing browning of the cambium. It was proved that the lethal temperature of L. indica is below $-17.1^{\circ}C$, and that of P. angustifolia is below $-18.9^{\circ}C$. The frequency of the lowest temperature went down below $-17.1^{\circ}C$, was 7 times in Daejeon, 55 times in Cheongju and 72 times in Suwon for the last 45 years. In Daejeon, it has happened only once since 1975. The temperature dropped below $-18.9^{\circ}C$ 45 times in Cheongju and 32 times in Suwon during the same period, but it has not happened at all since 1991. It appears that the rising coefficient of the lowest temperature increases, as the latitude gets higher. As a result, L. indica and P. angustifolia which were planted in the central region of Korea, are considered in danger from freezing injury because the temperature can get very low intermittently in winter. But, the risk of freezing has reduced gradually as the lowest temperature raises each year.

Clinical and Statistical Analysis with Age in Cases of Pediatric Burn Patients (소아 화상 환자 2,795례에 대한 연령별 임상 통계학적 분석)

  • Cho, Ki-Hyun;Jang, Young-Chul;Lee, Jong-Wook;Koh, Jang-Hyu;Seo, Dong-Kook;Choi, Jai-Ku
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.445-450
    • /
    • 2011
  • Purpose: The objective of this study is to analyze the epidemiological characteristics of pediatric burn patients and to determine the targets for a pediatric burn prevention program. Methods: A retrospective review of all medical records of acute pediatric burn patients (age < 15 years old) admitted to our hospital between January 2005 and December 2009 was performed. Results: 1472 males and 1323 females were investigated, with a male to female ratio of 1.11 : 1. The greatest number of burn patients were those with an age of 1~2 years (1,463, 52.3%). Scalding burn was the most common cause of injury, which accounted for 2183 (78.1%) patients, followed by contact burns (10.5%), flame burn (4.9%), steam burn (3.6%). Especially steam burn was the second cause of injury in the age under 1 year, while flame burn was the second cause of injury in the age over 7 years. During recent 5 years, incidence of flame burn, steam burn, electrical burn gradually decreased. Variation of seasonal incidence is minimal and most of the patients (2,716 cases, 97.2%) had burns less than 20% TBSA (Total body surface area). The median hospital stay was 18.79 days, and the rate of operation was 28.6% with a high rate in electrical burn (76.2%), flame burn (50.0%), steam burn (46.1%). 6 patients died in this series, which yielded a mortality rate of 0.2%. Conclusion: Prevention efforts should reflect recent study results. Focused prevention program and campaign to make people aware of risk factors and their avoidance is required to reduce the number of burn accidents in children.