• 제목/요약/키워드: electrical grid

검색결과 2,230건 처리시간 0.026초

A Robust PLL Technique Based on the Digital Lock-in Amplifier under the Non-Sinusoidal Grid Conditions (디지털 록인앰프를 이용한 비정현 계통하에서 강인한 PLL 방법)

  • Ashraf, Muhammad Noman;Khan, Reyyan Ahmad;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.104-106
    • /
    • 2018
  • The harmonics and the DC offset in the grid can cause serious synchronization problems for grid connected inverters (GCIs) which leads not able to satisfy the IEEE 519 and p1547 standards in terms of phase and frequency variations. In order to guarantee the smooth and reliable synchronization of GCIs with the grid, Phase Locked Loop (PLL) is the crucial element. Typically, the performance of the PLL is assessed to limit the grid disturbances e.g. grid harmonics, DC Offset and voltage sag etc. To ensure the quality of GCI, the PLL should be precise in estimating the grid amplitude, frequency and phase. Therefore, in this paper a novel Robust PLL technique called Digital Lock-in Amplifier (DLA) PLL is proposed. The proposed PLL estimate the frequency variations and phase errors accurately even in the highly distorted grid voltage conditions like grid voltage harmonics, DC offsets and grid voltage sag. To verify the performance of proposed method, it is compared with other six conventional used PLLs (CCF PLL, SOGI PLL, SOGI LPF PLL, APF PLL, dqDSC PLL, MAF PLL). The comparison is done by simulations on MATLAB Simulink. Finally, the experimental results are verified with Single Phase GCI Prototype.

  • PDF

Reduction of Grid Current Harmonic Distortion through a 6th Harmonic Control Method in Grid-Connected Three-Level NPC Inverters (계통연계형 3-레벨 NPC 인버터의 6차 고조파 제어 기법을 이용한 계통 전류 고조파 저감)

  • Sin, Jiook;Bak, Yeongsu;Park, Seong-Soo;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제66권5호
    • /
    • pp.778-785
    • /
    • 2017
  • This paper presents a control method for reducing the distortion of the grid current at a grid-connected three-level neutral point clamped (NPC) inverter. The grid current is distorted from the 5th and 7th harmonic components in the stationary frame current also the 6th harmonic component in the synchronous frame current. In this paper, the 6th harmonic component on synchronous frame is controlled by using all-pass filters (APFs) and proportional integral (PI) controllers for distortion of the grid side. When transformed the 6th harmonic component is controlled, the 5th and 7th harmonic components are reduced. The validity of the proposed control method is verified by simulation and experiment results using a 25kW three-level NPC inverter.

A Study on Reliability Evaluation for Constructing Inner Grid of Offshore Wind Farm (해상풍력단지의 내부 계통망 구성을 위한 신뢰도 평가에 관한 연구)

  • Bae, In-Su;Shin, Je-Seok;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제27권11호
    • /
    • pp.89-95
    • /
    • 2013
  • In resent years, Offshore Wind Farm (OWF) is being actively developed. Typically, OWF has a better wind resource than onshore one, but also have a very high investment cost and maintenance cost. Furthermore, due to a difficulty of geographical access, OWF can be affected by the failure for a longer time. As the result, OWF has a higher loss cost. Therefore, a reliability evaluation should be performed more carefully at OWF planning stage. In this paper, a methodology for the reliability evaluation on inner grid is suggested. Inner grid connects wind turbines via submarine cables and transfers power to offshore substation. According to location of the faulted cable under layouts of inner grid, the transfer ability of inner grid is influenced. In order to indicate the transfer ability of inner grid, several indices are introduced such as PNDR, EEND and EENDC. To demonstrate the methodology described in this paper, diversity case studies were performed.

Comparison of Three Active-Frequency-Drift Islanding Detection Methods for Single-Phase Grid-Connected Inverters

  • Kan, Jia-rong;Jiang, Hui;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.509-518
    • /
    • 2019
  • A novel islanding detection method is proposed in this paper. It is based on a frequency drooping PLL, which was presented in a previous work. The cause of errors in the non-detection zone (NDZ) of conventional frequency disturbance islanding detection methods (IDM) is analyzed. A frequency drooping phase-locked-loop (FD-PLL) is introduced into a single-phase grid-connected inverter (SPGCI), which can guarantee that grid current is in phase with the grid voltage. A novel FD-PLL IDM is proposed by improving this PLL. In order to verify the performance of the proposed FD-PLL IDM, a full performance comparison between the proposed IDM and typical existing active frequency drift IDMs is carried out, which includes both dynamic performance and steady performance. With the same NDZ, the total harmonic distortion of the grid-current in the dynamic process and steady state is analyzed. The proposed FD-PLL IDM, regardless of the dynamic or steady process, has the best power quality. Experimental and simulation results verify that the proposed FD-PLL IDM has excellent performance.

VPI-based Control Strategy for a Transformerless MMC-HVDC System Under Unbalanced Grid Conditions

  • Kim, Si-Hwan;Kim, June-Sung;Kim, Rae-Young;Cho, Jin-Tae;Kim, Seok-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2319-2328
    • /
    • 2018
  • This paper introduces a control method for a transformerless MMC-HVDC system. The proposed method can effectively control the grid currents of the MMC-HVDC system under unbalanced grid conditions such as a single line-to-ground fault. The proposed method controls the currents of the positive sequence component and the negative sequence component without separating algorithms. Therefore, complicated calculations for extracting the positive sequence and the negative sequence component are not required. In addition, a control method to regulate a zero sequence component current under unbalanced grid conditions in the transformerless MMC-HVDC system is also proposed. The validity of the proposed method is verified through PSCAD/EMTDC simulation.

Electrical Automatic Control System Based on the Internet of Things

  • Jiyong, Jin
    • Journal of Information Processing Systems
    • /
    • 제18권6호
    • /
    • pp.784-793
    • /
    • 2022
  • Grid-connected distributed power generation has been widely used in green energy generation. However, due to the distributed characteristics, distributed power generation is difficult to be dynamically allocated and monitored in the electrical control process. In order to solve this problem, this research combined the Internet of Things (IoT) with the automatic control system of electrical engineering to improve the control strategy of the power grid inverter according to the characteristics of the IoT system. In the research, a connection system of the power grid inverter and the IoT controller were designed, and the application effect was tested by simulation experiments. The results showed that the power grid inverter had strong tracking control ability for current and power control. Meanwhile, the electrical control system of the IoT could independently and dynamically control the three-phase current and power. The given value was reached within 50 ms after the step signal was input, which could protect the power grid from being affected by the current. The overall system could realize effective control, dynamic control and protective control.

The Design and Implementation of an Available Bandwidth Measurement Scheme in the K*Grid System

  • Hahm, Seong-Il;Cho, Seong-Ho;Choi, Han;Kim, Chong-Kwon;Lee, Pill-Woo
    • Journal of Information Processing Systems
    • /
    • 제2권2호
    • /
    • pp.101-106
    • /
    • 2006
  • Grid computing is an emerging technology that enables global resource sharing. In Korea, the $K^*$Grid provides an extremely powerful research environment to both industries and academia. As part of the $K^*$Grid project, we have constructed, together with the Korea Institute of Science and Technology Information and a number of domestic universities, a supercomputer Grid test bed which connects several types of supercomputers based on the globus toolkit. To achieve efficient networking in this Grid testbed, we propose a novel method of available bandwidth measurement, called Decoupled Capacity measurement with Initial Gap (DCIG), using packet trains. DCIG can improve the network efficiency by selecting the best path among several candidates. Simulation results show that DCIG outperforms previous work in terms of accuracy and the required measurement time. We also define a new XML schema for DCIG request/response based on the schema defined by the Global Grid Forum (GGF) Network Measurement Working Group (NM-WG).

Improved Grid Voltage Control Strategy for Wind Farms with DFIGs Connected to Distribution Networks

  • Zhang, Xueguang;Pan, Weiming;Liu, Yicheng;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.495-502
    • /
    • 2012
  • This paper presents an improved grid voltage control strategy for wind farms with doubly-fed induction generators (DFIGs) connected to distribution networks based on an analysis of the operation limits of DFIG systems. A modified reactive power limit calculation method in different operation states is proposed and a reactive power control strategy during grid voltage dips/rises is further discussed. A control strategy for compensating unbalanced grid voltage, based on DFIG systems, by injecting negative sequence current into the grid through the grid side converter (GSC) is proposed. In addition, the negative current limit of the GSC is discussed. The distribution principle of the negative sequence current among the different DFIG systems in a wind farm is also introduced. The validity of the proposed voltage control strategy is demonstrated by Matlab/Simulink simulations. It is shown that the stability of a wind farm and the power grid can be improved with the proposed strategy.

Interpretation Works and Online Terminology Information System for the Standardization of Smart Grid Terminologies (스마트그리드 용어 표준화를 위한 뜻풀이 작업 및 온라인 용어 정보시스템 개발)

  • Hwang, Humor;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제62권3호
    • /
    • pp.293-299
    • /
    • 2013
  • Power system technologies in the area of smart grid are being converged with communication system technologies or information technologies(IT). This interdisciplinary action affects on two parts vigorously so that IT has become a essential part of power industry. But terminologies of two parts are confused and it is necessary that these are standardized to develop the industry. The interpretation works with scientific and technological standard of the smart grid terminologies which are IEC TC 57 glossary and non-glossary terminologies are introduced. Based on the interpretation works of the smart grid terminologies, an online terminology information system for the standardization of smart grid terminologies is proposed. The system provides the capability of collection and delivery of academic society opinions for the selected and interpreted terminologies.

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.