• 제목/요약/키워드: electrical grid

검색결과 2,230건 처리시간 0.026초

운전조건에 따른 펌프 터빈 시스템의 안정성 연구 (Reliability Investigation of a Pump-Turbine System at Various Operating Conditions)

  • 천청청;패트릭마크싱;최영도
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.46-52
    • /
    • 2015
  • Pump-turbine system is widely used by the hydropower industry for stabilizing the electrical grid in the vast growing economy of most developed countries. This study only investigates the Fluid-structure Interaction (FSI) analysis of the pump-turbine system at various operating conditions. The FSI analysis can show how reliable each component of the system is by providing the engineer with a better understanding of high stress and deformation points, which could reduce the lifespan of the pump-turbine. Pump-turbine components are categorized in two parts, pressurized static parts and movable stressed parts. The fixed parts include the spiral casing, top and bottom cover, stay vane and draft tube. The movable parts include guide vanes and impeller blades. Fine hexahedral numerical grids were used for CFD calculation and fine tetrahedral grids were used for structural analysis with imported load solution mapping greater than 90 %. The maximum equivalent stress are much smaller than the material yield stress, and the maximum equivalent stress showed an increasing tendency with the varying of operating conditions from partial to excessive at both modes. In addition, the total deformation of all the operating conditions showed a small magnitude, which have quite small influence on the structural stability. It can be conjectured that this system can be safely implemented.

2차원 및 3차원 전기비저항 탐사를 이용한 제당 누수 조사 (Dam seepage investigation using two- and three-dimensional resistivity surveys)

  • 이명종;김정호;송윤호;정승환
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2000년도 정기총회 및 특별심포지움
    • /
    • pp.41-53
    • /
    • 2000
  • 제당의 누수부위 조사를 위하여 전기비저항 탐사가 많이 이용되고 있는 바, 전기비 저항 탐사를 이용한 누수부위의 파악은 주로 제체 내 불균질대의 규명을 통하여 이루어지고 있다. 본 연구에서는 제당의 누수부위 탐지를 위한 전기비저항 탐사의 3차원 유한요소 수치모델링을 수행하고 이 결과를 이용하여 제당 누수부위 조사를 위한 2차원 및 3차원 전기비저항 탐사 방법론 및 자료의 해석에 대하여 고찰하였다. 제체의 형상과 전기비저항 구조는 근본적으로 3차원이므로 종래의 2차원 전기비저항 탐사에 비하여 비록 격자상의 측선 배열을 적용할 수 없더라도 3차원적으로 탐사를 수행하고 이를 해석함으로써 좀 더 정확한 제체하부의 영상화가 가능함을 보였다.

  • PDF

LVDC 배전을 위한 출력 380V DC-DC 컨버터 설계에 관한 연구 (A study on the Design of Output 380V DC-DC Converter for LVDC Distribution)

  • 김필중;양성수;오병윤
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.208-215
    • /
    • 2020
  • 본 연구에서는 LVDC 배전용 출력 380V DC-DC 컨버터를 3가지 유형으로 설계하였고, 시뮬레이션을 통해 3가지 유형의 DC-DC 컨버터의 전압과 전류 특성을 비교 분석하였다. 전력용 MOSFET와 2개의 전류억제용 IGBT를 병렬구조로 적용하여 컨버터를 구성한 경우, 출력 전압이 DC 380V로 안정화 된 시간이 9ms로 비교적 짧았으며, 출력 측 전류 변화 폭도 44.8~50.2A로 IGBT를 적용하지 않았을 경우(68~83A) 보다 훨씬 변화 폭도 작고 전류억제 효과도 더 뛰어남을 알 수 있었다. 이러한 결과는 제안한 LVDC 배전용 DC-DC 컨버터가 스마트 그리드 구축에 적용 가능성이 있음을 시사한다.

납 축전지의 병렬운전시 부하분담률 개선 (Improved Load Sharing Rate in Paralleled Operated Lead Acid Batteries)

  • 반한식;최규하
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.34-42
    • /
    • 2001
  • 전지는 화학에너지를 기계적인 처리과정 없이 전기에너지로 직접 전환하는 장치이다. 부하전압과 부하전류의 용량에 따라 단위전지를 직.병렬 연결하여 사용하게 되며, 전지의 병렬운전은 단독운전 보다 전압강하를 더 천천히 발생시키므로 전압강하에 민감한 전력변환장치들의 효율에 밀접한 관계를 가지고 있다. 병렬운전의 필요성과 장점 때문에 대부분의 축전지를 사용하는 시스템은 병렬운전을 하고 있고, 반면에 선.구 축전지 사이에서 순환 전류가 흐르고, 자가방전이 일어나는 단점 또한 가지고 있다. 신 축전지에서 충.방전 전류가 과다하게 흐르는 불평형 현상과 이로 인해 축전지의 수명단축을 일으키게된다. 본 논문에서는 마이크로 프로세서를 사용하여 선.구 축전지 사이의 볼평형 전류를 검출하고 외부저항을 첨가시켜 내부저항의 차이에 대한 감소효과를 얻어 불평형 전류를 보상하였다. 이를 실험을 통해 구현하였다.

  • PDF

기력발전소 터빈조속기 제어로직 개선에 의한 발전기 부하추종성 향상 (계통주파수저하방지) (Load Following Operation Improvement by Governor Control Logic Modification of Thermal Power Plant (System Frequency Drop Prevention))

  • 이종하;김태웅
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.302-306
    • /
    • 2006
  • 기력발전소의 부하추종성능의 향상은 계통의 전력품질에 지대한 영향을 미치기 때문에 이를 위해서는 먼저 보일러, 터빈, 조속기 시스템과 제어알고리즘에 대한 분석이 필히 선행되어야 한다. 기력발전설비는 다양한 제어가구들 에 의해 운영되고 있고 조속기가 고장 난 경우에는 문제를 해결하는데 많은 시간이 필요하여 발전설비를 정지하지 않고서는 메커니즘 정비가 불가능하다. 계획되지 않은 발전시스템의 정지는 전력발전의 감소로 인해 경제적인 문제뿐만 아니라 전력공급의 차질에 지대한 지장을 주기 때문에 충분히 고려할 사항이다. 본 논문에서는 표준석탄화력 500MW 발전설비 ( 삼천포화력발전소 )에 있어서 계통주파수가 과다하게 장시간 저하될 경우에 기력발전기 제어특성이 나빠져 발전기의 출력이 저하되는 데 이에 대한 현상을 추이분석과 함께 제어로직의 분석 및 개선을 통해 계통 주파수가 저하되는 것을 방지하였고 이에 대한 사례를 소개한다.

영구자석형 풍력-디젤 복합발전시스템 모델링 및 운전제어 알고리즘에 관한 연구 (Modeling & Operating Algorithm of Islanding Microgrid with PMSG Wind Turbine and Diesel Generator)

  • 김재언
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.6419-6424
    • /
    • 2015
  • 현재 도서지역에 도입되어 운용되고 있는 풍력-디젤 하이브리드 발전시스템에는 풍속과 부하변동에 대하여 적정범위의 전압주파수를 갖는 전력을 공급하기 위하여 고가의 제어가 복잡한 플라이휘일 또는 배터리 에너지저장장치를 설치운영하고 있다. 그러나, 본 논문은 이와 같이 비경제적이고 복잡도가 높은 에너지저장장치를 설치하지 않고, 풍속 및 부하변동에도 안정적인 운전이 가능한 영구자석형(PMSG: Permanent Magnet Synchronous Generator) 풍력-디젤 복합발전시스템으로 구성되는 독립형 마이크로그리드의 운전제어 알고리즘과 모델링 방법을 제안하였다. 먼저, 부하 및 풍속변동에 관계없이 적정범위의 전압주파수를 유지할 수 있는 PMSG 풍력발전기의 운전제어 알고리즘을 제안하고, 이를 바탕으로 한 전가변속 운전이 가능한 PMSG, WT측 컨버터 및 Grid측 컨버터를 모델링하고, 이를 독립형 마이크로그리드에 적용하여 풍속 및 부하변화에 대하여 전압주파수가 적정범위내로 잘 유지됨을 입증하였다.

광역 전력계통 주파수 감시망 적용을 위한 광역계통주파수의 전파속도에 관한 연구 (Study on the Propagation Speed of the wide-area power system frequency for the application of FNET)

  • 국경수;노대석
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.1824-1831
    • /
    • 2009
  • 본 논문은 대규모 전력 송전망에서 발전기가 사고로 인해 순간적으로 전력공급을 중단하게 되었을 때 과도기간 동안 나타나는 전력계통 주파수의 급강하가 탈락된 발전기의 위치로부터 전력 송전망 전체로 파급되어 가는 전파속도를 분석한다. 이러한 전력계통 주파수 동요의 전파속도는 전력계통 고유의 특성에 따라 다르게 나타나기 때문에 광역적 측면에서 전력 수송망의 특성을 이해하는데 중요한 파라미터이며, 최근 미국의 전력 송전망을 대상으로 운영중인 광역 전력계통 주파수 감시스템(FNET)을 활용한 전력 IT 적용연구에서 중요한 파라미터로 활용되고 있다. 본 논문에서는 방대한 규모를 가진 미 동부의 전력송전 연계계통에 대해 최근의 동적모델을 사용하여 다양한 위치에서의 발전기 탈락을 모의한 후 이에 따른 전력계통주파수 동요의 전파 특성을 분석하고 그 전파속도를 제시한다.

전기저항치에 의한 생리적 근첨(根尖)의 측정에 관한 연구 (A STUDY OF DETERMINATION OF PHYSIOLOGICAL ROOT APEX BY ELECTRICAL RESISTANCE VALUE)

  • 윤기복
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.25-31
    • /
    • 1981
  • One of the most important factors for successful endodontic therapy is an accurate length determination of physiological root apex. Some methods suggested for the measurement of root canal length, include digital-tactile sense and roentgenographic technique with measuring wire, scale and grid. But these methods do not derermine an accurate working length to physiological root apex. Recently electronic measuring devices are used to locate the physiological root apex in root canal length determination and these devices are accepted as an effective apparatus. The 89 patients (116 teeth, 144 canals) among the out-patients of Yonsei University Dental Infirmary, who had had an endodontic treatment in the Department of Operative Dentistry, were measured by the Root-Canal Meter$^{(R)}$ as an electronic device, and radiographs to determine the distribution and location of physiological root apex, then the following results were made: (1) Range of ${\pm}$1mm from the radiographic root apex were present in 88.88% (128 canals) of the subjects. (2) Physiological root apex and radiographic root apex were coincided in 31.94% (46 canals) of the subjects. (3) The actual length of the physiological root apex of the teeth were as follow; A : in the maxillary central incisor : 0.46mm B : in the maxillary lateral incisor : 0.44mm C : in the maxillary canine : 0.44mm D : in the maxillary 1st premolar : a) Buccal : 0.59mm b) Lingual : 0.34mm E : in the maxillary 2nd premolar : 0.54mm F : in the maxillary 1st molar : a) Mesio-buccal : 0.50mm b) Disto-buccal : 0.42mm c) Lingual : 0.56mm G : in the mandibular central incisor : 0.62mm H : in the mandibular lateral incisor : 0.45mm in the mandibular canine : 0.54mm J : in the mandibular 1st premolar : 0.47mm K : in the mandibular 2nd premolar : 0.34mm L : in the mandibular 1st molar : a) Mesio-buccal : 0.54mm b) Mesio-lingual : 0.31mm c) Distal : 0.37mm.

  • PDF

Analysis of Multi-Agent-Based Adaptive Droop-Controlled AC Microgrids with PSCAD: Modeling and Simulation

  • Li, Zhongwen;Zang, Chuanzhi;Zeng, Peng;Yu, Haibin;Li, Hepeng;Li, Shuhui
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.455-468
    • /
    • 2015
  • A microgrid (MG) with integrated renewable energy resources can benefit both utility companies and customers. As a result, they are attracting a great deal of attention. The control of a MG is very important for the stable operation of a MG. The droop-control method is popular since it avoids circulating currents among the converters without using any critical communication between them. Traditional droop control methods have the drawback of an inherent trade-off between power sharing and voltage and frequency regulation. An adaptive droop control method is proposed, which can operate in both the island mode and the grid-connected mode. It can also ensure smooth switching between these two modes. Furthermore, the voltage and frequency of a MG can be restored by using the proposed droop controller. Meanwhile, the active power can be dispatched appropriately in both operating modes based on the capacity or running cost of the Distributed Generators (DGs). The global information (such as the average voltage and output active power of the MG and so on) required by the proposed droop control method to restore the voltage and frequency deviations can be acquired distributedly based on the Multi Agent System (MAS). Simulation studies in PSCAD demonstrate the effectiveness of the proposed control method.

ESBL: An Energy-Efficient Scheme by Balancing Load in Group Based WSNs

  • Mehmood, Amjad;Nouman, Muhammad;Umar, Muhammad Muneer;Song, Houbing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권10호
    • /
    • pp.4883-4901
    • /
    • 2016
  • Energy efficiency in Wireless Sensor Networks (WSNs) is very appealing research area due to serious constrains on resources like storage, processing, and communication power of the sensor nodes. Due to limited capabilities of sensing nodes, such networks are composed of a large number of nodes. The higher number of nodes increases the overall performance in data collection from environment and transmission of packets among nodes. In such networks the nodes sense data and ultimately forward the information to a Base Station (BS). The main issues in WSNs revolve around energy consumption and delay in relaying of data. A lot of research work has been published in this area of achieving energy efficiency in the network. Various techniques have been proposed to divide such networks; like grid division of network, group based division, clustering, making logical layers of network, variable size clusters or groups and so on. In this paper a new technique of group based WSNs is proposed by using some features from recent published protocols i.e. "Energy-Efficient Multi-level and Distance Aware Clustering (EEMDC)" and "Energy-Efficient Multi-level and Distance Aware Clustering (EEUC)". The proposed work is not only energy-efficient but also minimizes the delay in relaying of data from the sensor nodes to BS. Simulation results show, that it outperforms LEACH protocol by 38%, EEMDC by 10% and EEUC by 13%.