• Title/Summary/Keyword: electrical frequency

Search Result 9,931, Processing Time 0.034 seconds

Microwave Photonics Frequency-Converted Link Using Electroabsorption Devices

  • Wu, Y.;Shin, D.S.;Chang, W.S.C.;Yu, P.K.L.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.1
    • /
    • pp.74-81
    • /
    • 2004
  • We propose a novel scheme to transmit high center frequency RF signals using electroabsorption devices (EADs) as frequency converters at the transmitter and the receiver. In this approach frequency heterodyning is employed for obtaining high center frequency. With the EAD as a detector/mixer at the receiver we demonstrated a smaller conversion loss than that of the conventional modulator/mixer. With EAD as a modulator/mixer at the transmitter and with two heterodyned lasers to generate an optical local oscillator (LO), we demonstrated a large reduction (${\sim}23dB$) in conversion loss, and the transmission is not limited by the optical saturation of the EAD. This transmission scheme has optical single-side-band transmission feature which greatly relieves the fiber dispersion effect.

A Comparative Study on Frequency Estimation Methods

  • Kim, Yoon Sang;Kim, Chul-Hwan;Ban, Woo-Hyeon;Park, Chul-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2013
  • In this paper, a comparative study on the frequency estimation methods using IRDWT (Improved Recursive Discrete Wavelet Transform), FRDWT(Fast Recursive Discrete Wavelet Transform), and GCDFT(Gain Compensator Discrete Fourier Transform) is presented. The 345[kV] power system modeling data of the Republic of Korea by EMTP-RV is used to evaluate the performance of the proposed two kinds of RDWT(IRDWT and FRDWT) and GCDFT. The simulation results show that the frequency estimation technique based on FRDWT could be the optimal frequency measurement method, and thus can be applied to FDR(Fault Disturbance Recorder) for wide-area blackout protection or frequency measurement apparatus.

Fast Locking FLL (Frequency Locked Loop) For High - speed Wireline Transceiver (고속 locking time을 갖는 Frequency Locked Loop(FLL))

  • Song, Min-Young;Lee, In-Ho;Kwak, Young-Ho;Kim, Chul-Woo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.509-510
    • /
    • 2006
  • FLL (Frequency Locked Loop) is the core block for high-speed transceiver. It incorporates a PLL for fine locking action, and a coarse controller for coarse locking action. A coarse controller compares frequencies coarsely and is applied to detected frequency difference directly. Compare to conventional FLL, frequency is applied to proposed FLL. Proposed FLL in this paper achieves only 5 cycles for coarse lock and total frequency locking time is 5 times faster than conventional FLL. Thus, proposed FLL is more useful to Ethernet transceiver application that requires high-speed data transfer than conventional FLL. Proposed FLL is based on $0.18{\mu}m$ process.

  • PDF

Effects of Pain and Functional Recovery when Low Frequency Electrical Stimulation and Aqua-exercise Applied to Sciatic Nerve Injured Rats (좌골신경손상 백서의 통증과 기능회복에 저주파 전기자극과 수중운동이 미치는 효과)

  • Kim, Young-Eok
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.6 no.1
    • /
    • pp.17-30
    • /
    • 2008
  • This study was investigated the effects of pain and functional recovery when low frequency electrical stimulation and aquatic exercise applied to sciatic nerve injured rats. The rats were assigned into four groups; Group I(n=20, control group), Group II(n=20, low frequency electrical stimulation group), Group III(n=20, aquatic exercise group), Group (n=20, applied low frequency electrical stimulation and aquaatic exercise group). Each IV group measured hot plate examination, sciatic nerve functional index(SFI), c-fos.. In hot plate examination, group II, IV showed effect than group Iat 14 days after injured(p<0.01) and group III, Ⅳ showed effect than group I at 21, 28 days after in-jured(p<0.01, p<0.001). In SFI, group II, III, IV showed effect II, III, IV than group I and group IV showed effect than group II at 14, 21 days after injured(p<0.001). group II, III, IV showed effect than group I at 28 days after injured(II = p<0.01, III and IV = p<0.001). Effects of pain and function recovery when low frequency electrical stimulation and aqua-exercise applied to sciatic nerve injured rats, group Ⅳ were most effected to sciatic nerve injured rats. As well as group II and III were effected to sciatic nerve injured rats.

  • PDF

Zero Voltage Soft Switching PWM High-Frequency Inverter with Active Inductor Snubber for Induction Heated Roller in New Type Copy Machine

  • Muraoka S.;Feng Y.L.;Kunimoto H.;Chandhaket S.;Okuno A.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.75-79
    • /
    • 2001
  • This paper presents a novel version of an active voltage clamped ZVS-PWM high frequency inverter using IGBTs for electromagnetic induction eddy current-based rolling drum heating in new generation copy and printing machines in consumer business use. The operating principle of this inverter circuit and unique features are described herein. Its constant frequency duty cycle (asymmetrical PWM) controlled voltage source quasi-resonant soft switching high frequency inverter employing IGBTs is proposed, which is capable of achieving stable and efficient zero voltage soft switching commutation over a widely specified power regulation range from full power to low power. The operating performances in a steady state of this inverter is discussed and evaluated on basis of simulation and experimental results as an induction heated roller in new generation copy machine.

  • PDF

Analysis and Application of Repetitive Control Scheme for Three-Phase Active Power Filter with Frequency Adaptive Capability

  • Sun, Biaoguang;Xie, Yunxiang;Ma, Hui;Cheng, Li
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.618-628
    • /
    • 2016
  • Active power filter (APF) has been proved as a flexible solution for compensating the harmonic distortion caused by nonlinear loads in power distribution power systems. Digital repetitive control can achieve zero steady-state error tracking of any periodic signal while the sampling points within one repetitive cycle must be a known integer. However, the compensation performance of the APF would be degradation when the grid frequency varies. In this paper, an improved repetitive control scheme with frequency adaptive capability is presented to track any periodic signal with variable grid frequency, where the variable delay items caused by time-varying grid frequency are approximated with Pade approximants. Additionally, the stability criterion of proposed repetitive control scheme is given. A three-phase shunt APF experimental platform with proposed repetitive control scheme is built in our laboratory. Simulation and experimental results demonstrate the effectiveness of the proposed repetitive control scheme.

Centralized Adaptive Under Frequency Load Shedding Schemes for Smart Grid Using Synchronous Phase Measurement Unit

  • Yang, D.Y.;Cai, G.W.;Jiang, Y.T.;Liu, C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.446-452
    • /
    • 2013
  • Under frequency load shedding (UFLS) is an effective way to prevent system blackout after a serious disturbance occurs in a power system. A novel centralized adaptive under frequency load shedding (AUFLS) scheme using the synchronous phase measurement unit (PMU) is proposed in this paper. Two main stages are consisted of in the developed technique. In the first stage, the active power deficit is estimated by using the simplest expression of the generator swing equation and static load model since the frequency, voltages and their rate of change can be obtained by means of measurements in real-time from various devices such as phase measurement units. In the second stage, the UFLS schemes are adapted to the estimated magnitude based on the presented model. The effectiveness of the proposed AUFLS scheme is investigated simulating different disturbance in IEEE 10-generator 39-bus New England test system.

Field-Oriented Speed Control of Induction Machine without Speed Sensor in Overall Speed Range (속도검출기가 없는 유도전동기의 광범위한 속도 영역에서의 자속 기준 속도 제어)

  • Ryu, Hyeong-Min;Ha, Jeong-Ik;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.338-344
    • /
    • 2000
  • This paper proposes a field-oriented control strategy without speed sensor in overall speed range. At low speed region including zero speed, the electrical saliency which is due to the main flux saturation is used in order to estimate an instantaneous flux position. This electrical saliency can be obtained from the difference of high frequency impedance by the high frequency signal injection. This method enables the stable operation at zero speed or stator frequency even under heavily loaded condition. However, because of the high frequency signal injection the loss and noise in motor increase and the voltage margin is reduced as the motor speed increases. Therefore, this algorithm must be supplemented with the algorithm based on the electrical model of motor, which is conventionally used in the region except the low speed. This paper proposes the combination algorithm between the high frequency signal infection method and the adaptive observer, in which the rotor flux and motor speed can be simultaneously estimated by the adaptive control theory. This combination algorithm enables the stable operation of field-oriented speed control without speed sensor in overall speed range. This is verified by experimental results.

  • PDF

Effects of Interfering Current Stimulation on Vastus Medialis Oblique and Vastus Lateralis Activity and Ratio during Squat Exercise (스쿼트 운동 시 적용된 중주파 전기자극이 안쪽빗넓은근과 가쪽넓은근의 근활성도 및 근활성비에 미치는 영향)

  • Kim, Chung-Yoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.283-289
    • /
    • 2021
  • Purpose : The purpose of this study is to investigate the effect of mid frequency electrical stimulation during squat exercise on the muscle activity and muscle activity ratio of vastus medialis oblique and vastus lateralis, and to prepare scientific basic data for exercise intervention using mid frequency electrical stimulation. Methods : This study was conducted with students from University C located in Busan, and among a total of 123 subjects, 12 subjects who complained of knee joint dysfunction between 80 and 90 points using the Kujala patellofemoral score (KPS) were used. All subjects participated in the experiment for 3 days, and MVIC values were measured for normalization of muscle activity values on the first day. For the two days, participants participated in the experiment and performed squat exercise or squat exercise receiving mid-frequency electrical stimulation in random order. Measurements were taken in the squat position immediately after the squat exercise, and muscle activities of vastus medialis oblique and vastus lateralis were measured. The measured data were compared through the dependent t test, and the statistical significance level was set to .05. Results : According to the results of this study, in the case of applying mid-frequency electrical stimulation together in the ratio of vastus medialis oblique and vastus lateralis muscle activity during squat exercise, higher values were observed compared to the case of not applying mid-frequency electrical stimulation together, and statistically significant. Also, when mid-frequency electrical stimulation was applied to both vastus medialis oblique and vastus lateralis activities during the squat exercise, higher values were shown compared to the case where the mid-frequency electrical stimulation was not applied together, but there was no statistically significant difference. Conclusion : The results of this study reported that mid-frequency electrical stimulation provided to vastus medialis oblique increased the muscle activity ratio of vastus medialis oblique and vastus lateralis. Therefore, the improvement of coordination due to the enhancement of the activity of vastus medialis oblique through mid-frequency electrical stimulation will be more helpful in the treatment of patellofemoral pain syndrome patient. In addition, it is hoped that the electrical stimulation method applied to exercise will be widely used.

Low Frequency Current Ripple Mitigation of Two Stage Three-Phase PEMFC Generation Systems

  • Deng, Huiwen;Li, Qi;Liu, Zhixiang;Li, Lun;Chen, Weirong
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2243-2257
    • /
    • 2016
  • This paper presents a two stage three-phase proton exchange membrane fuel cell (PEMFC) generation system. When the system is connected to a three-phase load, it is very sensitive to the characteristics and type of the load. Especially unbalanced three-phase loads, which result in a pulsating power that is twice the output frequency at the inverter output, and cause the dc-link to generate low frequency ripples. This penetrates to the fuel cell side through the front-end dc-dc converter, which makes the fuel cell work in an unsafe condition and degrades its lifespan. In this paper, the generation and propagation mechanism of low frequency ripple is analyzed and its impact on fuel cells is presented based on the PEMFC output characteristics model. Then a novel method to evaluate low frequency current ripple control capability is investigated. Moreover, a control scheme with bandpass filter inserted into the current feed-forward path, and ripple duty ratio compensation based on current mode control with notch filter is also proposed to achieve low frequency ripple suppression and dynamic characteristics improvement during load transients. Finally, different control methods are verified and compared by simulation and experimental results.