• 제목/요약/키워드: electrical fire statistics

검색결과 22건 처리시간 0.023초

선풍기의 운전 상황별 발열특성 및 전류신호 검출 (Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations)

  • 김두현;이흥수
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

아산화동증식 발열에 의한 화재 사례의 분석 (Analysis of a Fire Case Caused by Heat Generation due to Cu2O Breeding)

  • 박진영;이의평
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.54-63
    • /
    • 2020
  • 전선 접속부 등에서 아산화동(Cu2O)증식 발열에 의해 화재가 발생하는 것은 화재조사 전문가들에게 널리 알려져 있지만 아산화동증식 발열에 의한 화재사례를 구체적으로 분석하여 소개하는 논문은 거의 없다. 이 논문에서는 전기적인 접속부분의 발열에 의한 화재 통계와 아산화동증식 발열 현상과 특징을 분석한 후 아산화동증식 발열에 의해 대학실험실의 전선 접속부분에서 화재가 발생한 사례에 대해 구체적으로 분석하고 있다. 이 화재사례는 발화개소의 화재패턴 조사, 전선 접속부분에 대한 육안 조사, 3차원 CT 촬영 조사, 전원인가 시험, 실체현미경 조사, SEM과 EDS 분석을 통해서 전선 접속부분에서 아산화동 증식 발열로 인해 화재가 발생한 것으로 결론을 내릴 수 있었다.

일반용 전기설비 안전관리의 문제점과 개선방안 (Problems and Improvement Method of Safety Management of Electrical Facilities for General Use)

  • 전정채;전현재;이상익;유재근
    • 한국산학기술학회논문지
    • /
    • 제8권3호
    • /
    • pp.488-495
    • /
    • 2007
  • 일반용 전기설비의 정기적인 전기안전 점검과 부적합 설비의 개선조치에도 불구하고 전기화재의 80% 이상이 일반용 전기설비에서 발생하였으며 전기안전점검제도에 대한 이해부족, 미점검 수용가 증가, 누전차단기 미설치 및 부적합 시설의 방치 등의 원인으로 전기안전사고를 예방하는 것이 더욱 어려워진다. 본 논문에서는 일반용 전기설비의 전기안전점검 제도, 안전점검결과 및 전기화재 통계를 분석하천 관련 문제점을 도출하였다. 또한 전기안전점검제도, 점검업무 수행 방법, 전기화재 통계 수립 및 전기안전의식, 원격전기안전점검 체계 측면에서 일반용 전기설비 안전관리 개선방안을 제시하였다.

  • PDF

아크 회로의 특성 분석 및 AFCI 설치로 인한 사회적 비용평가에 관한 연구 (Research on Characteristics of Arcing Circuit and Evaluation of Societal Cost caused by AFCI Installation)

  • 박치현;배석명;임용배;김기현;최명일
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.144-150
    • /
    • 2007
  • 전력사용이 증가함에 따라 전기설비에 의한 전기화재 발생이 증가하고 있다. 통계에 따르면 전기화재가 화재원인 중 가장 높은 비중을 차지하고 있음을 알 수 있다. 그럼에도 불구하고 전기화재를 사전에 예방할 수 있는 조사기법이 아직은 부족한 실정이다. 이 논문은 전기화재 원인과 아크차단기의 특성에 관하여 분석한다. 먼저 아크차단기와 기존의 배선용 차단기를 비교하고 전력의 수학적 분석을 통해 아크에 의한 위험성을 분석하고 회로의 단락에 의한 위험성과 비교한다. 또한 아크차단기 설치와 사회적 비용간의 관계에 대해 알아봄으로써 아크차단기의 필요성을 제기한다.

자동차화재 실태 분석 (Analysis of Actual State of Motor Vehicle Fires in Korea)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.47-59
    • /
    • 2011
  • 화재통계연보와 국가화재정보시스템의 자료를 기초로 자동차화재 실태를 분석한 결과 아래와 같은 내용을 파악할 수 있었다. 자동차화재는 매일 16건 이상 발생하여 0.5명 이상의 사상자와 5천만원 이상의 직접적인 재산손실이 발생하고 있다. 자동차화재의 원인은 기계적 요인이 가장 많고 이어서 전기적 요인과 방화 순이며, 전체화재 중 방화의 비율은 7.39%이지만 차량화재 중 방화화재의 비율은 13.79%이다. 연간 자동차화재 100건당 사망자는 평균 0.9명이며 부상자는 평균 2.4명이다. 전체 자동차화재 중 고속도로에서 발생하는 화재건수가 12.55%를 차지하고 있음에도 고속도로 자동차화재의 사망자는 16.12%, 부상자는 21.05%, 재산피해는 20.65%를 차지하고 있다.

계층분석과정(AHP)을 이용한 전기안전기술 우선순위 및 추진방향 분석연구 (The Analysis of the Priority and Progress Direction of Electrical Safety Technology using Analytic Hierarchy Process)

  • 김한상;이건호;김동우;전정채;이기연;김영석;정진수
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1784-1791
    • /
    • 2013
  • Electrical safety technique is a disaster prevention technology to protect the life and property of the people and it has high correlation with all electricity industry. According to the latest statistics, loss of human life and property damage due to electrical fire have increased from 2011. Therefore, technological development for guarantee safety of electrical facilities for customer will become more important. In this paper, we drew priority and weigh for the electrical safety technology using analytic hierarchy process and present progress direction of each technology through Risk-Return assessment. We expect development of the research and development policies of government about electrical safety technology in a higher state and think that policymakers and experts will be more interested in these fields based on this paper.

관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심 (A study on Fire Case and Countermeasure of Tourist Hotel)

  • 한석만;손정현;김종원
    • 한국재난정보학회 논문집
    • /
    • 제8권4호
    • /
    • pp.362-375
    • /
    • 2012
  • 관광호텔은 숙박과 음식점, 운동, 휴양 등의 부대시설을 함께 갖춘 불특정 이용객과 투숙객 이 많은 복합시설로서 화재발생에 따른 인명피해와 재산손실에 매우 취약한 위험이 상존하는 시설이다. 본 연구에서는 관광호텔의 화재발생 현황에 대한 2001년부터 2010년까지 10 년간의 화재통계분석과 대형 호텔화재사례 15건을 분석하였다. 화재발생 장소는 호텔 객실 (33.2%)과 음식점 주방(11.8%)가 주요 발생장소이며 주요 화재원인인 전기화재(40.8%), 담배화재(14.5%), 용접 등 화기작업(9.2%) 등으로 나타났다. 또한 화재사례연구에서는 방화구획설치 및 관리 불량, 가연내장재 사용 등이 연구기간 동안 반복적으로 모든 사례에서 나타나서 주요 화재위험으로 분석되었다. 관광호텔은 이러한 화재위험의 특성에 따라 적합한 방화위험관리의 개발과 현장 운영이 필요하다. 예방점검, 사용자 교육 및 훈련, 투숙객의 화재예방안내 등의 적극적 예방관리가 필요하다. 또한 화재의 연소확대를 차단하기 위한 방화구획의 관리, 스프링클러 등의 자동소화설비를 설치가 필요하며, 가연성 물질의 사용 을 자제하여야 하고, 투숙객 피난 안전에 대한 신속한 조치, 비상절차 등과 관련된 비상대응규정의 운용이 매우 중요하다.

화염으로 인한 ACSR 송전선의 수명예측에 관한 연구 (A Study on the Life-Time Estimation of ACSR Transmission Line Due to a Flame)

  • 김영달
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.77-84
    • /
    • 2005
  • 수명예측을 하기 위한 기초 자료로 ACSR의 기계적 시험의 일종인 인장시험이 필요하다. 이 인장시험의 결과들이 경년 변화에 대해 어떤 상관관계가 있는가를 파악하여 통계적으로 처리함으로써 수명예측을 해 볼 수 있다. 통계적 처리기법으로는 회귀분석 방법이 일반적이다. 본 연구에서는 ACSR의 인장시험을 건전 전선과 인공화염으로 열화시킨 전선과, 산불 화염 의해 수거된 열화된 전선에 대해 실시하였다. 수명예측의 한계는 캐나다 Ontario Hydro Research의 기준인 정격 인장강도의 20[%] 손실점을 택하였다. 본 연구에 이용된 ACSR의 규격은 ACSR $480[mm^2]$을 대상으로 하여 비선형 회귀분석을 실시하여 예측수명을 제시하였다.

유화유 생산의 적정 인화점에 관한 연구 (A Study on the Optimal Flash-Point of WDF Production)

  • 이진;김화성
    • 한국전기전자재료학회논문지
    • /
    • 제33권4호
    • /
    • pp.310-314
    • /
    • 2020
  • Although waste oil derived fuel (WDF) production technology was developed under a government initiative ~10 years ago, it became stagnant owing to the small size of participating companies, residents' rejection of foul odor, and the nature of the technology for recycling waste that was avoided. However, this subject is under the spotlight again because of recent developments, such as garbage crisis. In particular, plastic is the most difficult waste to dispose of, with more than 4 million tons of plastic waste produced every year according to statistics from the Ministry of Environment. The most effective method for treating plastic waste is to produce WDF through low temperature thermal decomposition. The WDF includes several volatile ingredients that mostly limit the use of fuel for boilers, owing to safety concerns. In particular, flash point is legally stipulated because of secondary contamination in the distribution process and the risk of fire and explosion. It is required that external shipments (distribution) should be maintained in the range of at least 30~60℃ (excluding explosion prevention facilities) for diesel power generation. Therefore, this study seeks to find the flash point that is best suited to WDFs produced from plastic waste.

Server-Side 방식의 상황 인식 기반 선박 USN 미들웨어 구현 및 설계 (A Design and Implementation Vessel USN Middleware of Server-Side Method based on Context Aware)

  • 송병호;송익호;김종화;이성로
    • 대한전자공학회논문지SP
    • /
    • 제48권2호
    • /
    • pp.116-124
    • /
    • 2011
  • 본 논문에서는 해양 환경의 특성을 고려하여 선박 환경에 적합한 방식으로 Server-side 방식에 따른 선박 USN 미들웨어를 구현하였다. 다중 질의 처리 모듈에서는 선박USN에 구성된 다차원 센서 스트림 데이터를 효율적으로 처리하기 위해서 최적화된 질의 계획으로 Mjoin 질의와 해쉬 테이블을 이용한 최적화 방법을 제시하고 모듈을 구성하였다. 상황 인식 관리 모듈에서는 해양의 특성을 고려하여 선박의 상황을 인식하고 관리하는 방법을 제시하였고 SVM 알고리즘을 이용하여 위험 상황을 판단하였다. 제안한 SVM 알고리즘을 이용하여 각 상황별로 5,000 건의 데이터를 입력 받아 실험한 결과 화재 상황과 선체 위험 상황에 대한 평균 정확도는 87.5%, 85.1%를 보였고, 측정 결과를 전송하여 선박 USN 모니터링 시스템을 구현하였다.