• Title/Summary/Keyword: electrical cabinet system

Search Result 34, Processing Time 0.024 seconds

Design of Power Controller for Control Rod Drive Mechanism Control System (제어봉 구동장치 제어시스템용 전력함 설계)

  • Nam, J.H.;Lee, J.M.;Jung, S.H.;Shin, J.R.;Cheon, J.M.;Kim, C.K.;Kim, S.J.;Kweon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2271-2273
    • /
    • 2003
  • Control Rod Control System(CRCS) is to control nuclear reaction of reactor by moving Control Rod Drive Mechanism(CRDM) with speed and direction signal from Reactor Regulating System(RRS). CRCS is made up of two parts : control cabinet and power cabinet. And this paper presents mainly power cabinet design for system reliability. To increase reliability of power cabinet, controller, power supply and communication line arc doubly designed and supervision and diagnosis function are applied.

  • PDF

A Shaking Table Test for an Re-evaluation of Seismic Fragility of Electrical Cabinet in NPP (원전 전기캐비넷의 지진취약도 재평가를 위한 진동대 실험)

  • Kim, Min-Kyu;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.295-305
    • /
    • 2011
  • In this study, a seismic behavior of electrical cabinet system in Nuclear Power Plants(NPPs) was evaluated by the shaking table test. A 480V Motor Control Centers(MCCs) was selected for the shaking table test, and a real MCC cabinet for the Korea Nuclear Power Plant site was rented by manufactured company. For the shaking table tests, three kinds of seismic input motions were used, which were a US NRC Reg. guide 1.60 design spectrum, a UHS spectrum and PAB 165' floor response spectrum(FRS). Especially, the UHS input motion was selected for an evaluation of structural seismic amplification effects, three directional accelerations were measured at three points outside on the cabinet system and also that of the incabinet response amplification, accelerations were measure at two points which were mounted in electrical equipment such as relay. Seismic amplification effect is determined at the outside and inside of a cabinet as input seismic motion, and compared to the results which are calculated by analytical method based on NUREG/CR-5203.

Development of KNGR-CEDMCS Prototype Using DCS for Nuclear Power Plant (원전용 분산제어시스템을 이용한 차세대 원전 제어봉 구동장치제어시스템 원형 개발)

  • Cheon, Jong-Min;Lee, Jong-Moo;Kim, Choon-Kyung;Park, Min-Kook;Kwon, Soon-Man;Shin, Jong-Ryeol
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2275-2277
    • /
    • 2004
  • Korea Next Generation Reactor(KNGR) is in the midst of being developed and will exceed Korea Standard Nuclear Power Plant(KSNP) economically. Domestic Instrumentation and Control(I&C) systems shall be applied to KNGR and the development of Control Element Drive Mechanism Control System(CEDMCS) considered as an essential part in nuclear I&C system will be dealt with in this paper. The newly developed CEDMCS has the control cabinet using the nuclear Distributed Control System(DCS) made in Korea and the power cabinet produced by our research institute and interfaced with the DCS control cabinet.

  • PDF

A Development of Intelligent Metering and Control System for Energy Management of Electric Cabinet Panel (분전반 전력관리용 지능형 계측 제어 시스템 개발)

  • Park, Byung-Chul;Park, Jae-Sung;Song, Sung-Kun;Shin, Joong-Rin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.90-97
    • /
    • 2013
  • In recent years, the many electric saving methods are studied because of difficulty of meeting the demand. The electric energy management such as monitoring of branch power consumption, demand control, metering, power quality monitoring, electric safety monitoring can make energy saving. The purpose of this paper is to develop a system which can provide the integrated management of various functions required for energy management by consumers. In this system all functions which were embodied into each devices are integrated into intelligent meter. The developed systems are tested and implemented by installing at consumer electric distribution panel.

Development of a fixer attaching robot system (픽서 접합 로봇 시스템의 개발)

  • Park, Sang-Sin;Sung, Young-Whee;Kim, Dong-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2093-2102
    • /
    • 2010
  • In this paper, we introduce a fixer attaching robot system which is used to attach several fixers to a TV cabinet. It is necessary to automate the fixer attaching process for two reasons. One is that the process is very harmful because very strong ultraviolet rays are used in that process. The other is that the productivity and the overall quality of the end-product are determined by the fixer attaching process. We proposed 9 candidates for the robot system to be used in the fixer attaching process. Then we simulated cycle time for each of the 9 candidates with considering physical constraints. We also considered other aspects such as the easiness of implementation, possible interference with other mechanical structure, and cost etc. to choose one of the 9 candidates. We implemented the chosen robot system and adopted it in a TV manufacturing process.

Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function (데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Seok-Myung;Joo, Nam-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.

Damage Pattern Analysis of Voltage Cabinet Panel due to Flame (분전반의 화염에 의한 소손패턴 분석)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Kim, Man-Geon
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.37-40
    • /
    • 2008
  • This paper deals with damage patterns of cabinet panel for low voltage deteriorated by flame. In order to analyze damage patterns, we used Metallurgical Microscope, x-ray system, and Fourier Transform Infrared spectroscopy. Firstly, Metallurgical microscope was used for analysis of electrical causes, such as electric short and overload Secondly, X-ray system was used for analysis of internal characteristics of circuit breakers. Lastly, Fourier Transform Infrared spectroscopy was used for analysis of damage direction by flame.

  • PDF

Damage Pattern Analysis of Low Voltage Cabinet Panel due to Flame (저압 분전반의 화염에 의한 소손패턴 분석)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Hyang-Kon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.269-272
    • /
    • 2008
  • This paper deals with damage patterns of cabinet panel for low voltage deteriorated by flame. In order to analyze damage patterns, we used Metallurgical Microscope, x-ray system, and Fourier Transform Infrared spectroscopy. Firstly, Metallurgical microscope was used for analysis of electrical causes, such as electric short and overload. Secondly, X-ray system was used for analysis of internal characteristics of circuit breakers. Lastly, Fourier Transform Infrared spectroscopy was used for analysis of damage direction by flame. The following results were obtained.

  • PDF

Design of Control Cabinet in Control Rod Control System Using Distributed Control System for Nuclear Power Plant (원전용 분산제어시스템을 이용한 원자로 제어봉제어시스템 제어함 설계)

  • Cheon, Jong-Min;Kim, Seog-Ju;Kim, Choon-Kyung;Lee, Jong-Moo;Kwon, Soon-Man;Jeong, Soon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2200-2202
    • /
    • 2004
  • This paper deals with the design of the Control Cabinet in Control Rod Control System(CRCS), using a domestic Distributed Control System(DCS) developed to localize the instrumentation and control(I&C) system for nuclear power plant(NPP). There are many parts developed by domestic skill and being operated successfully in NPP, but the development of I&C system as an essential part has been slow in progress. We will show the great possibility of developing our own I&C system by applying this domestic DCS to nuclear I&C system and confirming its successful operation, in this paper.

  • PDF

Effects of the Excitation Level on the Dynamic Characteristics of Electrical Cabinets of Nuclear Power Plants (진동수준이 원자력발전소 전기 캐비닛의 동특성에 미치는 영향)

  • Cho, Sung-Gook;Kim, Doo-Kie;Go, Sung-Hyuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.23-30
    • /
    • 2010
  • Seismic qualification (SQ) is required prior to the installation of safety related electrical cabinets in nuclear power plants (NPPs). Modal identification of the electrical equipment is one of the most significant steps to perform SQ, and is an essential process to construct a realistic analytical model. In this study, shaking table tests were conducted to identify a variation of the dynamic characteristics of a seismic monitoring system cabinet installed in NPPs according to the excitation level. Modal identification of the cabinet has been performed by a frequency domain decomposition method. The results of this study show that the dynamic properties of the cabinet are nonlinearly varied according to the excitation level and the specimen behaves significantly in a nonlinear manner under safe shutdown earthquake motion in Korea. The main sources of the nonlinear behavior of the specimen have been judged by friction forces and geometrical nonlinearity rather than material nonlinearity. The nonlinear variation of the dynamic characteristics of the electrical cabinet might be accepted as an important fact that should be considered during the SQ of safety related equipment.