• Title/Summary/Keyword: electric resistivity

Search Result 441, Processing Time 0.026 seconds

A study on the application of testing termination for XLPE Power Cable by Resistivity Grading Method Using Semi-conductive material (반도전 재료를 이용한 Resistivity grading 방식의 XLPE절연 전력케이블용 시험단말에 관한 연구)

  • Lee, C.Y.;Shin, D.S.;Dudkin, Sergey M.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1105-1107
    • /
    • 1999
  • The purpose of termination for high voltage tests of XLPE power cable is to prevent flashover during the breakdown test of specimen as well as to withstand the specified voltage between its conductor and screen without failure. For easier treatment and simpler construction of testing termination, resistivity grading method using semi-conductive material was employed. Based on the fundamental theory, its failure characteristics by changing the resistivity of semi-conductive material on the insulation surface was investigated. With two layers construction by difference resistivity on their surfaces, much improved result than that of one resistivity was obtained through the experiment for MV cable.

  • PDF

Interference effect by electric utilities at electric resistivity Survey of fill dam (필댐의 전기비저항 탐사시 전기매체에 의한 영향 분석 연구)

  • Kim, Jae-Hong;Shin, Dong-Hoon;Im, En-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1037-1040
    • /
    • 2009
  • Using much most electricity electric resistivity survey by nondestructiveness inquiry enforcement design of country base equipment business and facilities preservation administration dimension electric resistivity survey sends and cause much effects in survey believability by electricity medium of survey personality survey contiguity that grasp base special quality by potential difference flowing current artificially in base. Is item that enforce in most in-suite although when make electric resistivity survey until present, electricity medium or effect research by electricity origination was gone much. There is shortcoming that must be difficult to know correct underground utilities establishment state in-suite in this research and do comparison examination running parallel drilling investigation to heighten believability of electric resistivity survey. Did to dam that censure data that regulate grading from construction and is censure construction which can know correctly interior base situation comparatively to electricity medium of interior and electricity eruption won of contiguity and base condition (base rock).

  • PDF

Interference effect by underground utilities at electric resistivity Survey (전기비저항 탐사시 지하매설물에 의한 간섭효과 연구)

  • Kim, Jae-Hong;Oh, Byung-Hyun;Im, En-Sang;Lee, Jong-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.961-965
    • /
    • 2009
  • Using much electric resistivity survey to design or preservation administration of facilities. However, By survey method that electric resistivity survey grasps special quality in base by potential difference creating artificial current in underground, Is influenced in electric resistance propensitys of various underground utilities in base. This Study selects dam 1 place that could grasp well underground situation and studied electricity interference effect by effect of underground utilities. Grasp underground utilities of dam interior, and control and observed accuracy with survey wave because various pole space. Through this Study, wish to present survey method of electric resistivity survey at design or survey of preservation administration dimension after with drawn result.

  • PDF

Negative Apparent Resistivity in Resistivity Method (전기비저항탐사에서 음의 겉보기 비저항)

  • Cho In-Ky;Kim Jung-Ho;Chung Seung-Hwan;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.199-205
    • /
    • 2002
  • In the resistivity method, the potential difference between two grounded electrodes is measured and this can be positive or negative. The apparent resistivity and the potential difference have the same polarity. Since the electric field is the gradient of the potential, the polarity of the potential difference depends on the direction of the electric field. If the direction of the vector connecting two grounded electrodes is the same to that of the electric field, the measured potential difference and the apparent resistivity become positive. If the opposite is the case, they become negative. In general, the primary electric field and the vector connecting two potential electrodes have the same direction in a surface resistivity method. In this case, the measured potential difference is always positive because the primary electric field is greater than the secondary field. Therefore, the apparent resistivity is always positive if noise is free and topography is flat. The secondary field component, however, can be greater than the primary field component along the vector connecting two potential electrodes in the cross-hole resistivity method. Furthermore, if the secondary electric field and the vector connecting two potential electrodes have an opposite direction, the apparent resistivity become negative. Consequently, the apparent resistivity may be negative in the region where the primary electric field component along the vector connecting two potential electrodes is very small.

A Model Study on the Variation of Apparent Resistivity along with Electric Resistivity Change of Host Rock (모암(母岩)의 전기비저항(電氣比抵抗) 변화(變化)에 따른 외견비저항(外見比抵抗)의 변화양상(變化樣相)에 관(關)한 모형연구(模型硏究))

  • Min, Kyung Duck;Jun, Myoung Soon
    • Economic and Environmental Geology
    • /
    • v.13 no.3
    • /
    • pp.159-166
    • /
    • 1980
  • A model study was conducted for the investigation of apparent resistivity variation along with electric resistivity variation of host rock and dip variation of bed. Experiments were carried out for the cases of horizontal and dipping beds in a water tank by using Wenner and Schlumberger arrays and by changing salinity of water. The ratios of resistivity values of the bed to that of brine were 1 : 10, 1 : 50, 1 : 100 and 1 : 500. Natural coally-shale of $55cm{\times}35cm{\times}3.5cm$ was used as a bed for experimental model, and brine as a host rock. Equi-resistivity curves and characteristic curves were obtained for each case of the experiment. The equi-resistivity curve was drawn both on the cross section parallel to strike of bed and longitudinal section perpendicular to it. The characteristic curve was drawn on the cross section. In the case of dipping bed of different dips, the curves are parallel to the boundary of the bed in the upper part of the bed, and are inclined to the opposite direction with the same angle of the dip of bed in the lower part. We can deduce, from the equi-resistivity curves, the location, shape and dip of the bed. It is shown in the characteristic curves that when the ratio of resistivity value of bed to that of host rock increases, the slope of curves becomes steeper, location of low-resistivity zone lower, and the width of it narrower. The slope of curves also becomes steeper when dip of bed increases. We can deduce, from the characteristic curves, the ratio of resistivity values between adjacent beds. It was found out from the experiments that electric resistivity method could be applicable to prospecting for underground geology with an electric resistivity contrast of 1 : 10. This fact strongly suggests that distinction of coal from coally-shale could be possible in a certain field condition.

  • PDF

The Quantitative Evaluation of Aging State of Field Composite Insulators Based on Trap Characteristics and Volume Resistivity-Temperature Characteristics

  • Liang, Ying;Gao, Li-Juan;Dong, Ping-Ping;Gao, Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1355-1362
    • /
    • 2018
  • In order to obtain a better understanding of the ageing process of the field composite insulators, it is necessary to explore a quantitative-valuation method for the aging state evaluation. And the linear relationship between volume resistivity and temperature is proposed. In this paper, the composite insulators with different lengths of operating lives from two manufacturers were tested. The relationship between trap characteristics and volume resistivity-temperature characteristics were analyzed based on Thermal Stimulated Current (TSC), volume resistivity-temperature test, Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). Furthermore, the application of trap characteristics in the quantitative evaluation of aging state of composite insulators was discussed. The results showed that there was a general negative correlation between the relative variation ratio of trap charges and the volume resistivity-temperature characteristics. Meanwhile, the physicochemical properties would change with the aging time, which would result in the increasing of electron traps. Combined with the TSC and volume resistivity test results, the trap characteristic thresholds which indicated the serious age of the composite insulators had been proposed.

Estimation of the zone of excavation disturbance around tunnels, using resistivity and acoustic tomography

  • Suzuki Koichi;Nakata Eiji;Minami Masayuki;Hibino Etsuhisa;Tani Tomonori;Sakakibara Jyunichi;Yamada Naouki
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • The objective of this study is to estimate the distribution of a zone disturbed by excavation (EDZ) around tunnels that have been excavated at about 500 m depth in pre-Tertiary hard sedimentary rock. One of the most important tasks is to evaluate changes in the dynamic stability and permeability of the rock around the tunnels, by investigating the properties of the rock after the excavation. We performed resistivity and acoustic tomography using two boreholes, 5 m in length, drilled horizontally from the wall of a tunnel in pre-Tertiary hard conglomerate. By these methods, we detected a low-resistivity and low-velocity zone 1 m in thickness around the wall of the tunnel. The resulting profiles were verified by permeability and evaporation tests performed at the same boreholes. This anomalous zone matched a high-permeability zone caused by open fractures. Next, we performed resistivity monitoring along annular survey lines in a tunnel excavated in pre-Tertiary hard shale by a tunnel-boring machine (TBM). We detected anomalous zones in 2D resistivity profiles surrounding the tunnel. A low-resistivity zone 1 m in thickness was detected around the tunnel when one year had passed after the excavation. However, two years later, the resistivity around the tunnel had increased in a portion, about 30 cm in thickness, of this zone. To investigate this change, we studied the relationship between groundwater flow from the surroundings and evaporation from the wall around the tunnel. These features were verified by the relationship between the resistivity and porosity of rocks obtained by laboratory tests on core samples. Furthermore, the profiles matched well with highly permeable zones detected by permeability and evaporation tests at a horizontal borehole drilled near the survey line. We conclude that the anomalous zones in these profiles indicate the EDZ around the tunnel.

Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model (2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석)

  • Lee, Bok-Hee;Kim, Tae-Ki;Cho, Yong-Seung;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

Estimation of Grounding Resistance by Correlation Analysing Change Factors of Soil Resistivity and Grounding Resistance (토양환경 변화와 접지저항의 상관관계 분석을 통한 접지 저항값 예측 연구)

  • Choi, Sun-Kyu;Lee, Kyu-Young;Moon, Young-Ho;Shim, Keon-Bo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2020
  • The purpose of this paper is to improve the grounding point measurement method for the maintenance of the earth resistance of the distribution line. This study defines the correlation among humidity of the soil, the earth resistivity and the grounding resistance. Based on the results of the study, the grounding resistance value measurement should be limited to the location where the earth resistivity change is large, and the measurement time and cost can be greatly reduced.

Electrical resistivity survey for evaluation of reinforced region by cement grouting in dike (전기비저항 수직탐사를 이용한 저수지 그라우팅 구간 평가)

  • 송성호;장의웅;김진호;김진성;김진춘
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.63-73
    • /
    • 2002
  • To evaluate reinforced region of dike by cement grouting, we investigated both the electrical resistivity and the strength of cement grout having various water-cement ratio with curing time. These investigation results showed that the electric conductivity of grout is much higher than that of water and that the apparent resistivity of grouted region is much lower than that of unoccupied region by grout. It was founded that electrical resistivity survey might be quite effective to detect grout region in dike. As the results of electrical resistivity sounding at three dikes, apparent resistivities after grouting showed several tens to several hundreds of ohm-m which were lower than those of pre-grouting and showed stabilizing trend with curing time. From these results, we could estimate that this behavior of apparent resistivity is due to increasing strength with curing time.