• 제목/요약/키워드: electric pulse

검색결과 638건 처리시간 0.027초

The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point (지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정)

  • Kim, Jae-Hyun;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제12권11호
    • /
    • pp.5123-5127
    • /
    • 2011
  • Research and development for the technology, that is about maintenance and accidents prevention of underground power distribution line, are demanding. The precise detection of leakage point of underground power line is very important, because it is difficult to detect the exact location of a fault in underground power line and to repair faults. When earth electric potential is measured to detect underground electric leakage point after transmitting AC electric pulse wave to underground power line, it must be measured in a specific half period of AC pulse wave because the distribution of the electric earth potential varies with the polarity of the transmitted wave. In this paper we proposed the measurement of half period modulated earth potential as a method to detect a underground leakage point. And We compared the proposed method with other methods. Through experiments we verified that the proposed method can be implemented and operated properly.

Study of PD Location in Generators by PD Pulses Propagation

  • Cheng, Yang-Chun;Li, Cheng-Rong;Wang, Wei
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.252-256
    • /
    • 2006
  • When a partial discharge takes place at the stator of a generator, the electrical pulse will propagate along the stator bars and the capacitor chains formed by the end part of the stator winds. On the first path, the pulse propagates as a travel wave at slow speed. On the second path, the pulse propagates at quick speed. Based on the data of the experiments on a real 50 MW steam generator, the author has found the pulses can propagate by magnetic field of the stator winding. It was studied that how to locating the partial discharge by signals coming from the different paths, including the features of signals on the two paths at time domain and frequency domain, the measurement frequency rang of the signals, the blind area, the advantage and disadvantage of this method.

Bearing Capacity of In-situ Pile Installed using Pulse Power (펄스파워를 이용한 현장타설말뚝의 지지력 특성)

  • Kim, Tae-Hoon;Chai, Soo-Geun;Jeong, Gyu-Geom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.521-527
    • /
    • 2005
  • In the past decades, complain about ground vibration and noise induced by pile driving has been quickly increased. Because of that, auger drilled piling methods have frequently used specially in urban area. However, the present auger drilled piling methods induce inevitable ground disturbance as well as a certain degree of vibration and noise due to the final hammering. For these reasons, a new auger drilled piling method is required to be developed. This paper introduces PDT(Pulse Discharge Technology) piling method and presents the characteristics of bearing capacity. The PDT piling method is to install in-situ piles using electric power so called Pulse. The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently.

  • PDF

Effects of Electric Heating Pad on Abdominal Pain and Anxiety during the Colonoscopy (복부가온패드 적용이 대장내시경 검사 대상자의 통증과 불안에 미치는 영향)

  • Kwon, Tae Jeong;Lee, Hyang Yeon;Lee, Jia
    • Journal of Korean Clinical Nursing Research
    • /
    • 제14권2호
    • /
    • pp.47-57
    • /
    • 2008
  • Purpose: The purpose of this study was to examine the effects of an electric heating pad on abdominal pain and anxiety during the colonoscopy procedure. Method: Data were collected from 70 adult patients (experimental group (35), control group (35)) who underwent colonoscopy in a general hospital in Seoul, South Korea between January 6 and May 4 2006. For the experimental group the electric heating pad was applied from 20 minutes before the test through the whole procedure. Objective pain was measured during the test, and subjective pain, state anxiety, blood pressure and pulse rate were measured after the procedure. Results: The experimental group with the electric heating pad reported significantly lower subjective pain and anxiety than did the control group. There were no significant differences in objective pain between experimental and control groups. Patients with an electric heating pad showed significantly lower systolic and diastolic pressure than did those in the control group. There was no significant difference in pulse rate between the groups. Conclusion: Use of an electric heating pad was efficient in reducing subjective pain and anxiety among patients undergoing colonoscopy. This is a convenient and useful nursing intervention to reduce anxiety and pain among patients having a colonoscopy.

  • PDF

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제29권11호
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

A Study on the Switching and Retention Characteristics of PLT(5) Thin Films (PLT(5) 박막의 Switching 및 Retention 특성에 관한 연구)

  • Choi Joon Young;Chang Dong Hoon;Kang Seong Jun;Yoon Yung Sup
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(2)
    • /
    • pp.367-370
    • /
    • 2004
  • We fabricated PLT(5) thin film on $Pt/TiO_x/SiO_2/Si$ substrate by using sol-gel method and investigated leakage current, switching and retention properties. The leakage current density of PLT(5) thin film was $3.56{\times}10^{-7}A/cm^2$ at 4V. In the examination of switching properties, pulse voltage and load resistance were $2V{\~}5V$ and $50{\Omega}{\~}3.3k{\Omega}$, respectively. Switching time had a tendency to decrease from 520ns to 140ns with the increase of pulse voltage, and also the time was increased from 140ns to $13.7{\mu}s$ with the increase of load resistance. The activation energy obtained from the relation of applied pulse voltage and switching time was about 143kV/cm. The error of switched charge density between hysteresis loop and experiment of polarization switching was about $10\%$. Also, polarization in retention was decreased as much as about $8\%$ after $10^5$s.

  • PDF

Analysis of Pulse Width Modulation Schemes for Electric Vehicle Power Converters (전기차용 전력변환장치의 펄스 폭 변조 기법 분석)

  • Quach, Ngoc-Thinh;Chae, Sang Heon;Kim, Eel-Hwan;Yang, Seung-Yong;Boo, Chang-Jin;Kim, Ho-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제65권12호
    • /
    • pp.2225-2231
    • /
    • 2016
  • In order to overcome the problem of fossil fuel energy, electric vehicle (EV) has been used in recent years. The important issues of EV are driving distance and lifetime related to EV efficiency. A voltage source converter is one of the main components of EV which can be operated with various pulse width modulation (PWM) schemes such as continuous PWM schemes and discontinuous PWM schemes. These PWM schemes will cause the effects on the efficiency of converter system and the lifetime of EV. Therefore, this paper proposes an analysis of the PWM schemes for the power converter on the EV. The objective is to find out a best solution for the EV by comparing the total harmonic distortion (THD) and transient response between the various PWM schemes. The operation of traction motor on the EV with the PWM schemes will be verified by using Psim simulation program.

Electrofusion of Tobacco and Pea Protoplasts (전기장하에서의 담배 및 완두 원형질체 융합)

  • 서정우
    • Journal of Plant Biology
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 1986
  • Intra- and inter-specific protoplast fusion of tobacco (Nicotiana tabacum cv. Virginia 115) and pea (Pisum sativum cv. Sparkle) were carried out in highly inhomogeneous alternating electric fields. Under the electric field of alternating current (AC, sine wave), 600 V/cm and 800 kHz for tobacco protoplast, and 600 V/cm and 700 kHz for pea protoplasts, the protoplasts were aggregated in pearl chains. Intra-specific protoplast fusions were most effectively induced within the aggregates of tobacco and pea, respectively, by the additional application of a single high field pulse of direct current (DC, square wave) at 1 kV/cm for 50 $mutextrm{s}$. Inter-specific fusions between protoplasts of the two plants were most effectively induced in the electric field of 600 V/cm and 700 kHz, and square wave pulse at 1 kV/cm for 50 $mutextrm{s}$. The duration of the pulse over the electrical breakdown voltages was simulated from 1 to 100 $mutextrm{s}$ in both tobacco and pea protoplast. The yield of the electrofusion products was significantly high (above 60%), compared with that (20%) of the standard fusion method by polyethylene glycol (PEG) 4,000, and the viability of electrofused protoplasts was above 70%, but that of PEG-fused protoplasts 8~16%, when determined by Evan's blue staining method.

  • PDF

Effects of Electric Current Stimuli and High-Voltage Electric Field Treatments on Brown Rice Germination (전류자극 및 전기장 처리가 현미 발아에 미치는 영향)

  • Lim, Ki-Taek;Kim, Jang-Ho;SeonWoo, Hoon;Hong, Ji-Hyang;Chung, Jong-Hoon
    • Journal of Biosystems Engineering
    • /
    • 제35권2호
    • /
    • pp.100-107
    • /
    • 2010
  • This study was conducted to investigate the effects of electric current stimuli and high-voltage electric field treatments on brown rice germination. The brown rice stimulated by electrical current stimuli, functional electrical stimuli of a pulse type, and high-voltage electric field treatments were observed (Type I, II and III). Treatment Type I was a method of semi-soaking brown rice with electric current stimuli of 0.13 V/cm, 0.19 V/cm, and 0.25 V/cm into Petri-dishes for 72 hours. Type II was a method of semi-soaking brown rice with functional electrical stimuli of a pulse type(DC 1 V, 1 Hz, 5%, and duty cycles of 5%, 20%, and 35%) into Petri-dishes for 72 hours. Type III was a method of water-soaking with high-voltage electric field treatments for 60 hours. High-voltage electric field treatments at 15 kV/cm were also conducted for 2.5 min, 7.5 min, and 10 min, respectively. The germination rate and the sprout growth of brown rice germinated by electric current stimuli with 0.13 V/cm, 0.19 V/cm, and 0.25 V/cm were increased by about 10-15% compared with those of the control group. The germination rate and the sprout growth of brown rice germinated by functional electrical stimuli of pulse type(DC 1 V, 1 Hz, 5% duty cycle) were increased by about 10∼15% compared to those of the control group. Also, the best effective treatment among high-voltage electric field treatments was the 10 min group at 15 kV/cm. The germination rate and the sprout growth of brown rice germinated by this treatment of 10 min at 15 kV/cm were increased by about 10∼20% compared to those of the control group. The treatments of electric current stimuli and high-voltage electric field accelerated the germination rate and sprout growth of brown rice by about 10∼15% compared to those of the control group.