• 제목/요약/키워드: electric power plant

검색결과 947건 처리시간 0.022초

Priority Rankings of the System Modifications to Reduce Core Damage Frequency of Wolsong NPP Units 2/3/4

  • Kwon, Jong-Jooh;Kim, Myung-Ki;Seo, Mi-Ro;Hong, Sung-Yull
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.899-905
    • /
    • 1998
  • The analysis priority makings the recommendation to reduce the total core damage frequency (CDF) of Wolsong nuclear Power Plant nits 2/3/4 was Performed in this paper. In order to derive the recommendation, the sensitivity analysis of CDF on which major contributors effect m performed based on the accident quantification results during Level 1 Probabilistic safety assessment (PSA). Priorities were ranked in tile way that compares the CDF reduction rate with efforts required to implement those recommendations using risk matrix

  • PDF

울릉도 풍력발전 계통연계 문제점 및 대책 (Technical Problems and solution based on Connection of Ullung Wind Power Plant into Power Distribution System)

  • 윤기갑;이완수;김병한;이상길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.305-307
    • /
    • 2001
  • The wind power equipment of Ullung island is composed of a hybride type of wind powers and diesel generators. The wind power generation in Ullung island is, howerever, not smooth due to the small capacity and weekness of existing power systems and line. Therefore, it is the purpose of this study to describe the technical problems and its solution through the investigation of actual conditions.

  • PDF

한경 풍력발전설비의 전력 수급 기여도 분석 (Contribution Analysis of Electric Power Supply on Jeju Han-Kyung Wind Power Plants)

  • 강지윤;김세호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.22-24
    • /
    • 2008
  • Construction of wind power plant is rapidly increasing since Jeju is known as the most suitable regarding wind power plants in Korea. But implementing wind power generation inevitably introduces new challenges due to its intermittent nature. In the paper, it is introduced the influence analysis and Han-Kyung wind power plants contribution on Jeju power system.

  • PDF

1kW 고체산화물 연료전지(SOFC) 시스템 설계 및 자열운전 (Design and Self-sustainable Operation of 1 kW SOFC System)

  • 이태희;최진혁;박태성;유영성;남석우
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.384-389
    • /
    • 2009
  • KEPRI (Korea Electric Power Research Institute) has studied planar type solid oxide fuel cell (SOFC) stacks using anode-supported cells and kW class co-generation systems for residential power generation. In this work, a 1 kW SOFC system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a SOFC stack made up of 48 cells, a fuel reformer, a catalytic combustor, and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation in that system. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. When the 1 kW SOFC stack was tested using hydrogen at $750^{\circ}C$, the stack power was about $1.2\;kW_e$ at 30 A and $1.6\;kW_e$ at 50 A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_e$ with hydrogen and $1.2\;kW_e$ with city gas respectively. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water.

고주파 가열 장비를 활용한 터빈로터 휨 교정수식모델 개발 (Development of Turbine Rotor Bending Straightening Numerical Model using the High Frequency Heating Equipment)

  • 박준수;현중섭;박현구;박광하
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.269-275
    • /
    • 2021
  • The turbine rotor, one of the main facilities in a power plant, it generates electricity while rotating at 3600 RPM. Because it rotates at high speed, it requires careful management because high vibration occurs even if it is deformed by only 0.1mm. However, bending occurs due to various causes during turbine operating. If turbine rotor bending occurs, the power plant must be stopped and repaired. In the past, straightening was carried out using a heating torch and furnace in the field. In case of straightening in this way, it is impossible to proceed systematically, so damage to the turbine rotor may occur and take long period for maintenance. Long maintenance period causes excessive cost, so it is necessary to straighten the rotor by minimizing damage to the rotor in a short period of time. To solve this problem, we developed a turbine rotor straightening equipment using high-frequency induction heating equipment. A straightening was validated for 500MW HIP rotor, and the optimal parameters for straightening were selected. In addition, based on the experimental results, finite element analysis was performed to build a database. Using the database, a straightening amount prediction model available for rotor straightening was developed. Using the developed straightening equipment and straightening prediction model, it is possible to straightening the rotor with minimized damage to the rotor in a short period of time.

고농도 초미세먼지 출현 시 발전소 주변 대기 입자 성장 및 화학조성 특성 (Characteristics of Particle Growth and Chemical Composition of High Concentrated Ultra Fine Dusts (PM2.5) in the Air around the Power Plant)

  • 강수지;성진호;엄용석;천성남
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.103-110
    • /
    • 2022
  • Ultrafine Particle number and size distributions were simultaneously measured at rural area around the power plant in Dangjin, South Korea. New Particle formation and growth events were frequently observed during January, 2021 and classified based on their strength and persistence as well as the variation in geometric mean diameter(GMD) on January 12, 21 and 17. In this study, we investigated mechanisms of new particle growth based on measurements using a high resolution time of flight aerosol mass spectrometer(HR-ToF-AMS) and a scanning mobility particle sizer(SMPS). On Event days(Jan 12 and 21), the total average growth rate was found to be 8.46 nm/h~24.76 nm/hr. These growth rate are comparable to those reported for other urban and rural sites in South Korea using different method. Comparing to the Non-Event day(Jan 17), New Particle Growth mostly occurred when solar radiation is peaked and relative humidity is low in daytime, moreover enhanced under the condition of higher precusors, NO2 (39.9 vs 6.2ppb), VOCs(129.5 vs 84.6ppb), NH3(11 vs 4.7ppb). The HR-ToF-AMS PM1.0 composition shows Organic and Ammoniated nitrate were dominant species effected by emission source in domestic. On the other hand, The Fraction of Ammoniated sulfate was calculated to be approximately 16% and 31% when air quality is inflow from China. Longer term studies are needed to help resolve the relative contributions of each precusor species on new particle growth characteristics.

음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구 (In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.315-322
    • /
    • 2008
  • 발전소 밸브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 밸브 시트(seat)면의 이물질 삽입, 시트의 균열, 스템(stem) 패킹(parking) 또는 용접부위 결함 및 피로균열 둥에 의해 누설손상이 발생하고 있다. 이러한 밸브 내부누설 상태를 정밀하게 진단하고 평가하기 위해서는 음향방출기술의 적용이 필요하며, 본 논문은 현장적용이 가능한 연구를 수행하고 그 결과를 소개하고자 한다. 또한 실제 발전소에서 운전되는 다양한 밸브 조건을 토대로 실험실 실험에 의해 주변잡음, 밸브누설시의 음향레벨 및 스펙트럼 특성을 분석하고, 발전소 현장실험 결과와의 비교분석을 통하여, 밸브 누설상태에 따른 주변잡음, 음향신호 및 측정 가능한 최소 누설검출량 등의 평가방법에 대해 고찰하였다. 실험실 실험 및 현장적용 연구결과로부터 밸브누설 여부를 포함한 상태 평가와 최소 측정가능 누설검출량 평가가 가능하였으며, 향후 본 연구는 발전설비 안전운전과 밸브누설로 인한 에너지 손실 예방에 크게 기여할 것으로 기대된다.

서인천 복합화력 발전소의 PSS 파라메터 Tuning (Field test Results for PSS Parameter Tuning in Seo-Incheon Power Plant)

  • 신정훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1143-1146
    • /
    • 1998
  • Static excitation systems with high gain and fast response times greatly aid transient stability. but at the same time tend to reduce small signal stability. The objective of the power system stabilizer(PSS) control is to provide a positive contribution to damping of the generator rotor angle swings, which are in a broad range of frequencies in the power system. Therefore, this paper shows the field test results for the GE's EX2000 PSS tuning on units at Seo-Incheon power plant. The test is to verify that the PSS response meets GE's design, criteria. The responses of generator terminal voltage, active power, field voltage and current were analyzed and PSS gain was tuned by 10 finally.

  • PDF

발전소 온배수의 수력에너지 개발에 관한 연구 (A Study on Hydro Energy Development of Discharged Cooling Water at the Power Plant)

  • 강금석;이대수;김지영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.813-818
    • /
    • 2005
  • Cooling seawater of thermal power plant which amounts about 5 cms per 100 MWe has hydro energy of about 3,000 kW at the thermal power plant complex, but this useful hydro energy has not been developed. Therefore, the feasibility study on hydro energy development of three power plants located in the southern and western coast of Korea was performed. Three target power plants are Samcheonpo, Boryeong and Hadong thermal power plant. The design head to discharge cooling water by gravity and the head caused by tidal level in the southwestern coastal area, could be used for the production of electric power. The various alternatives were studied and technical feasibility and economical efficiency were clearly proved.

  • PDF

Development of a Power Plant Simulation Tool with GUI based on General Purpose Design Software

  • Kim Dong Wook;Youn Cheong;Cho Byung-Hak;Son Gihun
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권3호
    • /
    • pp.493-501
    • /
    • 2005
  • A power plant simulation tool ('PowerSim') has been developed with 10 years experience from the development of a plant simulator for efficient modeling of a power plant. PowerSim is the first developed tool in Korea for plant simulation with various plant component models, instructor station function and the Graphic Model Builder (GMB). PowerSim is composed of a graphic editor using general purpose design software, a netlist converter, component models, the scheduler, Instructor Station and an executive. The graphic editor generates a netlist that shows the connection status of the various plant components from the Simdiagram, which is drawn by Icon Drag method supported by GUI environment of the PowerSim. Netlist Converter normalizes the connection status of the components. Scheduler makes scheduling for the execution of the device models according to the netlist. Therefore, the user makes Simdiagram based on the plant Pipe and Instrument Drawing (P&ID) and inputs the plant data for automatic simulating execution. This paper introduces Graphic Model Builder (GMB), instructor station, executive and the detailed introduction of thermal-hydraulic modeling. This paper will also introduce basic ideas on how the simulation Diagram, based on netlist generated from general purpose design software, is made and how the system is organized. The developed tool has been verified through the simulation of a real power plant.