• 제목/요약/키워드: electric power plant

검색결과 947건 처리시간 0.032초

A Two-Dimensional Study of Transonic Flow Characteristics in Steam Control Valve for Power Plant

  • Yonezawa, Koichi;Terachi, Yoshinori;Nakajima, Toru;Tsujimoto, Yoshinobu;Tezuka, Kenichi;Mori, Michitsugu;Morita, Ryo;Inada, Fumio
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권1호
    • /
    • pp.58-66
    • /
    • 2010
  • A steam control valve is used to control the flow from the steam generator to the steam turbine in thermal and nuclear power plants. During startup and shutdown of the plant, the steam control valve is operated under a partial flow conditions. In such conditions, the valve opening is small and the pressure deference across the valve is large. As a result, the flow downstream of the valve is composed of separated unsteady transonic jets. Such flow patterns often cause undesirable large unsteady fluid force on the valve head and downstream pipe system. In the present study, various flow patterns are investigated in order to understand the characteristics of the unsteady flow around the valve. Experiments are carried out with simplified two-dimensional valve models. Two-dimensional unsteady flow simulations are conducted in order to understand the experimental results in detail. Scale effects on the flow characteristics are also examined. Results show three types of oscillating flow pattern and three types of static flow patterns.

인버터 DSM 프로그램 보급과 시장 전망 (Evaluation of Inverter DSM Program in KEPCO and Market Diffusion)

  • 이학주;박재덕;김용진;이수목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.370-371
    • /
    • 2006
  • The electric demand increase, financial need for new power plant constructions and environmental problem have led to search for more efficient energy Production and energy conservation technology. To minimize the construction of power plants and reduce total power consumption include installation of inverters to motors used for pumps and fans. However, the high price of inverters is the biggest obstacle to their wide use. Accordingly, to maximize the effect of energy saving by the expanded use of inverters, governmental economic support as ell as the analysis of energy saving effect. his paper presents he present state analysis of inverter DSM program and propose he improvement for activation of inverter DSM program.

  • PDF

Study on the Fire Hazard and Risk Analysis Derived from the Plant Configuration Change During the Shutdown Period at Nuclear Power Plants

  • Jee Moon-Hak;Hong Sung-Yull;Sung Chang-Kyung;Jung Hyun-Jong
    • Nuclear Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.547-555
    • /
    • 2003
  • Fire hazard and risk analysis at Nuclear Power Plants is implemented on the basis of the normal operational configuration. This steady configuration, however, can be changed due to the temporary displacement of equipment, electric cable and irregular movement of workers through the fire compartments when the on-line maintenance is processed during the power operation mode or the scheduled outage mode for the refueling. With the consequence of this configuration change, the fire analysis condition and the evaluation result will be different from those that were analyzed based on the steady configuration. In this context, at this paper, the general items for the reassessment are categorized when the configuration has changed. The contemporary zone models for the detail fire analysis are also illustrated for their application for each classified condition.

인버터 DSM 프로그램의 경제성평가 (Economic Analysis of Inverter DSM Program for Inverter)

  • 이학주;권성철;최병윤;이승윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.521-523
    • /
    • 2001
  • The electric demand increase, financial need for new power plant constructions and environmental problem have led to search for more efficient energy production and energy conservation technology. To minimize the construction of power plants and reduce total power consumption include installation of inverters to motors used for pumps and fans. However, the high price of Inverters is the biggest obstacle to their wide use. Accordingly, to maximize the effect of energy saving by the expanded use of inverters, governmental economic support as well as the analysis of energy saving effect. This paper presents the cost-effectiveness analysis for DSM program evaluation and case study to analyze inverter DSM program.

  • PDF

Preventing cascading failure of electric power protection systems in nuclear power plant

  • Moustafa, Moustafa Abdelrahman Mohamed Mohamed;Chang, Choong-koo
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.121-130
    • /
    • 2021
  • Cascading failure is the main cause of large blackouts in electrical power systems; this paper analyzes a cascading failure in Hanbit nuclear power plant unit two (2) caused by a circuit breaker (CB) operation failure. This malfunction has been expanded to the loss of offsite power (LOOP). In this study, current practices are reviewed and then the methodologies of how to prevent cascading failures in protection power systems are introduced. An overview on the implementation of IEC61850 GOOSE messaging-based zone selective interlocking (ZSI) scheme as key solution is proposed. In consideration of ZSI blocking time, all influencing factors such as circuit breaker opening time, relay I/O response time and messages travelling time in the communication network should be taken into account. The purpose of this paper is to elaborate on the effect of cascading failure in NPP electrical power protection system and propose preventive actions for this failures. Finally, the expected advantages and challenges are elaborated.

전원공급기 점검장치 개발 (Development of Power Supply Testing System)

  • 박종범;김영화;이해규;이낙희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.703-705
    • /
    • 1999
  • The Power supplies used commonly in the Nuclear, Thermal and Hydraulic Power Plant are required to test the function and reliabilities. For the better contribution of reliable operation and speedy maintenance of Power Plant, it is necessary to gather and analyze the datum, to print out the result of testing using PC and proper controllers. Various kinds of power supply shall be tested and examined automatically. By storing the test results in the Database it is possible to find out the changing of characteristics of power supplies. So it is very useful to prevent any problems that may occur in the power supplies.

  • PDF

가스터빈 시송전 발전기 여자시스템에 관한 연구 (A Study of Generator Excitation System for first Power Supply to gird line)

  • 류호선;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1193-1194
    • /
    • 2011
  • We performed commissioning of redundant digital excitation system for gas turbine generator. One of its issues is first power supply test to gird line when it was compared with the other commissioning. If blackout will be happened, a few of start power plants must supply power to grid line. And then generator must increase voltage and real power slowly for line charge. The trial product was installed and successfully operated at a 100MW power plant after commissioning.

  • PDF

원자력발전소 비상디젤발전기 상태감시를 위한 운전인자 선정에 관한 연구 (Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant)

  • 박종혁;최광희;이상국;박종은
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.3-8
    • /
    • 2007
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear reactor at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the plant safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to maintain and monitor and forecast the reliability level of diesel generator. To do this kind of diesel generator condition monitoring we reviewed several operating factors and history of the wolsong unit 3 diesel generator and selected the proper conditioning monitoring operating factors.

  • PDF

ASSESSMENT OF POSSIBILITY OF PRIMARY WATER STRESS CORROSION CRACKING OCCURRENCE BASED ON RESIDUAL STRESS ANALYSIS IN PRESSURIZER SAFETY NOZZLE OF NUCLEAR POWER PLANT

  • Lee, Kyoung-Soo;Kim, W.;Lee, Jeong-Geun
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.343-354
    • /
    • 2012
  • Primary water stress corrosion cracking (PWSCC) is a major safety concern in the nuclear power industry worldwide. PWSCC is known to initiate only in the condition in which sufficiently high tensile stress is applied to alloy 600 tube material or alloy 82/182 weld material in pressurized water reactor operating environments. However, it is still uncertain how much tensile stress is re-quired to generate PWSCC or what causes such high tensile stress. This study was performed to pre-dict the magnitude of weld residual stress and operating stress and compare it with previous experi-mental results for PWSCC initiation. For the study, a pressurizer safety nozzle was selected because it is reported to be vulnerable to PWSCC in overseas plants. The assessment was conducted by nu-merical analysis. Before performing stress analysis for plant conditions, a preliminary mock-up ana-lysis was done. The result of the preliminary analysis was validated by residual stress measurement in the mock-up. After verification of the analysis methodology, an analysis under plant conditions was conducted. The analysis results show that the stress level is not high enough to initiate PWSCC. If a plant is properly welded and operated, PWSCC is not likely to occur in the pressurizer safety nozzle.

발전소 주변해역 식물플랑크톤의 군집 특성 (Characteristics of Phytoplankton Communities in the Coastal Waters of Power Plant)

  • 강연식
    • ALGAE
    • /
    • 제23권1호
    • /
    • pp.31-52
    • /
    • 2008
  • This study analyzes characteristics of phytoplankton communities around Wolseong nuclear power plant by selecting 16 stations from July 2006 to June 2007 and understands the influences on standing crops and chlorophyll a of phytoplankton by passing through the cooling water system. The total species number is 283, among which diatoms is 208 occupying 73.5% of total taxa. The mean of total standing crops is 469,380-3,704,114 cells L-1. It is the highest in April 2007 because blooming of Chaetoceros socialis occurs during this period. The mean standing crops of microplankton and nanoplankton are average 129,666-3,392,640 cells L-1 and 240,943-650,505 cells L-1 respectively, which occupy 54.01% and 46.54% of total standing crops. The mean concentrations of total chlorophyll a is 0.64-5.39 μg L-1. The mean concentrations of chlorophyll a of microplankton, nanoplankton and picoplankton are 1.33 μg L-1, 0.21 μg L-1 and 0.49 μg L-1 respectively. Dominant species around Wolseong neclear power plant during this study are Chaetoceros debilis, Chaetoceros socialis, Leptocylindrus danicus, Pseudo-nitzschia fraudulenta, P. subfraudulenta and Thalassiosira decipiens. Fluctuation rates of standing crops and chlorophyll a concentrations of phytoplankton passing through the cooling water system are 22.80% and 50.48% respectively. Decrease of standing crops and chlorophyll a concentrations of phytoplankton means that community structure of phytoplnakton may change at the discharge areas.