• Title/Summary/Keyword: electric power cooperation

Search Result 223, Processing Time 0.028 seconds

Analysis of Return Current by Common Earth on Electrical Line of the Gyeongbu Line (경부선 전철화 구간에서의 공동접지에 의한 귀선전류 분석)

  • Kim, Yong-Kyu;Baek, Jong-Hyen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4968-4974
    • /
    • 2010
  • Electrical Railroads provide electric power, which can operate vehicles, via feeder wires. And the supplied current returns to the transformer substation through lines and ground net. In domestic cases, the configuration of ground net affecting such a return current mostly uses an exclusive earth method. However, along with the introduction to Gyeongbu HSL(High Speed Line), the concept of Common Earth was applied to Electrical Railroads. In this paper, based on the return currents analyzed to be measured in the electrified sections for the operation of High Speed Rails in existing lines, we analyze the relations between earth methods and return currents in electrified sections. For analysis, we utilize the measured values of return currents measured in track circuits in Gyeongbu HSL, and predictive values of those compared to the earth methods between Gyeongbu HSL and the existing electrified sections.

A Study on the Manufacture and Application of UV-Cured Multi-Functional(Anti-Stain/Virus) Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 복합기능(내오염/항균)성 코팅액의 제조 및 응용에 관한 연구)

  • Yoon, Hyun-Jung;Park, Bo-Ram;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3615-3620
    • /
    • 2010
  • This study is development of UV-cured coating compounds which has more improved anti-stain and anti-biosis, about surface prevention of PVC Tile. We added water-soluble anti-static and anti-microbial agent to the resin. The process has prevented electrostatic and bacterial contagious disease. The result, which added 15wt% of water-soluble anti-static and 1wt% anti-microbial agent and coated with No.12 Bar-coater, coating composition had optimum surface property. It appear electric resistance($10^9{\Omega}/cm^2$), anti-stain (Ink Test, Dust Test), anti-biosis (99.99%), and adhesive power(100%).

Forecasting of Heat Demand in Winter Using Linear Regresson Models for Korea District Heating Corporation (한국지역난방공사의 겨울철 열수요 예측을 위한 선형회귀모형 개발)

  • Baek, Jong-Kwan;Han, Jung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1488-1494
    • /
    • 2011
  • In this paper, we propose an algorithm using linear regression model that forecasts the demand of heated water in winter. To supply heated water to apartments, stores and office buildings, Korea District Heating Corp.(KDHC) operates boilers including electric power generators. In order to operate facilities generating heated water economically, it is essential to forecast daily demand of heated water with accuracy. Analysis of history data of Kangnam Branch of KDHC in 2006 and 2007 reveals that heated water supply on previous day as well as temperature are the most important factors to forecast the daily demand of heated water. When calculated by the proposed regression model, mean absolute percentage error for the demand of heated water in winter of the year 2006 through 2009 does not exceed 3.87%.

A Study of Parallel Operation of Module Power using CAN Communication (CAN통신을 이용한 모듈전원의 병렬운전에 관한 연구)

  • Park, Seong-Mi;Lee, Sang-Hyeok;Park, Sung-Jun;Lee, Bae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3603-3609
    • /
    • 2011
  • In this paper, we proposes new load-sharing algorism for equal current division using CAN communication. Proposed algorithm is different from conventional analog method, it performed strong Load-sharing using bi-direction high speed communication. Each modules constitution on independence controller (voltage controller, electric current controller). In parallel system prototype, each module have controller and performed load-sharing according to master module integral value. Also additional controller use for getting each module situations that fault situation of module and fault locate of module. we implemented high efficient load-sharing and redundancy. In this paper, we verify the validity of proposed algorithm using PSIM program and prototype.

A Study on Optimal Operation Method of Multiple Microgrid System Considering Line Flow Limits (선로제약을 고려한 복수개의 마이크로그리드 최적운영 기법에 관한 연구)

  • Park, Si-Na;An, Jeong-Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.258-264
    • /
    • 2018
  • This paper presents application of a differential search (DS) meta-heuristic optimization algorithm for optimal operation of a micro grid system. The DS algorithm simulates the Brownian-like random-walk movement used by an organism to migrate. The micro grid system consists of a wind turbine, a diesel generator, a fuel cell, and a photovoltaic system. The wind turbine generator is modeled by considering the characteristics of variable output. Optimization is aimed at minimizing the cost function of the system, including fuel costs and maximizing fuel efficiency to generate electric power. The simulation was applied to a micro grid system only. This study applies the DS algorithm with excellence and efficiency in terms of coding simplicity, fast convergence speed, and accuracy in the optimal operation of micro grids based on renewable energy resources, and we compared its optimum value to other algorithms to prove its superiority.

A study on the composition of piezoelectric ceramic for high-power piezoelectric transformer (고출력 압전 변압기용 압전 세라믹의 조성에 관한 연구)

  • Lee, Jong-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.390-395
    • /
    • 2011
  • In order to develope piezoelectric transformer for the ballast of fluorescent lamp, the composition of piezoelectric ceramics was 0.95Pb($Zr_xTi_{1-x}$)O3+yPb($Mn_{1/3}Nb_{2/3}$)$O_3$+(0.05-y)Pb($Sb_{1/2}Nb_{1/2}$)$O_3$. PMN compound was selected to improve mechanical quality factor and PSN to prevent the decrease of dielectric constant and electromechanical coupling coefficient. Dielectric and piezoelectric characteristics in the region of MPB of 0.95Pb($Zr_xTi_{1-x}$)$O_3$+yPb($Mn_{1/3}Nb_{2/3}$)$O_3$+(0.05-y)Pb($Sb_{1/2}Nb_{1/2}$)$O_3$ ceramics was discussed both quantatively and qualitatively.

Design of Idle-time Measurement System for Data Spoofing Detection (데이터 스푸핑 탐지를 위한 유휴 시간 측정 시스템 설계)

  • Jung, Sung-Mo;Song, Jae-Gu;Kim, Tai-Hoon;So, Yo-Hwan;Kim, Seok-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.151-158
    • /
    • 2010
  • The industrial foundation of the inside and outside of a country has brought significant damages due to attacks from hackers. Especially, if the national primary core infrastructures(like electric power, dam, railroad, atomic energy, etc.) has been significantly damaged, it can be directly linked not only to economic problems but also to people's lives. These national primary core infrastructures usually constitute SCADA system using Modbus RS486 communication. Because of this characteristic, SCADA system has RTU master and slave linked to RJ11 cables to directly pass commands. RJ11 is possible in data spoofing using physical connection because the transmission range of RJ11 has a wide bandwidth(almost 1km). Hence, this paper designed an idle-time measurement system for SCADA system for emerging security improvement in the national primary core infrastructures.

Battery Pack of Elastically Adhering Protection Circuit Module (보호회로가 탄성적으로 부착된 전지 팩)

  • Cho, Kyeung-Ho;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1740-1749
    • /
    • 2009
  • As mobile devices evolve and digital convergence trend is here to stay, mobile phones are built with multiple functions including cameras, MP3s, TVs and game consoles. As a consequence, such multi-functional mobile phones come to spend more power, facilitating development of next-generation ultra-capacity lithium ion battery. In addition, environmental regulations and rising oil prices cause demand for hybrid cars to keep rising. Accordingly, more and more attention is being paid to medium and large batteries and more efforts are being made to realize lower battery prices, higher outputs and stability. This study presented a patent technology related to the lithium ion battery packing that allows reducing processes related, increasing productivity and recycling parts other than the body. The lithium ion battery pack to which protection circuits are elastically attached provides short circuit protection for the circuit and the body and makes electric connection of the circuit and the body easier.

Optimal Design Method of 1-Port Surge Protective Device Based on Zinc Oxide Varistor (선화아연바리스터 기반의 1-포트 서지보호장치의 최적 설계 기법)

  • Jeong, Tae-Hoon;Kim, Young-Sung;Park, Geun-Bo;Lee, Seung-IL
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.93-102
    • /
    • 2018
  • This paper reports a Surge Protective Device (SPD) that is used to protect an automatic metering interface (AMI) power supplies of communication equipment on a low-voltage distribution system from a lightning current. The surge protective device (SPD) can be classified as one-port SPDs and two-port SPDs with decoupling elements depending on the connection type. The protection of internal systems against the lightning current may require a systematic approach consisting of coordinated SPDs. To deal with this, the definition of a lightning protection zone (LPZ) was studied and interpreted through a theoretical review. Because the lightning current resulting from a lightning surge is considerably high, there is limited protection from one SPD; therefore, coordinated cascaded MOV-based SPDs are installed to solve this problem. Regarding the power grid mentioned in this paper, a class II SPD for the low-voltage distribution system installed on the border of LPZ1 and LPZ2, which establish a protection coordination with the Arrester (LA, SA) that corresponds to the LPZO installed on the MOF stage connected to one system were designed to protect various communication (control) equipment, including the automatic meter reading system inside the branch-type electric supply panel of a building, not the incoming side of one system. In addition, performance-related tests were done by a comparison with the existing method through testing, and the optimal design was achieved for the 1-port SPD that uses a series connection and can bleed load current without any decoupling element.

Analysis of Domestic and Foreign Electricity Rates based on Electricity Usage Patterns of AMI applied Apartments (AMI 적용 아파트의 전기사용 패턴 기반 국내외 전기요금제 분석)

  • Koo, In-Seok;Lee, Sung-Hee;Sohn, Joong-Chan;Rhie, Dong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.52-59
    • /
    • 2020
  • Currently, the domestic electricity rates for houses are charged by applying a progressive level according to monthly electricity usage. Electricity rates rise sharply wWhen the amount of electricity used is large, electricity rates rise sharply. The standardized electricity rate progressive system has limitations in that it lacks consideration of the consumers' power usage patterns and limits consumers' their options. Accordingly, the Ministry of Trade, Industry and Energy and the Korea Electric Power Corporation have been demonstrating the basis of a rate system for housing, which is a method of charging electricity according to the amount of electricity used by season and time. In this paper, 10 electricity usage patterns were derived through from AMI data analysis for 5 five years of 362 apartment complexes located in metropolitan cities. The patterns were, and then applied to the existing domestic electricity rate and time-by-time rates applied to demonstrations, and by time-by-time rates in the US and Australia. The effect of the optional rate by pattern was compared and analyzed. As a result, it was confirmed that benefits occurred in five5 patterns compared to existing rate plans, and the electricity rates increased in 5 five patterns, and t. This phenomenon shows the same phenomenon withis the same as the overseas rates, including domestic rates being demonstrated.