• 제목/요약/키워드: electric noise

검색결과 1,035건 처리시간 0.028초

가전제품의 소음 특성 (The Characteristics of the Noise of Electric Home Appliances)

  • 구진회;강대준;이재원;김태석;권혁제
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.332-339
    • /
    • 2007
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. The noise of a range hood is distributed over a wide range frequency. Lastly, we intented to propose the proper method measuring sound power level on each electric home appliance.

  • PDF

베어링 Electric Arcing 예지사례 (Case Study on Bearing Electric Arcing)

  • 전용상
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1076-1077
    • /
    • 2007
  • CMS(Condition Monitoring System) is a useful tool to predict the defect of machine condition, for example, Motor, Bearing, Gear, Fan, etc. And, recently CMS is very important on plant. In this paper, describe the bearing electric arcing with example.

  • PDF

765kV 송전선로용 특수 다중도체 방식의 코로나 잡음특성 및 전계분포 해석 (Analysis on Electric Field Distributions and Corona Characteristics of Special Conductor Bundles for 765kV Transmission Line)

  • 민석원;김용준;신구용;이동일;주문노;양광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.556-560
    • /
    • 2001
  • To solve aeolian noise, we have tried several special conductor bundles equipped with spiral rod and one kind of low aeolian noise conductor with a special shape. Charge simulation method was applied to analyze electric field distributions of them in transmission line and corona cage for investigating the corona characteristics. This paper describes the electric field distributions and the performances of audible noise and radio interference from the special bundles in 765 kV transmission line by using corona characteristics obtained from corona cage simulation.

  • PDF

초퍼 연산증폭기와 다수의 정합 트랜지스터를 이용한 수중 전기장 센서용 저잡음 전치 증폭기 설계 (Low-Noise Preamplifier Design for Underwater Electric Field Sensors using Chopper stabilized Operational Amplifiers and Multiple Matched Transistors)

  • 배기웅;양창섭;한승환;정상명;정현주
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.120-124
    • /
    • 2022
  • With advancements in underwater stealth technology for naval vessels, new sensor configurations for detecting targets have been attracting increased attention. Latest underwater mines adopt multiple sensor configurations that include electric field sensors to detect targets and to help acquire accurate ignition time. An underwater electric field sensor consists of a pair of electrodes, signal processing unit, and preamplifier. For detecting underwater electric fields, the preamplifier requires low-noise amplification at ultra-low frequency bands. In this paper, the specific requirements for low-noise preamplifiers are discussed along with the experimental results of various setups of matched transistors and chopper stabilized operational amplifiers. The results showed that noise characteristics at ultra-low frequency bands were affected significantly by the voltage noise density of the chopper amplifier and the number of matched transistors used for differential amplification. The fabricated preamplifier was operated within normal design parameters, which was verified by testing its gain, phase, and linearity.

측정방법별 가전제품의 음향파워레벨 (Sound Power Level of Electric Home Appliances according to Measurement Method)

  • 강대준;구진회;이재원
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.335-346
    • /
    • 2009
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. This results will help us predict the indoor noise level using the basic data of sound power level.

A Study on the Noise and Vibration Analysis of 200kW PMSM for Electric Propulsion Ship

  • Cho, Yang-Uk;Kang, Gyu-Hong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.389-393
    • /
    • 2014
  • This paper presents one of the methods for design to reduce the noise and vibration of 200kW motor for electric propulsion ship. One of the important factors affecting vibration of the motor is the resonance. The natural frequency and natural mode of the 200kW motor is analyzed by using FEM tool and impact test equipment to avoid the resonance. Also, compare FEM result with impact test result to make a reliable FE model of 200kW motor. In order to find out the effect of the noise and vibration of the motor by electromagnetic excitation force, conduct electromagnetic-structure coupled analysis. These characteristics are much useful to design 200kW motor for electric propulsion ship.

Some Way for Three-phase Induction Motors Electromagnetic Noise Reduction

  • Sarbu, Mircea A.
    • 소음진동
    • /
    • 제13권2호
    • /
    • pp.119-128
    • /
    • 2003
  • Abstract Increasing awareness of industrial noise pollution and emerging stricter standards have made noise an important topic of research in electric motors. The standard three-phase induction motors. see Fig. 1, (abbreviated further as TPIM) are mass-produced as being simple, robust and rather inexpensive, as opposed to other types of electric motors. Electric motors use over half of all electricity consumed in most countries. Typically motors consume 60∼80 % of the electricity for those used In the industrial sector and about 20∼35 % of the electricity for those used in the commercial sector. For that is important to know their participation to the noise pollution of the environment and the efficient ways of their noise reduction. Each step in determining the ways for TPIM electromagnetic noise reduction including the methods that highlight their efficiency, are presented and explained.

디젤전기기관차의 기관소음 특성 (Noise Properties of Diesel Electric Locomotive)

  • 이덕희;조준호;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.187-191
    • /
    • 2001
  • Diesel locomotive engine is the main source of train noise in these days but hard to reduce the level by barrier for it emitted from high location. For the passing high level noise properties of diesel locomotive engine, there are needs of changing the environmental railway limit to maximum level from equivalent. In this study we investigate the noise characteristics of the diesel electric locomotive according to the change of notch. From the result we found out the frequency of engine cycle noise and the shape of noise spectrum.

  • PDF

축소모형 실험을 이용한 전기적 잡음에 관한연구 (The Study on an Electric Noise Effect using Physical Scale Modeling)

  • 윤점동;송영수;소경묵
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.297-302
    • /
    • 2007
  • Recently, electrical resistivity survey is used in the various fields and applied to urban area with many electrical noises. Therefor it's necessary to observe the electrical noise effect of the geological structure. The physical scale modeling was conducted for measuring the electric noise effect of the two geological models at various distances, depths and diameters of the electric noise objects. The results are as following. 1. When conductive noise object was vertical to the strike of geological structure and moved to the strike direction, the effect of conductive noise object at various separated distances to the measurement line was disappeared at a half distance measurement line length regardless of electrode arrays. 2. When conductive noise object was vertical to the strike of geological structure and moved to the strike direction, the effect of conductive noise object at various depths was disappeared at 4unit apart from the measurement line regardless of electrode arrays. 3. When conductive noise object was vertical to the strike of geological structure and moved to the strike direction, the effect of conductive noise object at various diameters was disappeared at 4unit apart from the measurement line regardless of electrode arrays.

  • PDF

연료전지 자동차용 흡기 소음기의 설계 변수 최적화에 관한 연구 (Optimization of the Multi-chamber Perforated Muffler for the Air Processing Unit of the Fuel Cell Electric Vehicle)

  • 김의열;이상권
    • 한국소음진동공학회논문집
    • /
    • 제19권7호
    • /
    • pp.736-745
    • /
    • 2009
  • Fuel cells convert a fuel together with oxygen in a highly efficient electrochemical reaction to electricity and water. Since the electrochemical reaction in the fuel cell stack dose not generate any noise, Fuel cell systems are expected to operated much quieter than combustion engines. However, the tonal noise and the broad band noise caused by a centrifugal compressor and an electric motor cause which is required to feed the ambient air to the cathode of the fuel cell stack with high pressure. In this study, the multi-camber perforated muffler is used to reduce noise. We propose optimized muffler model using an axiomatic design method that optimizes the parameters of perforated muffler while keeping the volume of muffler minimized.