• 제목/요약/키워드: electric meter

검색결과 205건 처리시간 0.03초

MR 센서와 PIC를 이용한 비접촉식 정밀 유량계 개발에 관한 연구 (A Study on Development of a Noncontact Precision Flow-meter Using MR Sensor and PIC)

  • 이승희;이민철;고석조;장용석;최문호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1063-1066
    • /
    • 2003
  • A flow-meter and its measurement controller was developed for a hydraulic system. This study, for development of positive displacement flow-meter, consist of PIC(Peripheral Interface Controller) controller with MR(Magneto-resistive) sensors. This flow-meter is used valve position indicator for valve control system by hydraulic. The MR sensors are used for the rotation of OVAL gear that detecting device. In the ship environments, consideration that necessary explosive proof. Thus electro device or electro flow-meter needs explosion design for electric circuit. We designed noncontact type flow-meter and evaluated the safety and measuring abilities.

  • PDF

ANSI C12.22 국제 통신 프로토콜이 적용된 스마트미터 개발 (Development of a Smart meter Applying the ANSI C12.22 International Communication Protocols)

  • 이상일
    • 한국정보통신학회논문지
    • /
    • 제17권12호
    • /
    • pp.2952-2959
    • /
    • 2013
  • 본 논문에서는 국제 통신 프로토콜이 적용된 스마트미터를 개발하였다. 스마트미터는 전력 공급 사업자와의 데이터 교환을 위해 양방향 통신 및 제어 기술, 전기 기기의 등록 및 해제를 위한 통신 프로토콜이 요구된다. 스마트미터의 통신 프로토콜은 미국과 유럽을 중심으로 표준화가 진행되고 있으며, 본 논문에서 제안하는 스마트미터의 통신 프로토콜은 북미방식인 ANSI C12.22 표준을 채택하여 적용하였다. 스마트미터는 또한 전력 사용자에게도 실시간으로 소비 전력 정보와 요금 정보를 제공해야 하며, 사용자는 이 정보를 바탕으로 적절하게 수요반응을 할 수 있어야한다. 본 논문에서는 스마트미터에서 측정되는 전력량이 실시간으로 사용자에게도 보고될 수 있도록 하였으며, IHD(In Home Display)를 윈도우즈 소프트웨어로 구현하여 개발된 스마트미터와의 연동을 실현하였다.

원격검침 설비의 네트워크 상태감시를 위한 SNMP 기반의 저압 AMI 망관리시스템 개발 (Development of AMI NMS (Network Management System) using SNMP for Network Monitoring of Meter Reading Devices)

  • 김영일;박소정;김영준;정남준;최문석;박병석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.259-268
    • /
    • 2016
  • 한국전력공사는 200년부터 저압 고객에 대한 AMI (Advanced Metering Infrastructure) 기반의 검침시스템을 구축하여 운영하고 있다. 한전의 AMI 검침시스템은 현재 255만호에 설치되어 운영되고 있으며 2020년까지 2200만호를 설치하여 운영할 예정이다. 본 연구에서는 원활한 AMI 검침망 운영을 위해 DCU (Data Concentration Unit) 및 모뎀에 대한 네트워크 동작상태를 감시할 수 있는 AMI 망관리시스템을 개발하였다. AMI 망관리시스템은 네트워크 장비에 대한 속성 데이터 및 네트워크 토플로지 정보, 통신성능 정보, 장애정보 등을 수집하고, 데이터 분석을 통해 장애내역을 생성하며, 원격에서 장비를 제어하는 등의 기능을 제공하고 있다. AMI 망관리시스템은 전력선 통신망에서 네트워크 장비에 대한 약 370여개의 MIB (Management Information Base) 정보를 SNMP (Simple Network Management Protocol)를 이용하여 수집과 제어를 수행하고 있다. 본 논문에서는 AMI 망관리시스템에 대한 주요 기능과 설계내용, 구현된 서비스 화면을 소개하고자 한다.

상수도 자동 검침 시스템 구축에 관한 연구 : 부산 기장군과 김해시 사례를 중심으로 (Automatic Meter Reading System for Water-Supply)

  • 서창갑;박영재
    • 디지털융복합연구
    • /
    • 제7권3호
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we introduce automatic meter reading system for tap water. The system is composed of automatic meter, router using RF and CDMA network, and data server. This system will easily extend to fire detect, gas, and electric charge meter system. In addition, this system will be used to monitoring a water leak and human which live in solitude. Proposed system is installed at Gimhae-City and Gijang-gun. As a result of the automatic meter reading system for tap water, The leak of water and complain of user is decreased. But The building cost is still an obstacle to expand into entire city.

  • PDF

지리산산(智異山産) 일본 잎갈나무재(材)와 포플러재(材)의 단면별(斷面別) 평형함수율(平衡含水率)(EMC) 측정치(測定値)와 그 상관성(相關性) (Correlation between Determining Values of Sectional Equilibrium Moisture Contents of Larix leptolepis and Populus euramericana I - 476 grown in Mt. Jiri)

  • 황증;문창국
    • 한국산림과학회지
    • /
    • 제59권1호
    • /
    • pp.63-66
    • /
    • 1983
  • 일본잎갈나무(Larix leptolepis)오 포플러(Populus euamerieana I-476)에 대(對)하여 각(各) 함수율(含水率)을 각단면별(各斷面別) 전건법(全乾法)에 의(依)한 측정치(測定値)와 Electric Moisture Meter(Kett-M8A) 측정치(測定値)와 계산추정치간(計算推定値間)이 상관성(相關性)과 그 신뢰성(信賴性)을 조사(調査)하여 본바 일본잎갈나무재(材)에 있어서는 전건측정치(全乾測定値), Moisture Meter측정치(測定値), 계산추정식간(計算推定値間)에 모든 방향(方向)에 1~5% 수준(水準)의 높은 상관성(相關性)을 보였으나 포플러재(材)에 있어서는 전건측정치(全乾測定値)와 Moisture meter측정치간(測定値間)에 상관성(相關性)은 인정(認定)되나 여지(餘地)에서는 유의의(有意義)한 상관성(相關性)을 인정(認定)할 수 없었다.

  • PDF

On-Line 및 Off-Line 상태에 따른 누설 전류 진단 분석 (Analysis of Leakage Current Diagnosis According to Online and Offline Conditions)

  • 한경철;이경섭;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.261-266
    • /
    • 2018
  • When the clamp meter approaches the electric path where current is flowing, leakage current can be measured at a distance from the electric current because the induced current increases as the magnitude of the current increases and approaches nearer to the electric path. Therefore, measurements were carried out from a distance to avoid this effect. In addition, the measured values differ depending on the location of the power line that penetrates the ZCT of the clamp meter, thus measurements were performed at a location where this effect was minimized. The fraction of compliant branch circuits, whose leakage current was lower than 1.00 mA, was found to be 69.0% out of the total of 439 branch circuits, while the percentage of compliant branch circuits having an insulation resistance higher than $0.20M{\Omega}$ was found to be 93.2%. The reason why the percentage of compliant branch circuits with low leakage current was low might be due to the inclusion of capacitive leakage current in the total measured leakage current.

배터리 수명을 고려한 원격검침 모듈 설계 (Design of a Remote Meter Reading module considering battery life time)

  • 정원창;구명모;장성주;김상복
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권4호
    • /
    • pp.45-50
    • /
    • 2008
  • 계량기의 지침을 인식하고 수도 관리 사업소로 데이터를 전송하기 위한 검침모듈은 전원을 전력선으로 이용할 수 없다. 따라서, 검침모듈은 배터리를 이용해야 하므로 주기적으로 소모된 배터리를 교체하는 유지보수 문제가 발생한다. 유지보수 비용을 절감하기 위해 전원 소모를 줄이면서 무선으로 데이터를 전송 할 수 있는 방안이 필요하다. 본 논문에서는 효율적인 전원관리를 통하여 배터리 소모량을 줄이면서 고객계량기의 지침을 자동으로 인식하고, RF를 이용하여 검침 데이터를 전송 할 수 있는 원격검침 모듈을 설계하였다.

  • PDF

배전원격관리를 위한 차세대 디지털 적산전력계 설계 (A Study on the Design of Advanced Digital Kwh-Meter for the Remote Management of Distribution System)

  • 고윤석;임철수;김관호;윤상문;서성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.238-240
    • /
    • 2002
  • This paper proposes an advanced digital kwh-meter, which records voltage management data, load management data as well as the existing kwh data. This meter supports the requests from DRMS (Distribution Remote Management System) which include kwh meter reading, voltage management data reading, and load management data reading request, it can enhance greatly the economics of the existing remote meter reading system. Also it can improve highly the quality of power supplied to the electric customer by minimizing the voltage management cost and by enhancing the efficiency of load management.

  • PDF

스마트미터를 활용한 건축물의 전력에너지 절감 및 효율화 방안 (Electric Power Energy Saving and Efficient Measures in Buildings using the Smart-Meter)

  • 황현배;정병수
    • 디지털융복합연구
    • /
    • 제12권11호
    • /
    • pp.365-372
    • /
    • 2014
  • 본 논문에서는 스마트미터를 활용한 건축물의 전력에너지 절감 및 효율화 방안에 대하여 실험하였다. 전력에너지 절감을 위해 개선된 자동역률제어시스템(APFC)을 제안하고, 수요전력의 억제(Demand Control) 방안을 제시하였다. 이는 스마트미터의 ICT 기술을 통하여 실시간 양방향으로 콘덴서 뱅킹과 차단기를 직접 제어함으로써 이루어진다. 개선된 APFC는 콘덴서 뱅킹을 보다 다양화하기 위해 이종 용량의 콘덴서를 직병렬 혼합 결선하여 구성함으로써 구축 비용을 최소화 한다. 상기 기능을 위해 Atmel사의 AVR465를 이용하여 PLC 및 Zigbee 통신기능을 갖는 스마트미터를 설계하였다. 24시간 운영되는 숙박시설에 대하여 테스트한 결과 역률은 95%이상을 유지하였고, 과보상은 발생하지 않았음을 확인할 수 있었다.

활선염해 측정장치 개발연구 (II) (A Study on the Laser Salt-meter (II))

  • 김희제;진윤식;이홍식;윤진열;주병수;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1347-1349
    • /
    • 1995
  • Insulators contaminated by salt particles may cause flashovers in humid climate or light rain. Therefore, the quantity of salt on insulators should be monitored not to exceed a critical value. We propose a new remote sensing technique to measure the quantity of salt on insulators of power systems. The amount of the salt is measured from the intensity of the spontaneous emission from the sodium atoms. In this paper, a compact remote on-line salt-meter composed of Q Switch pulsed Nd:YAG laser and emission signal detection system will be introduced. And as the first result of this study, the operating characteristics of our developing laser system is also introduced.

  • PDF