• 제목/요약/키워드: electric meter

검색결과 205건 처리시간 0.028초

지구통계학을 활용한 지반정보 가시화 기법 개발 (The Development of Technique for the Visualization of Geological Information Using Geostatistics)

  • 송명규;김진하;황제돈;김승렬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.501-508
    • /
    • 2001
  • A graph or topographic map can often convey larger amounts of information in a shorter time than ordinary text-based methods. To visualize information precisely it is necessary to collect all the geological information at design stage, but actually it is almost impossible to bore or explore the entire area to gather the required data. So, tunnel engineers have to rely on the judgement of expert from the limited number of the results of exploration and experiment. In this study, several programs are developed to handle the results of geological investigation with various data processing techniques. The results of the typical case study are also presented. For the electric survey, eleven points are chosen at the valley to measure the resistivity using Schlumberger array. The measured data are interpolated in 3-dimensional space by kriging and the distribution of resistivity are visualized to find weak or fractured zone. The correlation length appears to be around 5 to 20 meter in depth. Regression analyses were performed to find a correlation length. No nugget effect is assumed, and the topographic map, geologic formation, fault zone, joint geometry and the distribution of resistivity are successfully visualized by using the proposed technique.

  • PDF

전류 벡터 포텐셜을 이용한 와류분포의 유한요소 해석에 관한 연구 (A Study on the finite Element Analysis of Eddy Current Distributions using Current Vector Potential)

  • 임달호;김민수;신흥교
    • 대한전기학회논문지
    • /
    • 제37권12호
    • /
    • pp.839-846
    • /
    • 1988
  • 전기기기의 와류분포를 해석하고자 항때 자기벡터포텐셜을 이용한 2차원적 해석법을 적용하면 해석영성내의 와류의 크기는 구할수 있지만 그 분포 양상은 알 수 없다. 이러한 문제점을 해결하기 위해 전류 벡터포텐셜을 도입하여 지배방정식을 유도하였으며 이에 유한요소법을 적용하여 2차원적 와류분포해석을 시도하였다. 그리도 시간술분항의 취급에는 시간영성가중계산법을 적용하였으며 이에 따른 알고리즘을 도출하였다. 또한 위에 방법을 해석해가 좌우하는 모델 및 와류에 의해 구동토오크가 발생하는 군상적산전력계 의 알루미늄 원판에 적용하여 해석한 결과 그 타당성 및 유용성을 입증할 수 있었다.

전자 근관장측정기 사용에 있어서 근관세척제의 사용이 측정에 미치는 영향에 관한 연구 (THE EFFECT OF THE CANAL IRRIGANTS ON THE ELECTRONIC WORKING LENGTH DEVICE)

  • 이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.127-133
    • /
    • 1990
  • Electronic working length determination is based on the electrical impedence between the root canal and the periodontal ligament Different canal irrigants with different electric conductivity may effect on the accuracy of the electronic mechanism. 0.9% Saline, 2.5% NaOCl and 3% $H_2O_2$ were evaluated either in wet or in dry condition. The results were as follows. 1. The electrical resistance mearured by Impedence Meter (Model #253, portland, USA) were 1 $K{\Omega}$ in 0.9% Saline, 0.1$K{\Omega}$ in 2.5% NaOCl and 48 $K{\Omega}$ in 3% $H_2O_2$. 2. Saline measured -0.57mm from the actual canal length and had significant difference. When dried with paper points, however, it measured -0.25mm demonstrating no statistical difference. 3. 2.5% NaOCl measured -4.07mm in wet and -2.26mm in dry condition and both showed significant difference from the actual canal length. 4. 3% $H_2O_2$ measured +0.02mm in wet and -0.09mm in dry canals and both appeared to be within acceptable range for the electronic working length mechanism.

  • PDF

Determination of Li by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.;Chung, Bag S.
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.427-434
    • /
    • 1995
  • Inductively coupled plasma mass spectrometry combined with the isotope dilution method is used for the determination of lithium. The isotope dilution method is based on the addition of a known amount of enriched isotope (spike) to a sample. The analyte concentration is obtained by measuring the altered isotope ratio. The spike solution is calibrated through so called reverse isotope dilution with a primary standard. The spike calibration is an important step to minimize error in the determined concentration. It has been found essential to add spike to a sample and the primary standard so that the two isotope ratios should be as dose as possible. Since lithium is neither corrosive nor toxic, lithium is used as a chemical tracer in the nuclear power plants to measure feedwater flow rate. 99.9% $^7Li$ was injected into a feedwater line of an experimental system and sample were taken downstream to be spiked with 95% $^6Li$ for the isotope dilution measurements. Effects of uncertainties in the spike enrichment and isotope ratio measurement error at various spike-to-sample ratios are presented together with the flow rate measurement results in comparison with a vortex flow meter.

  • PDF

Single-Phase Energy Metering Chip with Built-in Calibration Function

  • Lee, Youn-Sung;Seo, Jeongwook;Wee, Jungwook;Kang, Mingoo;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.3103-3120
    • /
    • 2015
  • This paper presents a single-phase energy metering chip with built-in calibration function to measure electric power quantities. The entire chip consists of an analog front end, a filter block, a computation engine, a calibration engine, and an external interface block. The key design issues are how to reduce the implementation costs of the computation engine from repeatedly used arithmetic operations and how to simplify calibration procedure and reduce calibration time. The proposed energy metering chip simplifies the computation engine using time-division multiplexed arithmetic units. It also provides a simple and fast calibration scheme by using integrated digital calibration functionality. The chip is fabricated with 0.18-μm six-layer metal CMOS process and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4096 kHz and consumes 9.84 mW in 3.3 V supply.

충격보강제가 보강된 PPS (polyphenylene sulfide)/MWCNT (multi-walled carbon nanotube) 나노복합체의 물성연구 (Properties of impact modifier reinforced PPS/MWCNT Nanocomposite)

  • 박지수;김승범;남병욱
    • 반도체디스플레이기술학회지
    • /
    • 제11권2호
    • /
    • pp.75-80
    • /
    • 2012
  • Polymer composites which have electrical properties have been studied in various industries. The Multi-walled carbon nanotube (MWCNT) are thought to be reinforcements for polymers because of their high aspect ratio and specially mechanical, thermal and electrical properties. We introduced MWCNT and impact modifier in order to improve thermal and mechanical properties of Polyphenylene sulfide (PPS) and give electric characteristic to PPS. The thermal properties were investigated by Differential scanning calorimeter (DSC) and Thermogravimetric analysis (TGA). The morphology, mechanical properties and electrical characteristic were performed by Field emission scanning electron microscopy (FE-SEM), Izod impact tester and surface resistance meter. As a result, we could find that the PPS/MWCNT composites have high conductivity and good mechanical properties than neat PPS resin.

EEA/탄소나노튜브와 카본블랙 복합체의 PTC/NTC특성 (PTC/NTC Properties of EEA/Carbon nanotube and Carbon Black Composites)

  • 양종석;이경용;최성헌;이재형;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.236-237
    • /
    • 2006
  • We have investigated volume resistivity showed by changing the content of Carbon nanotube and carbon black which is the component parts of semiconducting shield in underground power transmission cable. Specimens were made of sheet form with the six of specimens for measurement. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the preheated oven of both $23{\pm}1[^{\circ}C]$ and $90{\pm}1[^{\circ}C]$. The volume resistivity decreased by adding Carbon nanotube and carbon black. Also the volume resistivity had different properties because of PTC/NTC tendencies at between $23[^{\circ}C]$ and $90[^{\circ}C]$. We experimented with electric properties of semiconducting components with fewer Carbon nanotube than carbon black.

  • PDF

Conductivity Measurements of Submarine Sediments

  • Park, Chan-Hong;Lee, Seung-Hee;Shon, Ho-Woong
    • Journal of the korean society of oceanography
    • /
    • 제36권1호
    • /
    • pp.1-8
    • /
    • 2001
  • An in-situ four-electrode contact resistivity probe system was designed, and field-tested in submarine sediments. Seismic survey was also performed to support and compare the results of electric survey. The probe was designed to be driven to selected depths below the seafloor using a Vibracore system. The four insulated electrodes were, spaced equidistant across the wedge, were extended beyond the probe tip to minimize effects of sediment disturbance by the wedge insertion. In-situ measurements of resistivity were recorded on board by precision electronic equipment consisting of signal generators and processors, and by temperature-monitoring systems. Overall limits of Uncertainty at respective depths below the seafloor are up to ${\pm}$10 of the measured values. Best estimates of conductivity are considered to be ${\pm}$3 percent of the reported values. Resistivity measurements were made at six sites in carbonate sediments to a maximum depth of penetration of about 5 m. Average values of conductivity range between 0.88 and 1.21 mho/m. The results show the seabed is composed of alternating layers of relatively high-conductivity material (0.8 to 1.4 mho/m) in thicknesses of more or less one meter and layers about 30 cm thick having relatively low conductivities (0.4 to 0.8 mho/m).

  • PDF

Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

  • Tourab, Wafa;Babouri, Abdesselam
    • Safety and Health at Work
    • /
    • 제7권2호
    • /
    • pp.102-110
    • /
    • 2016
  • Background: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. Results: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

소규모 재생발전사업자의 중개시장참여 촉진요인 분석 (Analysis of Factors Driving the Participation of Small Scale Renewable Power Providers in the Power Brokerage Market)

  • 이드미트리;배정환
    • 신재생에너지
    • /
    • 제18권3호
    • /
    • pp.32-42
    • /
    • 2022
  • Rapid spread of intermittent renewable energy has amplified the instability and uncertainty of power systems. The Korea Power Exchange (KPX) promoted efficient management by opening the power brokerage market in 2019. By combining small-scale intermittent renewable energy with a flexible facility through the power brokerage market, the KPX aims to develop a virtual power plant system that will allow the conversion of existing intermittent renewable energy into collective power plants. However, the participation rate of renewable power owners in the power brokerage market is relatively low because other markets such as the small solar power contract market or the Korea Electric Power Corporation power purchase agreement are more profitable. In this study, we used a choice experiment to determine the attributes affecting the participation rate in the power brokerage market for 113 renewable power owners and estimate the value of the power brokerage market. According to the estimation results, a low smart meter installation cost, low profit variations, long contract periods, and few clearances increased the probability of participation. Moreover, the average value of the power brokerage market was estimated to be 2.63 million KRW per power owner.