• Title/Summary/Keyword: electric meter

Search Result 205, Processing Time 0.032 seconds

A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV (평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구)

  • Jung Wan-Bo;Park Young-Seuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

CLUSTER ANALYSIS FOR REGION ELECTRIC LOAD FORECASTING SYSTEM

  • Park, Hong-Kyu;Kim, Young-Il;Park, Jin-Hyoung;Ryu, Keun-Ho
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.591-593
    • /
    • 2007
  • This paper is to cluster the AMR (Automatic Meter Reading) data. The load survey system has been applied to record the power consumption of sampling the contract assortment in KEPRI AMR. The effect of the contract assortment change to the customer power consumption is determined by executing the clustering on the load survey results. We can supply the power to customer according to usage to the analysis cluster. The Korea a class of the electricity supply type is less than other country. Because of the Korea electricity markets exists one electricity provider. Need to further divide of electricity supply type for more efficient supply. We are found pattern that is different from supplied type to customer. Out experiment use the Clementine which data mining tools.

  • PDF

On-Line and Off-Line Partial Discharge Properties in the Pumped Storage Generator Stator Windings (양수발전기 고정자 권선에서 운전중 및 정지중 부분방전 특성)

  • Kim, Hee-Dong;Ju, Young-Ho;Yoon, Dea-Hen
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2089-2092
    • /
    • 1999
  • Partial discharge(PD) tests were performed both when the pumped storage generator(rated 13.8kV and 220MVA) was on-line and off-line. This generator has been equipped with 12 bus coupler sensors in directional mode. PD tests were conducted using partial discharge analyzer(PDA), partial discharge meter(PDM) and digital partial discharge detector. PDA showed that the patterns of the normalized quantity number(NQN) and the partial discharge magnitude are in accord with on-line and off-line. The insulation condition was estimated by diagnostic tests(off-line) such as PD magnitude and dissipation factor.

  • PDF

The Study on the Manufacturing of CM-Magnetite Conducting Rubber (CM-Magnetite계(系) 도전성(導電性)고무의 제조연구(製造硏究))

  • Park, Keun-Sik;Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.29 no.2
    • /
    • pp.113-120
    • /
    • 1994
  • The vulcanization characteristics, physical and electrical properties have been measured for magnetite-loaded CM compounds containing various concentration of magnetite. Samples of the various concentration of magnetite are characterized by oscillating disk rheometer, mooney viscometer, tensometer and resistance meter. The morphology and dispersion of magnetite are analyzed by scanning electron microscope(SEM). The results obtained are as follows : 1. The CM compound without magnetite shows plain curve, while the CM compounds containing magnetite show short curves. 2. The maximum volume of magnetite is 600 phr in the CM compounds. The magnetite of 30 to 150 phr of magnetite act as reinforcement agents and the 50 phr magnetite shows maximum tensile strength. 3. The electric conductivity is mostly influenced by the conditions of temperature, compacting pressure, and magnetite orientation. Further efforts should be made to develop a new design in various electric conductivity fillers for the most efficient and applicable rubber products.

  • PDF

A Study on Designing a Real Time Integration Management System of Electric Metering Data (Electric Meter Data의 실시간 통합관리에 대한 연구)

  • KO Jong-Min;Lee Jin-Kee;Kim Sun-Ic;Yu In-Hyeob;Oh Do-Eun;Jang Moon-Jung
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.97-99
    • /
    • 2005
  • 전력산업이 전력회사 중심에서 고객 중심의 비즈니스 서비스로 변함에 따라 고객의 요구 충족을 위한 고기능 전력정보서비스 제공의 필요성이 점차적으로 증대되고 또한 데이터 중심에서 정보, 지식 등 특화된 분석정보 제공은 필수불가결한 요소가 되고 있다. 따라서 효율적 활용과 공용을 전제로 검침데이터에 대한 실시간 처리와 효율적 통합관리기술이 필요하다 하겠다. 본 논문은 전력산업 부가가치를 높일 수 있는 무한한 잠재력을 지닌 전략적 자산으로서 검침데이터에 대한 정확한 처리와 효율적 지원으로 고객서비스의 질을 한 차원 높이는 동기를 마련하는 한편, 검침데이터의 활용과 이용효율성을 극대화하는 방안을 제시하며, 현재 적극적으로 추진되고 있는 전력부가서비스 산업의 활성화에 효과적으로 이용될 것으로 기대한다.

  • PDF

Wireless Power Harvesting Techniques to Improve Time to Fly of Drone (무인항공기 비행시간 향상을 위한 무선 전력획득 기술)

  • Nam, Kyu-hyun;Jung, Won-jae;Jang, Jong-eun;Chae, Hyung-il;Park, Jun-seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1574-1579
    • /
    • 2016
  • This paper presents a self-powered sensor-node scheme using a RF wireless power harvesting techniques for improve drone time of flight. Sensor-node that is proposed is turned when two conditions satisfy: The one is input RF ID data from master-node should be same with sensor-node's ID, and the other one is RF wireless power harvesting system is turned on by hysteresis switch. In this paper, master-node's output is 26 dBm at 263 MHz. Maximum RF to DC power conversion efficiency is about 55% at 4-6 dBm input power condition (2 meter from master-node). The maximum RF wireless power harvesting range is about 13 meter form master-node. And power consumption of the sensor-node's load elements such as transmitter, MCU and temperature sensors is approximately average 15 mA at 5.0 V for 10 msec.

A Real-Time Demand Response Management Using Smart Box (스마트 박스를 활용한 실시간 수요관리)

  • Ko, Dong-Kwan;Bea, Jun-Cheol;Min, Kyoung-Chon;Lee, Jae-Kyu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.57-62
    • /
    • 2016
  • The Demand Response Market is a nation-wide power and energy management program of electric power demand response operated by KPX (Korea Power eXchange). Therefore, any savings could be determined by KEPCO's AMR(Automatic Meter Reading) data. However, the customers and the service providers participating in the market could not know the real time value due to the 15 minute or even more delayed AMR data communicated. Here, a new concept of a smart box has been introduced and demonstrated to provide the real time saving values compared to the current KEPCO's AMR data approach.

An Efficient AMI Simulator Design adapted in Smart Grid (스마트그리드에서의 효율적인 AMI 구현을 위한 통합 시뮬레이터 설계)

  • Yang, Il-Kwon;Choi, Seung-Hwan;Lee, Sang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1368-1375
    • /
    • 2013
  • The Smart Grid, which can monitor or diagnose the power grid in real time to operate efficiently, has been pushed ahead systematically as one of alternatives to solve these issues by combining the advanced Information Communication Technology and the electrical network. Hence, the electric company which introduces smart grid technology can read remotely the electrical meter readings by means of two-way communication between the meter and the central system. This enabled the customer and the utility to take part in reasonable electrical energy utilization. AMI became one of the core foundations in realizing the Smart Grid. It is hard to test the entire process of AMI system before the full deployment because it covers the broad objects from the customer to the utility operation system and requires mass data handling and management. Therefore, we design an efficient AMI network model and a simulator for performance evaluation required to simulate the network model similar to the real environment. This tool supports to evaluate the efficiency of the AMI network equipments and deployment. Additionally, it estimates the appropriate number of deployments and the proper capabilities.

USING REMOTE SENSING TO DETECT THE COASTLINE CHANGE FOR MANGROVE REPLANTATION AT BAN LAEM SING, CHAO PHRAYA RIVERMOUTH, IN THE GULF OF THAILAND

  • Siripong, Absornsuda
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.535-538
    • /
    • 2006
  • The coastline of the Choa Phraya Rivermouth in the Upper Gulf of Thailand has been changed drastically. The western side especially at Ban Laem Sing was eroded for 400 meter in 26 years or with the rate of 15 meter per year on the average. The Metropolitan Electricity Authority has granted five years research project to us to study the efficiency of the electric pole fence as a mean to reduce the wave force and increase sedimentation rate inside for mangrove replantation. If the method works efficiently, it will be used to reclaim the coastal land loss in other areas in Thailand. The project was done since 2005 after the fence was constructed completely in October 2005. The oceanographic surveys were conducted before and after the construction in northeast monsoon season to study the impact of physical oceanographic forces on the coastline change. The sedimentation rates were measured each month. It is rather low about 2 cm/month. The subsiding rate from the load of deltaic sediment and groundwater withdraw using boring data is about 30 mm/year. The cumulative sinking rate is 55.8 cm from 1978 to 1995. We have tried to design the method of mangrove plantation in this area. The remote sensing data such as LANDSAT and aerial photos from 1987 to 2002 for 15 years were used to compute the rate of coastline change at each 50 m section along the western side of the rivermouth.

  • PDF

The Study to Find Causes for Measuring Differences of Hydrogen Fillings in Hydrogen Refueling Station (수소충전소의 연료 계량 방법에 따른 계량 오차가 발생하는 원인 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;CHUNG, JIN BAE;HONG, SUK JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.32-40
    • /
    • 2018
  • There has been an measuring errors between state of charge (SOC; kg) value and mass flow meter (MFM) value in dispenser for hydrogen refueling station. Finally, we observed average 15.5% weight difference between these two values and the MFM readings show a 15.5% higher readout of the SOC readings. Each car was charged with average 2.66 kg of hydrogen fuel during this period. In the initial charging of the day shows less measuring value than the final charging with the maximum 0.038 kg times number of filling. There is no effects of atmosphere temperature change for the hydrogen filled weight during one full year such as January's cold winters and August's hot summers.