• 제목/요약/키워드: electric machine

검색결과 862건 처리시간 0.03초

STS 316鋼 의 高溫低사이클 疲勞强度 와 破壞擧動 에 미치는 크리이프 - 疲勞 相互作용 의 影響 (Effect of creep-fatigue interaction on high temperature low cycle fatigue strength and fracture behavior of STS 316 stainless steels)

  • 오세욱;이규용;김중완;문무경
    • 대한기계학회논문집
    • /
    • 제9권2호
    • /
    • pp.140-149
    • /
    • 1985
  • 본 연구는 오오스테나이트계 STS 316 스테인레스강에 대하여 온도 550.deg. C의 대 기중에서, 변형율제어에 의한 인장-압축에 크리이프 유지시간을 갖는 고온저사이클 피 로시험을 하여 변형율폭 및 크리이프 유지시간이 피로수명에 미치는 영향과 파단면을 주사형 전자현미경으로 관찰하여 크리이프-피로 상호작용이 피로파단면에 미치는 크리 이프 효과를 실험 고찰하였다.

Zr-2.5Nb 중수로 압력관의 조사후 강도 및 파괴거동 특성 (The Strength and Fracture Behavior characteristics of Irradiated Zr-2.5Nb CANDU Pressure Tube Materials)

  • 안상복;김영석;김정규
    • 대한기계학회논문집A
    • /
    • 제25권3호
    • /
    • pp.510-519
    • /
    • 2001
  • The tensile and fracture toughness tests have been conducted to investigate the degradations of mechanical properties induced mainly by neutron irradiations in Zr-2.5Nb CANDU pressure tube materials operated in Wolsung Unit-1. the tests were performed at room, 150, 200, 250, 300 $\^{C}$ for the irradiated and unirradiated specimens in hot cell. The specimens were directly machined from the tube retaining original curvature using specially designed electric discharge machine(EDM). From the tensile tests of the irradiated specimens, it was found that tensile strength was increased and total elongation was decreased compared to those of the unirradiated ones. The active voltages in the fracture toughness tests for the irradiated showed the discontinuous abrupt increases caused by crack jumping in lower temperature. In the crack resistance curves we found the stable crack growth in the unirradiated, whereas the unstable and three crack growth stages in the irradiated specimens due to the accumulated irradiation defects. The various fracture characteristic values in the irradiated are remarkably lower than those of the unirradiated. Through the fractography, we found in the irradiated that smaller dimple and shorter fissures than the unirradiated, and that the fractured surface had three regions that were flat, transition and slant/shear area. These can explain the difference in the crack growth characteristic values of the irradiated and the unirradiated ones.

지질취약구간 터널통과에 따른 지하수위 변화량 분석 (Analysis of Changes in Groundwater Level according to Tunnel Passage in Geological Vulnerable Zone)

  • 최정열;양규남;김태준;정지승
    • 문화기술의 융합
    • /
    • 제6권3호
    • /
    • pp.369-375
    • /
    • 2020
  • 본 연구의 검토대상 구간은 전력구 시공을 위한 쉴드 TBM 굴착 도중 터널 막장면을 통해 지하수 유출이 발생한 구간이다. 따라서 공사 전부터 지하수위의 변화가 발생되는 시점까지의 상황을 분석하기 위해 공사 중 관찰된 지하수위 변화를 토대로 주변 지반현황을 반영하여 3차원 수치해석을 수행하였다. 이를 통해 현장 주변에서 발생한 지하수위 변화와 터널공사의 상관성을 파악하였다. 본 연구의 수치해석결과는 대상지반에서 측정된 지하수위 계측결과와 유사하며 쉴드 TBM 막장면으로의 지하수 유출량 또한 실제 측정결과와 유사한 수준으로 나타나 본 연구에서 설정한 수치해석 방법과 모델링은 현장여건을 잘 반영하는 것으로 분석되었다.

3D가상 현실방식을 사용한 수술교육시스템의 연구 (Study for Operation Teaching Machine Using 3D Virtual Reality System)

  • 강병훈;김지숙;김한웅
    • 디지털콘텐츠학회 논문지
    • /
    • 제17권4호
    • /
    • pp.287-293
    • /
    • 2016
  • 시간, 공간, 금전적인 문제 때문에 실습이 쉽지 않은 학문들이 있다. 특히 의료교육은 장소와 시간의 제약이 특히 심하며 cadaver(카드버:인체해부 실습용 시체)를 통해 이루어지기 때문에 어려움이 많다. 그 대안으로 다양한 가상 수술방법이 존재하지만 장비가 고가이거나 구하기 쉽지 않기 때문에 어려운 문제가 발생한다. 이러한 문제점의 해결 방법으로 3D-Virtual Reality(3D가상현실)를 활용하여 실제와 유사한 환경을 제공하고자 한다. 일반적으로 컴퓨터의 Interface(인터페이스)로 키보드와 마우스를 사용하지 않고 Oculus Rift(오큘러스 리프트)와 Leap Motion(립 모션)를 사용함으로써 더욱더 현실감을 느낄 수 있어 실습교육비용을 절감함으로써 실습교육에 대한 효과를 극대화 할 수 있다. 본 논문에서는 두개의 Device(디바이스)인 Oculus Rift(오큘러스 리프트)와 Leap Motion(립 모션)를 이용하여 3D가상 수술 시스템을 구축하고 실습할 수 있는 제안으로 의료교육인 수술교육에 대치하여 효율성을 높이는 방식을 제안하였고, 이는, 다른 Simulation(시뮬레이션)이 활용 가능한 학문분야에 까지 확장할 수 있을 것으로 사려된다.

치관 보철물 제작에 사용되는 치과용 금속의 변연 적합도 비교 (A comparison of marginal fitness by dental alloys)

  • 김남중;황경숙;박용덕
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.29-40
    • /
    • 2003
  • This study was aimed to verify a comparison by dental alloys upon the marginal fitness of dental prosthesis. Firstly, we waxed up on 45 epoxy resin dies, pressed the margin with hands, and identified the marginal fitness with microscope. And we made a single direct spruing system type of sprue by 3 dental alloys - metal crown alloys, PFM crown alloys, and gold crown alloys - each 15, total 45 waxing up, adjusting W/P ratio and invested the cast ring. Then, we made the dental prosthesis using the electric casting machine. In these processes we followed the manufacturer's instructions, in order to maintain the other conditions from the inner and outer, which included investment and burning out. After we tried on the dental prosthesis on epoxy resin dies, we have got the means of marginal gap at 9 points with same distances, around the cervical line which was checked already, using microscope($\times$300). The results of this study were as follows : 1. Metal crown alloys showed 2.9% better in marginal fitness than PFM crown alloys, and the difference was not statistically significant(P=0.497). 2. Gold crown alloys showed 31.3% better in marginal fitness than Metal crown alloys, and the difference was statistically significant(P=0.004). 3. Gold crown alloys showed 32.4% better in marginal fitness than PFM crown alloys, and the difference was statistically significant(P=0.002). 4. We saw that Gold crown alloys was the best dental alloys in the marginal fitness among the three.(P=0.049).

  • PDF

경암의 취성도와 TBM 순굴진율간의 관계 (Relationship between brittleness index of hard rocks and TBM penetration rates)

  • 이기준;권태혁;김경열;송기일
    • 한국터널지하공간학회 논문집
    • /
    • 제19권4호
    • /
    • pp.611-634
    • /
    • 2017
  • 도시의 발전에 따라 전력선, 통신선, 상하수도배관 등을 공동으로 수용하는 공동구의 수요는 점점 증가할 것으로 예상되고 있으며 따라서 앞으로 TBM을 이용한 터널시공이 증가할 것으로 예상된다. TBM을 이용한 터널 건설시 굴진율 예측은 공기와 공사비 책정의 중요한 요소이다. 현재, NTNU model, CSM model 등의 TBM 굴진율 예측방법이 있지만, 이 방법들은 많은 입력 인자들을 필요로 한다. 본 논문은 문헌조사를 통해 다양한 여러 지반 물성인자들 중, 경암의 취성지수 (Brittleness index)와 TBM 순굴진율간의 관계를 도출하고자 하였다. 특히, 인장강도와 압축강도의 함수인 취성지수는 그 정의에 따라 순굴진율과 관계가 다르고 매우 큰 분산을 가지는 것으로 나타났다. 본 연구는 TBM 순굴진율 예측에서 암반물성 중 취성도가 지니는 의미를 제시하고 있다.

Glass Fiber Post와 Composite Resin Core의 전단결합강도 (A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST)

  • 김태형;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

마찰식 박피마늘 선별기 개발 (Development of A Friction Type Garlic Separator)

  • 박재복;김종태
    • Journal of Biosystems Engineering
    • /
    • 제19권3호
    • /
    • pp.185-193
    • /
    • 1994
  • Both the wet and dry types of garlic peeling machines are being presently used in domestic garlic processing factory, but the dry type is more popular than the wet type because of higher peeling efficiency. The peeling efficiency of these machines is estimated 50 to 80%, depending on the difference in garlic varieties, physical properties and moisture content of garlic samples. If the peeling time is increased in order to improve the peeling efficiency, the damage on the surface of peeled garlic and the consumption of electric power are also increased. This study was carried out to solve these problems in garlic peeling operation and to obtain the optimun design factor for the friction type separator. The results are summarized as follows : 1. The average friction coefficients of peeled and unpeeled garlic samples were 0.91 and 0.51. respectively, for the acrylic plate, and 0.96 and 0.51, respectively, for the stainless plate. 2. For the inclined acrylic pipe with the pipe length 90 cm, the inclined angle $39^{\circ}$ and the pipe diameter 45-55 mm, the falling time of peeled garlic samples was 0.2 sec, faster than unpeeled garlic samples. 3. For the inclined stainless pipe with the pipe length 90 cm, the inclined angle $34^{\circ}$, $39^{\circ}$ and the pipe diameter pipe 35 mm, the falling time of peeled garlic samples was 0.7 sec, slower than that with the pipe diameter 47mm. 4. The stainless pipe with the pipe length 80~90 cm, the inclined angle $39^{\circ}{\sim}40^{\circ}$ and the pipe diameter 40~50 mm was the most suitable as the material of friction pipe. 5. Experimental garlic peeling machine is composed of garlic sample feeding device, friction stainless pipe and hopper. The peeling efficiency was 81 to 96%, and the separating capacity, 600 gr/min.

  • PDF

섬유화 온도 변화에 따른 E-glass fiber의 물리적 특성 (Physical Properties of E-glass Fiber According to Fiberizing Temperature)

  • 이지선;이미재;임태영;이영진;전대우;현승균;김진호
    • 한국재료학회지
    • /
    • 제27권1호
    • /
    • pp.43-47
    • /
    • 2017
  • E (Electric) -glass fibers are the most widely used glass fibers, taking up 90 % of the long glass fiber market. However, very few papers have appeared on the physical characteristics of E-glass fibers and how they depend on the fiberizing temperature of fiber spinning. Glass fiber was fabricated via continuous spinning process using bulk E-glass. In order to fabricate the E-glass specimen, raw materials were put into a Pt crucible and melted at $1550^{\circ}C$ for 2hrs; mixture was then annealed at $621{\pm}10^{\circ}C$ for 2hrs. The transmittance and adaptable temperature for spinning of the bulk marble glass were characterized using a UV-visible spectrometer and a viscometer. Continuous spinning was carried out using direct melting spinning equipment as a function of the fiberizing temperature in the range of $1175{\sim}1250^{\circ}C$, while the winder speed was fixed at 500 rpm. Subsequently we investigated the physical properties of the E-glass fiber. The average diameter of the synthesized glass fiber was measured by optical microscope. The mechanical properties of the fiber were confirmed using a UTM (universal materials testing machine); the maximum tensile strength was measured and found to be $1843{\pm}449MPa$ at $1225^{\circ}C$.

간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review (Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF