• Title/Summary/Keyword: electric insulation layer

Search Result 38, Processing Time 0.029 seconds

Analysis of Electric Field Distribution and Characteristics of Volume Resistivity in HDPE/EVA Film for Recycling (재활용을 고려한 HDPE/EVA필름의 전계분포 및 체적저항특성 해석)

  • Lee, Hung-Kyu;Lim, Kee-Joe;Kim, Yong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.801-807
    • /
    • 2008
  • Recently, CV, CN-CV and CNCV-W cable are used for HVDC transmission and distribution cable. However, XLPE which is used as insulation layer of power cable has thermosetting properties. It is very difficult to recycling. In this paper, we prepared HDPE/EVA film, which the blending ratio are 80:20, 70:30, 60:40, 50;50 respectively for the purpose of recycling. Main factor such as electric field distribution and its resistivity in insulation system affected on insulation performance and reliability for HVDC applications. Therefore, electric field distribution formed by space charge and characteristics of volume resistivity was currently investigated. We suggest the possibility of utilization for HVDC insulation layer from the results.

Insulation Design and Testing of HTS coil for 6.6 kV Class HTSFCL (6.6kV급 고온초전도 한류기용 HTS 코일의 절연 설계 및 시험)

  • 백승명;정종만;곽동순;류엔반둥;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.263-268
    • /
    • 2003
  • The Electrical insulation design and testing of high temperature superconducting (HTS) coil for high temperature superconducting fault current limiter (HTSFCL) has been performed. Electrical insulating factors of HTS coil for HTSFCL are turn-to-turn, layer-to-layer. The electrical insulation of turn-to-turn depends on surface length, and the electrical insulation of layer-to-layer depends on surface length and breakdown strength of L$N_2$. Therefore, two basic characteristics of breakdown and flashover voltage were experimentally investigated to design electrical insulation for 6.6㎸ Class HTSFCL. We used Weibull distribution to set electric field strength for insulation design. And mini-model HTS coil for HTSFCL was designed by using Weibull distribution and was manufactured to investigate breakdown characteristics. The mini-model HTS coil had passed in AC and Impulse withstand test.

  • PDF

The Investigation on Thermal Aging Characteristics of Oil-Paper Insulation in Bushing

  • Liao, Rui-jin;Hu, En-de;Yang, Li-jun;Xu, Zuo-ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1114-1123
    • /
    • 2015
  • Bushing is the key link to connect outer and inner insulating systems and also the essential electric accessory in electric power system, especially in the high voltage engineering (AC 1000kV, DC 800kV). This paper presented the experimental research of thermal aging characteristic of oil-paper insulation used in bushing. A thermally accelerated aging experiment at 90℃ was performed. The bushing models containing five layers of paper were sealed into the aging vessels and further aged for 250 days. Then several important parameters associated with the aging were observed and evaluated. The results showed that the degree of polymerization (DP) of papers gradually decreased. The DP values of outermost layer and middle layer fit well into the second-order kinematic model and first-order kinematic model, respectively. Less deterioration speed of the inter-layer paper than outer layer was confirmed by the variation of DP. Hydrolysis was considered as the main cause to this phenomenon. In addition, the logarithm of the furfural concentrations in insulation oil was found to have good linear relationship with DP of papers. Interestingly, when the aging time is about 250 days and DP is 419, the aging process reaches an inflection point at which the DP approaches the leveling off degree of polymerization (LODP) value. Both tanδ and acid number of oils increased, while surface and volume resistivity of papers decreased. The obtained results demonstrated that thermal aging and moisture absorbed in papers brought great influence to the degradation of insulating paper, leading to rapid decrease of DP and increase of the tanδ. Thus, the bushing should be avoided from damp and real-time monitoring to the variation of tanδ and DP values of paper is an effective way to evaluate the insulation status of bushing.

Study on Insulation Design of Surge Voltages for Convex Winding type Ribbon Core Transformer (Convex형 권선배치방식을 취한 권철심변압기의 충격파절연설계에 관한 연구)

  • 황영문;조철제;김중한
    • 전기의세계
    • /
    • v.22 no.3
    • /
    • pp.13-24
    • /
    • 1973
  • In this report, as a method to solve the problems on impulse insulation coordination in ribbon core transformer owing to it's BIL stepping up, new design to alter winding distribution of multiple-layer concentric winding to Convex type winding is proposed. The main focus of this method is to settle the weakness of axial direction insulation strength and as a result of theoretical analysis through experiment of model transformers, the following conclusions are obtained; (a) As the electric loadings in a design which increases by strengthenning axial direction insulation endurance in presently avarilable transformers owing to it's BIL stepping up can be restricted in Convex type winding, reasonable design will be suited to the transformer with higher BIL. (b) Convex type winding is a very improved insulation design in respect of insulation coordination because it has shield plate effect to even impulse oscillation. (c) There is a disadvantage to cause leakage flux to increase in Convex type winding, however, the constancy of electric loadings in a design in spite of BIL stepping up restricts the increase of leakage flux to some extent.

  • PDF

Characteristics of 345KV O.F Cable employing PPLP(Polypropylene Laminated Paper) (PPLP 를 이용한 34SKV O.F Cable 의 제특성)

  • Park, J.G.;Kim, J.W.;Lee, E.J.;Kang, S.H.;Yu, I.K.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.415-417
    • /
    • 1989
  • In this paper we introduce electrical and mechanical properties of PPLP, an insulation system of Cellulose/Extruded Polypropylene/Cellulose Paper, and characteristics of 345KV O.F cable employing the PPLP. This cable shows dielectric loss less than 50% and has excellent impulse breakdown strength higher than 17%, respectively, compared with those of the conventional cables. Accordingly, a more compact cable with reduced thickness of the insulation layer, which has remarkable profits in economics, has been developed.

  • PDF

AC Breakdown Strength According to Crystallinity and Diffusion of Crosslink By-products by Annealing of XLPE (XLPE의 열처리에 의한 결정화도, 가교부산물의 확산에 따른 교류파괴전압 특성)

  • Kim, Young-Ho;Lee, Sang-Jin;Lee, Seung-Yop;Choi, Myung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1608-1610
    • /
    • 2000
  • In this work, the effect of annealing on physical and electrical properties of XLPE cable insulation was investigated. One sample was non-annealed and the other two samples were treated under air circulated oven at 80$^{\circ}C$ for five and ten days. In the DSC patterns of annealed specimen, new peaks appeared at near 80$^{\circ}C$ as a proof of thermal history. The degree of crystallinity increased by annealing effect. In the FT-IR spectrums, the change of absorbances to acetophenone and cumyl alcohol were observated according to the radial direction of cable insulation. They slowly diffused into both semi-conductive layer of the cable in proportion to annealing time and lastly led to near equilibrium state through cable insulation. The AC breakdown strength did not increased but the values were stabilized by effects of crystallinity and diffusion of by-products.

  • PDF

Study on Vibration Energy Harvesting with Small Coil for Embedded Avian Multimedia Application

  • Nakada, Kaoru;Nakajima, Isao;Hata, Jun-ichi;Ta, Masuhisa
    • Journal of Multimedia Information System
    • /
    • v.5 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • We have developed an electromagnetic generator to bury in subcutaneous area or abdominal cavity of the birds. As we can't use a solar battery, it is extremely difficult to supply a power for subcutaneous implantation such as biosensors under the skin due to the darkness environment. We are aiming to test the antigen-antibody reaction to confirm an avian influenza. One solution is a very small generator with the electromagnetic induction coil. We attached the developed coil to chickens and pheasants and recorded the electric potential generated as the chicken walked and the pheasant flew. The electric potential generated with physical simulator is equal to or exceeds the 7 V peak-to-peak at maximum by 560/min of flapping of wings. Even if we account for the junction voltage of the diode (200 mV), efficient charging of the double-layer capacitor is possible with the voltage doubler rectifier. If we increase the voltage, other problems arise, including the high-voltage insulation of the double-layer capacitor. For this reason, we believe the power generated to be sufficient for subcutaneous area of birds. The efficiency, magnetic 2 mm in length and coil 15mm in length, if axial direction is rectified, the magnetic flux density given to the coil could calculated to 7.1 % and generated power average 0.47mW. The improvements in size and wire insulation are expected in the future.

Breakdown, V-t and Degradation Characteristics of Insulation in Liquid Nitrogen for HTS Transformer (고온초전도 변압기를 위한 액체질소 중 절연 파괴, V-t. 열화 특성)

  • Nguyen, Van-Dung;Joung, Jong-Man;Baek, Seung-Myeong;Lee, Chang-Hwa;Suck, Song-Hee;Kim, Sang-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.316-323
    • /
    • 2004
  • HTS transformer is one of the most promising devices to supply enough electric energy for quick increase consumption. However, for practical design of the HTS transformer, it is necessary to establish the research on breakdown, V-t characteristics, degradation, and so on. In this paper, we discussed breakdown characteristics and V-t characteristics of polyimide/L$N_2$ and glass fiber reinforced plastic/$LN_2$ composite insulations. These composite insulations have been used as turn-to-turn and layer-to-layer insulations for HTS transformer respectively, Moreover, we investigated the degradation of these insulation samples after breakdown using microscope and SEM photograph.

Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables (고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2017
  • The demand for electric power is increasing every year. All facilities operating at power stations and all facilities used in transmitting high volumes of electric power are therefore expected to operate with a high degree of reliability. 6.6 kV XLPE 100 SQ 1C cables are used to deliver high levels of generated electric power. Depending on the method of manufacture, installation environment, and usage conditions, the deterioration processes of power cables start from the instant of operation. Cable junctions may break down in three years from the start of operation due to manufacturing or construction defects. We have invented the first device in Korea to monitor the status of live cables and installed these at Korea Western Power Co., Ltd.. We have set the criteria to determine deterioration status and specified the degree of deterioration at which one should replace the cables. In this paper, we present the effect of insulation layer and sheath on the insulation resistance status in cables.