• 제목/요약/키워드: electric field measurement

검색결과 453건 처리시간 0.023초

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.

뇌방전의 리더진전에 따른 전장파형의 측정과 분석 (Measurement and Analysis for Electric Fields due to Lightning stepped leaders)

  • 이복희;정광희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2164-2166
    • /
    • 1999
  • This paper is describes the measured electric field waveform radiated by lightning discharge. We have performed measurement and analysis of the electric fields associated with stepped leaders. Electric field measurement system was composed of hemisphere electric field sensor, measurement system of a distance from lightning strokes, automatical recording system, A/D board, personal computer etc. A/D board have high sampling time, high speed data processing, 8bit of resolution. Also, measured characteristics of stepped leaders radiated by were analyzed.

  • PDF

비양기구로 운반되는 전계센서를 이용한 대기전계의 측정과 분석 (Measurement and Analysis of the Atmospheric Electric Field using Balloon-Carried E-Field Sensor)

  • 김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.78-84
    • /
    • 2016
  • This paper is focused on the measurement and analysis of an atmospheric electric field which is caused by thunderclouds. The electric field due to thunderclouds changes very slowly. For this reason, the extremely low frequency E-field sensor needs to be used for measuring the atmospheric electric field strength. The balloon-carried E-field sensor system with the time constant of 1sec was designed and fabricated. The electric field sensor consists of $100mm{\times}100mm$ copper plate, active integrator, high pass and low pass filters and batteries. The measurements of atmospheric electric fields were made by the balloon-carried E-field sensor and radiosonde, which sends the data back to ground in real time. From the calibration experiments, the response sensitivity of the E-field sensor was 0.154mV/kV/m in the frequency range of less than 1kHz. As a result from the actual experiment of the atmospheric electric field, the electric field signals were observed from the altitude of about 2.5km. Also, as the altitude was increased, the detected electric field wave oscillated with the fluctuation of sensing plate. The proposed method seems suitable for measurements of atmospheric electric fields, because it is inexpensive, simple to use and launch.

The Effect of External DC Electric Field on the Atmospheric Corrosion Behaviour of Zinc under a Thin Electrolyte Layer

  • Liang, Qinqin;YanYang, YanYang;Zhang, Junxi;Yuan, Xujie;Chen, Qimeng
    • Corrosion Science and Technology
    • /
    • 제17권2호
    • /
    • pp.54-59
    • /
    • 2018
  • The effect of external DC electric field on atmospheric corrosion behavior of zinc under a thin electrolyte layer (TEL) was investigated by measuring open circuit potential (OCP), cathodic polarization curve, and electrochemical impedance spectroscopy (EIS). Results of OCP vs. time curves indicated that the application of external DC electric field resulted in a negative shift of OCP of zinc. Results of cathodic polarization curves measurement and EIS measurement showed that the reduction current of oxygen increased while charge transfer resistance ($R_{ct}$) decreased under the external DC electric field. Variation of OCP negative shift, reduction current of oxygen, and $R_{ct}$ increase with increasing of external DC electric field strength as well as the effect of external DC electric field on double-layer structure in the electrode/electrolyte interface and ions distribution in thin electrolyte layer were analyzed. All results showed that the external DC electric field could accelerate the corrosion of zinc under a thin electrolyte layer.

평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발 (Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor)

  • 강전홍;류제천;이상화;김규태;김명수;한상옥;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권9호
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

Compensation of Electric Field Interference for Fiber-optic Voltage Measurement System

  • Cho, Jae-Kyong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권2호
    • /
    • pp.84-88
    • /
    • 2008
  • In this paper, we analyze the errors associated with electric field interference for fiber-optic voltage sensors working in a three-phase electric system. For many practical conductor arrangements, the electric filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of 1 %.

뇌격거리측정계 및 뇌방전에 의해 발생하는 전장의 스펙트럼 분석 (Measurement System of a Distance from Lightning Strokes to Observatory and Spectrum Analysis of Electric Fields Radiated from Lightning Discharges)

  • 이복희;장석훈;정광희;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1656-1658
    • /
    • 1998
  • This paper deals with a measurement system of a distance between lightning strokes and observatory station and spectrum analysis of electric fields radiated from lightning discharges. The distance measurement system, which consists of a loop type magnetic field sensor, a microphone and one chip microprocessor, is connected to a personal computer through RS232 port to acquire and process the data. This system is to use a difference of propagation velocity between an electromagnetic wave and a sonic wave produced by lightning discharge. Also, an electric field waveform and a frequency spectrum were investigated by an electric field measurement system with a hemisphere antenna and a spectrum analyzer with a biconical antenna and a log-periodic antenna, respectively. The results would be used as a basic reference to protect the power systems and electric circuits from lightning overvoltages.

  • PDF

Time Resolved Measurement of Electric Field Distribution in a Liquid Dielectric

  • Arii, Kiyomitsu;Ihori, Haruo;Fujii, Masaharu
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.287-291
    • /
    • 2002
  • Measurement technique of three dimensional electric field distribution in liquid dielectrics have been studied. Kerr effect and computed tomography(CT) method have been used. Measuring time has been shortened by the use of multi-optical systems to less than several milliseconds. Near future, electric field distribution in front of a streamer tip of breakdown would be measured.

유전체 매질내에 있는 구형공동에 의한 근거리 회절패턴 (NEAR=FIELD DIFFRACTION PATTERN BY A SPHERICAL AIR CAVITY IN A DIELECTRIC MEDIUM)

  • 강진섭;라정웅
    • 전자공학회논문지A
    • /
    • 제32A권2호
    • /
    • pp.19-30
    • /
    • 1995
  • Diffraction patterns of the copolarized and the crosspolarized total electric fields by a spherical air cavity in a dielectric medium are analyzed in the forward near-field region when the wavelength of the incident plane wave is comparable to one half of the cavity radius. It is shown that double nulls and dips of the copolarized and the crosspolarized total electric fields exist in the measurement plane tansverse to the propagating direction of the incident field, and their dependences on the frequency, the distance of the measurement plane, and the measurement angle are analyzed.

  • PDF

Pilot 채널을 이용한 WCDMA 기지국의 최대 전기장 강도 예측 (Maximum Electric Field Strength Prediction of WCDMA Base Station Using Pilot Channel)

  • 이영수;윤현구;장병준
    • 한국전자파학회논문지
    • /
    • 제22권10호
    • /
    • pp.1016-1019
    • /
    • 2011
  • 본 논문에서는 코드 영역에서의 pilot 채널의 전기장 강도를 측정하여 WCDMA 기지국에서 방사되는 전기장 강도의 최대값을 예측하였다. 사용된 방법의 타당성을 제시하기 위하여 자체 제작한 시험 기지국에서 광선 추적법을 이용한 이론값과 전체 대역에 대한 전기장 강도 측정 결과와 비교하여 90 % 이상 일치함을 확인하였다. 그리고 실제 운용 중인 기지국을 대상으로 채널 전체에 대한 전기장 강도 측정 결과를 논문에서 제안한 방법으로 예측한 결과와 비교하였다. 비교한 결과, pilot 채널을 이용하면 최대 트래픽 상태의 전기장 강도를 예측할 수 있음을 확인하였다. 본 측정방법은 국내 무선국 전기장 강도 검사에 효과적으로 적용될 수 있다.