• Title/Summary/Keyword: electric currents

Search Result 501, Processing Time 0.024 seconds

The Effect of Electrical Stimulation on Osteoblast Surrounding Dental Implant (치과용 임플란트 주위 뼈모세포에 대한 전기자극의 영향에 관한 연구)

  • Woo, Kyung-Yeup;Kwon, Kung-Rock;Choi, Boo-Byung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.195-206
    • /
    • 2003
  • Several factors can affect the formation of bone tissues surrounding implants. One of the factors is electrical stimulation. It is known to change the movement of cells, form and destroy cells, and alter concentration and chemical component of soft tissues and bones. The effect of electrical stimulation on bone formation can vary according to the intensity of electric currents, stimulating time, the method of sending electric currents, and tissues and cells currents are applied to. This study examines how various enviroments affect osteoblasts. (1) effect on osteoblast with varying intensity of currents Osteoblast-like cells were raised on four plates where implants can be placed. A constant current sink (MC3T3-E1) that can adjust the intensity and stimulating time of electric currents was used. The four plates were stimulated with $0{\mu}A$, $10{\mu}A$, $20{\mu}A$, and $40{\mu}A$, respectively. After 24 hours of stimulation, the number and distribution of cells surrounding implants were examined. (2) effect on osteoblast with varying conditions The 3 study was performed with same method. (1) The change of attached cell number 72-hour after application of various currents (2) The change of attached cell number 72-hour after application of various interval (3) The comparison of attached cell number by implant surface texture The following are the results: 1. The distribution and density of cells surrounding implant is highest under the intensity of electric currents of $20{\mu}A$. 2. The number of cells attached implants is highest under the intensity of electric currents of $20{\mu}A$. 3. The number of cells attached implants is highest under continous electric currents 4. The number of cells attached implants is not different by implant surface texture.

Relationships of Elementary Students념 Conceptions about Basic Circuits and Electric Currents (초등학생의 전기회로 개념과 전류 개념간의 관계)

  • 김진숙;권성기
    • Journal of Korean Elementary Science Education
    • /
    • v.19 no.2
    • /
    • pp.1-13
    • /
    • 2000
  • The purposes of this study were to survey the elementary students' conceptions of electric circuits and of electric currents, and to explore the relationships between them. The questionaire were developed into matched forms which corresponds to each conceptions of electric circuits and electric currents. The elementary students were selected from 4th and 5th grade in a elementary school in a large local city, which of the total numbers of students were 163. The student who have well-developed conception in electric circuits are superior in conceptions of electric currents to other student who have not in each items of questionnaire required to draw a simple basic electric circuits for lightening the bulb, to select the basic elements of circuits, to identify the arrangement of batteries and bulbs. So we concluded that the scientific conceptions of electric circuits could contribute to the scientific conceptions of electric currents, as expected in elementary science textbooks.

  • PDF

Calculation of Electric Potential Rise of Horizontal Grounding Electrode Caused by Lightning Stroke Currents (뇌격전류에 의한 수평접지극의 전위상승 계산)

  • Lee, Bok-Hee;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.81-86
    • /
    • 2013
  • An electric potential rise of the grounding electrode developed by the lightning stroke currents should be calculated for the purpose of effective protection of electrical and electronic equipment. In this paper, the electromagnetic model was applied to calculate the harmonic impedance of grounding electrode. Also the empirical equation related to the permittivity and resistivity of soil was used. The lightning current waveforms, which are expressed by the Heidler's equation, were used in order to calculate accurately transient electric potential rises. The transient voltage was obtained by using the simulated harmonic impedance and the lightning current in frequency domain. Finally, the transient voltages of horizontal grounding electrode(10m) under lightning stroke currents were calculated by IFFT(Inverse Fast Fourier Transform).

A study on an earthing system without ground connection (대지에 매설할 필요가 없는 접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Chang-Bong;Woo, Jea-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.258-261
    • /
    • 2009
  • This paper proposes an earthing system without ground connection. As a Green IT Environmental Solution, Internal-external surge and other unnecessary electric currents are converted into energy and through a discharge the signal is reduced. It's a structure that discharges through a neutral electric transformer. The results show that the electric potential rising of the earthing system proposed in this paper are approximately below the half and the discharge currents increased approximately 9 times when compared to existent earthing systems. This earthing system is economical, easy to install and can solve environmental contamination.

  • PDF

Experimental investigation of electric currents flowing through human body in electirc shock (전기충격시인체에 흐르는 전류의 실험적 고찰)

  • 김완배;안광윤;윤태원
    • 전기의세계
    • /
    • v.29 no.1
    • /
    • pp.21-27
    • /
    • 1980
  • The effect of electric shock on human body is enormousness, which leads to warmth, tingling, and even death. The mean values of perception currents obtained on 91 men and 39 women are about 0.77(mA) for men and 0.57(mA) for women. The mean value for women is approximately seven tenths that of men. An individual can tolerate, with no adverse effects, repeated exposure to the reactions associated with currents of his let-go level, and the mean value of let-go currents obtained from 27 normal men is 6.29(mA). Lethal currents flowing human body is very dangerous even for a short time. So, it is necessary to have recourse to animal experiments ot determine lethal current for human. An analysis of experimental data indicates that body weight and shock duration are important factors in determining the lethal current. It is suggested that the relationship between current and shock duration is given by I=K/.root.T, and lethal current is proportional to body weight, where I is the current in milliampere, and T is the time in seconds.

  • PDF

Fully coupled multi-hull/mooring/riser/hawser time domain simulation of TLP-TAD system with MR damper

  • Muhammad Zaid Zainuddin;Moo-Hyun Kim;Chungkuk Jin;Shankar Bhat
    • Ocean Systems Engineering
    • /
    • v.13 no.4
    • /
    • pp.401-421
    • /
    • 2023
  • Reducing hawser line tensions and dynamic responses to a certain level is of paramount importance as the hawser lines provide important structural linkage between 2 body TLP-TAD system. The objective of this paper is to demonstrate how MR Damper can be utilized to achieve this. Hydrodynamic coefficients and wave forces for two bodies including second-order effects are obtained by 3D diffraction/radiation panel program by potential theory. Then, multi-hull-riser-mooring-hawser fully-coupled time-domain dynamic simulation program is applied to solve the complex two-body system's dynamics with the Magneto-Rheological (MR) Damper modeled on one end of hawser. Since the damping level of MR Damper can be changed by inputting different electric currents, various simulations are conducted for various electric currents. The results show the reductions in maximum hawser tensions with MR Damper even for passive control cases. The results also show that the hawser tensions and MR Damper strokes are affected not only by input electric currents but also by initial mooring design. Further optimization of hawser design with MR Damper can be done by active MR-Damper control with changing electric currents, which is the subject of the next study.

Electric Fire Hazard in Low Voltage Distribution Circuits Protected by Electric Leakage Circuit Breaker(ELB) (누전차단기로 보호되는 저압선로에서의 발화위험성)

  • 홍성호;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.93-99
    • /
    • 2000
  • This paper presents a study on the assessment of electrical fire hazards by electric circuits with leakage. The hazards are evaluated with the energy supplied by earth-leakage currents which flow in the circuits simulating the actual circuit of domestic premises. Also, operating time and current of ELB are measured by an experimental approach. A common specification of ELB used in this paper has a sensitivity of 30[mA] for leakage current working on the current-balance principle. Total charges and energy of leakage currents are calculated quantitatively by a theoretical approach and compared with the results obtained from experiments.

  • PDF

THE EFFECT OF EXOGENOUS ELECTRIC CURRENTS ON CYCLIC NUCLEOTIDES IN FELINE ALVEOLAR BONE (외인성전류가 고양이 치조골의 cyclic nucleotides에 미치는 영향에 관한 연구)

  • Kim, Young-Bok;Lee, Jong-Heun;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.187-202
    • /
    • 1984
  • There are evidences that exogenous electric currents are capable of enhancing bone formation and resolution, and that the conversion of the bioelectric response to biochemical activity provides the directional component of orthodontic tooth movement. In addition, evidence has implicated cyclic nucleotides in alveolar bone cellular activation mechanism during orthodontic tooth movement. In view of these evidences, this study was performed to investigate the effects of exogenous electric currents on cyclic nuclotide levels in feline alveolar bone and the possible clinical application of electric currents as an additional orthodontic tool. In the first study, three groups of three adult cats were subjected to application of a constant direct current of $10{\pm}2$ microamperes to gingival tissue near maxillary canine noninvasively for 1, 3, and 7 days respectively. In the second study, three groups of three adult cats each were treated by an electric-orthodontic procedure for 1, 3, and 7 days respectively. The left maxillary (control) canine received an orthodontic force of 80gm alone at time of initiation, while the right maxillary (experimental) canine received combined force-electric stimulation (80gm of force and $10{\pm}2$ microamperes of a constant D.C. currents). Alveola, bone samples were obtain from the mesial (tension and/or cathode) and the distal (compression and/or anode) sites surrounding maxillary canines as well as from contralateral control sites. The samples were extracted, boiled, homogenized, and the supernatants were assayed for cyclic nucleotides (cAMP, cGMP) by a radioimmunoassay method. And also the amount of tooth movement was measured in the second study. On the basis of this study, the following conclusions can be drawn: 1. The fluctuation pattern of cyclic nucleotide levels in alveolar bone treated by exogenous electric currents was similar to that treated by orthodontic force. 2. The cAMP levels in alveolar bone of electrically treated teeth significantly elevated above the control values. And of electrically treated teeth, the values of the anode sites were higher than those of the cathode sites. 9. The cGMP levels in alveolar bone of electrically treated teeth elevated above the control values at the initiation phase of treatment, but dropped below the control values at time of termination. And of electrically treated teeth, the values of the cathode sites were higher than those of the anode sites. 4. The rate of tooth movement in teeth . treated by force-electric combination increased with the length of treatment as compared to that treated by mechanical force alone.

  • PDF

A Safety Analysis of Electric Detonator for Stray Currents by Domestic Transmission Network System (국내 송전계통별 미주전류에 의한 전기뇌관의 안전성 분석)

  • Park Hyun-Sik;Kim Young-Seok;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.296-304
    • /
    • 2005
  • This study is to observe stray currents generated around the steel tower by domestic transmission network system and analysis stability of electric detonator. It is measured the stay current of each ten place at steel tower of 765 kV, 345 tV, 154 tV transmission line among domestic transmission network system. Stay currents measured a total of 40m at intervals of 4m toward a line direction and a line vertical direction centering around steel tower. Temperature of the surface, EC, water content also are measured. Although stay currents show the highest values, that is 12 percent of at 4m and less than 1 percent of 40m with Institute of Makers of Explosives(IME) regulations. It is shown correlation between stay currents and water content$\cdot$EC$\cdot$temperature of the surface. Stay currents measured at line direction and line vertical direction were little different and the shape of diminution was also shown a similar aspect.

A Study of Electromagnetic Interference in Power Line Communication (전력선 통신에서의 전자파 장해에 관한 연구)

  • Lee Jin-Taek;Chun Dong-Wan;Park Young-Jin;Lee Won-Tae;Shin Chul-Chai
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.12
    • /
    • pp.620-625
    • /
    • 2004
  • In this paper, we studied the emissive electric field due to the communication signal and the noise in medium voltage power-line. There are many types of conductive noise in power-line channel, which gives rise to radiation. And if the DMT carrier signal was excited, the current by this term was added to the current by noise and, generate radiation. We calculated input impedance by means of signal input network model of medium voltage power-line channel for calculating these currents. We calculated currents by input impedance and, calculated the emissive electric field by this calculated currents. From the measurement results, we knew that the measured results are very similar to the calculated results and if the input signal power level was higher than -40 dBm, the emissive electric field exceeds FCC radiation limit level 69.5 dB$\mu$V/m.