• Title/Summary/Keyword: electric current-voltage

Search Result 1,670, Processing Time 0.034 seconds

침수 누전에 대한 자계 특성

  • Kim, Tak-Yong;Lee, Gyeong-Seop;Kim, Jin-Sa;Kim, Chung-Hyeok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.147-147
    • /
    • 2009
  • Every year respect a countermeasure establishment the electric leakage detection system and electric leakage investigation work are becoming enforcement line plentifully in about the electric leakage accident which is increasing, measuring in compliance with a most ground connection voltage and an image electric current mainly is become accomplished, inputs a pulsation group signal in the line and detects a signal change between the line a method which there is. In order to investigate the quality in compliance with an electric leakage electric current from the electric leakage area after conferring the electric leakage environment in compliance with a flooding when the electric leakage electric current exists in the surface, it investigated the electric leakage electric current quality from the electric current distribution and flooded districts from the present paper.

  • PDF

Development of Super-capacitor Battery Charger System based on Photovoltaic Module for Agricultural Electric Carriers

  • Kang, Eonuck;Pratama, Pandu Sandi;Byun, Jaeyoung;Supeno, Destiani;Chung, Sungwon;Choi, Wonsik
    • Journal of Biosystems Engineering
    • /
    • v.43 no.2
    • /
    • pp.94-102
    • /
    • 2018
  • Purpose: In this study, a maintenance free super-capacitor battery charging system based on the photovoltaic module, to be used in agricultural electric carriers, was developed and its charging characteristics were studied in detail. Methods: At first, the electric carrier system configuration is introduced and the electric control components are presented. The super-capacitor batteries and photovoltaic module used in the experiment are specified. Next, the developed charging system consisting of a constant current / constant voltage Buck converter as the charging device and a super-capacitor cell as a balancing device are initiated. The proposed circuit design, a developed PCB layout of each device and a proportional control to check the current and voltage during the charging process are outlined. An experiment was carried out using a developed prototype to clarify the effectiveness of the proposed system. A power analyzer was used to measure the current and voltage during charging to evaluate the efficiency of the energy storage device. Finally, the conclusions of this research are presented. Results: The experimental results show that the proposed system successfully controls the charging current and balances the battery voltage. The maximum voltage of the super-capacitor battery obtained by using the proposed battery charger is 16.2 V, and the maximum charging current is 20 A. It was found that the charging time was less than an hour through the duty ratio of 95% or more. Conclusions: The developed battery charging system was successfully implemented on the agricultural electric carriers.

Electromagnetic Transient Program Modeling for Analysis of Switching Over-Voltage on Shunt Reactor (분로리액터 개폐 과전압 해석을 위한 EMTP 모델링)

  • Oh, SeungRyle;Jun, InYoung;Han, KiSun;Kang, JiWon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.393-397
    • /
    • 2020
  • Shunt reactor, a facility for reactive power compensation, is switched several times a day depending on the load pattern. When the circuitbreaker opens the shunt reactor over-voltage is generated by several factors which degrade the insulating performance of internal parts of the circuit-breaker and cause severe voltage stress on the equipment in the power system. Transient phenomenon occurring during the switching of shunt reactor are available in laboratories that verify the performance of the circuit-breaker by simulating the power system. However, it is difficult to measure the transient phenomenon that occurs during actual operation in actual power system due to many limitations. Therefore, this paper deals with the modeling using EMTP to analyze the reignition and current chopping which causes more severe transient recovery voltage in the small inductive current breaking in actual power systems. In addition, this paper analyzes the main phenomenon that cause circuit-breaker failure in opening shunt reactor using EMTP model.

Increase of resistive type superconducting fault current limiter capacity (박막 저항형 초전도 한류기의 용량증대를 위한 방안)

  • Cha, Sang-Do;Kim, H.R.;Choi, H.S.;Hyun, O.B.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.790-792
    • /
    • 2002
  • The resistive type superconducting fault current limiter(SFCL) is a current limiter using the Quench mechanism of superconductors. When Quench occurs in superconductors, the resistance of superconductors increases abruptly. In order to increase SFCL capacity, current limiting elements were connected in series. If the Quench current of each element was different, voltage distribution was imbalanced. This imbalance could be removed by arrangement including series and parallel connection of elements. Based on this result, an SFCL of 1.8kV/50A was designed and experimented, expecially, in terms of increasing the voltage rating.

  • PDF

An electric scooter development using BLDC motor (BLDC 전동기를 사용한 전기 스쿠터 개발)

  • Park, Seong-Wook;Lee, Deuk-Kee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.219-221
    • /
    • 2002
  • This paper presents an electric scooter development using blushless DC motor. In recent scooters was to develop for sport leisure and short transportation. Most of scooter are used petroleum gas. This gas scooter has disadvantage to pollute the air. Some of scooters have developed by DC motor which require a brush. However brushless motors have higher maximum speed and greater capacity, save maintenance labour and produce less noise. There is also greater freedom in planing the usage of brushless motors. In this paper we develop an electric scooter driving BLDC motor for design smart system and control speed of scooter with current reference signal to apply voltage to motor by means of three phase inverter. Using accelerator device we generate current reference to control speed and send the current to a MICOM by A/D converter. This MICOM produces the voltage signal and hall sensors signal and PWM controller drive three phase inverter to minimize error between the reference and an actual current.

The oscillation conduction characteristics of ZnO varistor fabricated with 3-composition seed grain method (3-성분 종입자법으로 제조한 저전압 ZnO 바리스터의 발진 전도특성)

  • 장경욱;김영천;황석영;김용주;이준웅
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1019-1026
    • /
    • 1996
  • In this study, we may be presented the carrier oscillation properties for the low-voltage varistor fabricated by a new method of three composition seed grain, in order to analyze the behavior of carriers at the its equivalent circuit model. The oscillation phenomena of carriers appeared from current-voltage characteristics under knee voltage is shown by the transient flow of nontrapped carriers group in the trap level of intergranular layer, surface state and/or depletion layer. In particularly, current oscillation phenomena is hardly shown in the high electric field. It is that the injected carriers from both electrodes are directly from the conduction band of forward biased ZnO grain through the intergranular layer into the reverse biased ZnO grain, because the trap level in the electric field above the knee voltage is mostly filled.

  • PDF

PWM Variable Carrier Generating Method for OEW PMSM with Dual Inverter and Current Ripple Analysis according to Zero Vector Position (듀얼 인버터 개방 권선형 영구자석 동기 전동기 제어를 위한 PWM 가변 캐리어 생성법 및 영벡터 위치에 따른 전류 리플 분석)

  • Shim, Jae-Hoon;Choi, Hyeon-Gyu;Ha, Jung-Ik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.279-285
    • /
    • 2020
  • An open-end winding (OEW) permanent magnet synchronous motor with dual inverters can synthesize large voltages for a motor with the same DC link voltage. This ability has the advantage of reducing the use of DC/DC boost converters or high voltage batteries. However, zero-sequence voltage (ZSV), which is caused by the difference in the combined voltage between the primary and secondary inverters, can generate a zero-sequence current (ZSC) that increases system losses. Among the methods for eliminating this phenomenon, combining voltage vector eliminated ZSV cannot be accomplished by the conventional Pulse Width Modulation(PWM) method. In this study, a PWM carrier generation method using functionalization to generate a switching pattern to suppress ZSC is proposed and applied to analyze the control influence of the center-zero vector in the switching sequence about the current ripple.

Harmonics Measurement of the Running Test EMU Train in Conventional Railway Lines (일반철도선로에서의 전동차 시험운행에 대한 고조파 측정연구)

  • Han, Seong-Ho;Shon, Jin-Geun;Kim, Young-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.77-83
    • /
    • 2016
  • The electric quality of train is represented by voltage and current harmonics at PT(Ratio 25,000/15/[V]) which is located between pantograph and primary winding of train transformer. In this paper, voltage and current harmonics were measured on the test EMU(electric multiple unit)train with maximum speed of 180km/h in existing railway lines(chungbuk, Taeback, Honam). As a results of test, it is found that the electric quality of train depends on the mostly operation conditions which is accelerating mode and braking mode on each sections. Voltage THD is above all 3[%] and current harmonics is monitored from lowest Harmonic to highest Harmonic in case of accelerating mode. But, highest current harmonics is not monitored in case of breaking mode. The results in this paper can help to stabilize the power device and power converter of the test EMU train.

Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway (도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Jongyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

Voltage Control Scheme in Synchronous Reference Frame for Improving Dynamic Characteristics in Parallel Operation of Double-Conversion UPSs (이중 변환 UPS 병렬 운전의 제어 동특성 향상을 위한 동기 좌표계 전압 제어기 구조)

  • Mo, Jae-Sing;Yoon, Young-Doo;Ryu, Hyo-Jun;Lee, Min-Sung;Choi, Seung-Cheul;Kim, Sung-Min;Kim, Seok-Min;Kang, Ho-Hyun;Kim, Hee-Jung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.283-290
    • /
    • 2022
  • This study proposes a voltage control scheme in a synchronous reference frame to improve the dynamic characteristics of double-conversion UPSs. UPSs need to control positive and negative sequence voltage, so that positive and negative sequence extractors are generally used to obtain each sequence of the voltage and current. Voltage and current controllers for each sequence are implemented. However, the extractor causes considerable delay, and the delay restricts the control performance, especially for the current controller. To improve the dynamics of the current controller, the proposed scheme adopts a unified current controller without separating positive and negative sequences. By using discrete-time current controller, the control bandwidth can be extended significantly so that negative sequence current can be controlled. To enhance the performance, an additional feed-forward technique for output voltage regulation is proposed. The validity of the proposed controller is verified by experiments.