유전체 비드를 이용한 수중 방전의 전계 분포 특성 평가 (The simulation on a electric field distribution of dielectric beads with a shape of ball in water)

  • 이동훈;박홍재;박재윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.15-18
    • /
    • 2003
  • In this paper, We explained the best shape design of electrode for discharge on the water. Electrode with rounding was reduced maximum electric field of over 40% to electrode without rounding for discharge on the water and the best shape of electrode for discharge on the water designed when shape of electrode had a curve radius of over $60^{\circ}$ at electrode's face to electrode's face with minimum distance and a curve radius of under $120^{\circ}$ at electrode's side face to electrode's front face. And When dielectric beads are used between electrodes, the life of electrodes is improved by lower stress of electric field on surface of electrodes.

  • PDF

고전압 전력기기응용을 위한 에폭시-나노콤포지트의 전기장 분산기술연구 (A Study on Electric Field Dispersion Techniques of Epoxy-Nanocomposites for Application of High Voltage Power Apparatus)

  • 이창훈;김효철;조영화;김현;정훈;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.97-97
    • /
    • 2010
  • A new electric application method was developed to prepare epoxy/organoclay nanocomposite for the electrical insulation in the AC electric fields and it could be also used in the field of various viscous polymer/organoclay systems. The applied AC electric field condition was as follows; (1) inter-electrode distance: 40 mm, (2) application voltage: 3-11 kV, (3) frequency: 60~1,000 Hz, and (4) application time: 0~60 min. To characterize the epoxy/clay nanocomposite, WAXS and TEM analyses were confirmed. In order to explain how the organic modifier affects the exfoliation phenomena, a mechanism of the oscillating collision of the quaternary ammonium head was proposed and the effects of the AC voltage and frequency and the organoclay content were studied.

  • PDF

유전율 이방성이 음인 액정을 이용한 Fringe-field Switching Twisted Hematic 모드의 전기광학 특성 연구 (Study on Electro-optic Characteristics of Fringe-field Switching Twisted Nematic Mode using a Liquid Crystal with Negative Dielectric Anisotropy)

  • 송일섭;신성식;이종문;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.530-535
    • /
    • 2004
  • We have studied 90$^{\circ}$ twisted nematic mode switching by fringe electric field(F-TN mode) using a liquid crystal (LC) with negative dielectric anisotropy. In the device, two polarizers are parallel each other, electrodes exist only on bottom substrate, and one of rubbing direction is coincident with polarizer axis. Therefore, the cell shows a black state before a voltage is applied. With a bias voltage generating fringe-electric field, the LC twists perpendicular to fringe electric field such that the LCs are almost homogeneously aligned except near the bottom surface since the negative type of the LC is used. Consequently, the new device exhibits much wider viewing angle than that of the conventional TN mode due to in-plane switching and relatively high transmittance since the LC director above whole electrode area aligns parallel to the polarizer axis.

Effective Channel Mobility of AlGaN/GaN-on-Si Recessed-MOS-HFETs

  • Kim, Hyun-Seop;Heo, Seoweon;Cha, Ho-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.867-872
    • /
    • 2016
  • We have investigated the channel mobility of AlGaN/GaN-on-Si recessed-metal-oxide-semiconductor-heterojunction field-effect transistors (recessed-MOS-HFET) with $SiO_2$ gate oxide. Both field-effect mobility and effective mobility for the recessed-MOS channel region were extracted as a function of the effective transverse electric field. The maximum field effect mobility was $380cm^2/V{\cdot}s$ near the threshold voltage. The effective channel mobility at the on-state bias condition was $115cm^2/V{\cdot}s$ at which the effective transverse electric field was 340 kV/cm. The influence of the recessed-MOS region on the overall channel mobility of AlGaN/GaN recessed-MOS-HFETs was also investigated.

Analysis of Partial Discharge Inception Voltages for the Wrong Positioning Defects in the Joint of Distribution Power Cables

  • Kim, Jeong-Tae;Kim, Dong-Uk;Lee, Young-Jo;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.977-982
    • /
    • 2012
  • In order to find out partial discharge (PD) phenomena in the cable joint due to the poor workmanship during the installation, the relationship between PD inception voltages and joint defects was investigated. For the purpose, in the joint of 22.9kV CNCV cables, electric fields were calculated for various semiconductive layer wrong positioning (WP) defects. And, PDIV were investigated through the experiments and compared with the results of electric field analysis. In all WP defect cases, the PD inception field calculated using measured PDIVs was similarly shown to be the average value of 1.84kV/mm. In addition, the calculated PDIV and the measured PDIV were almost equal, from the PDIV calculation using maximum electric fields and the measured PDIV for the normal case. Throughout this study, it is possible to analyze WP defects due to the poor workmanship and to establish better joint design for the distribution grade extruded cable system.

진공인터럽터 극간 랩거리 조정에 따른 각 부위의 전계값 계산을 통한 진공인터럽터 내부 절연파괴부위 예측 (Estimate of Flashover Position from E-field Calculation along Electrode Gap Distance)

  • 윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.23-23
    • /
    • 2010
  • Because of power consumption increase, global warming, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. In this paper, various models that short and long gap distance were used to analyze E field of each model. Calculation value was estimated of flashover position. As a result, short and long gap distance that vacuum interrupter inner between move electrode and fix electrode not coincided flashover position of each model. short gap distance estimated flashover position at electrode edge. but long gap distance model confirmed $E_{max}$ value at center shield. in this paper was compared electric field value. and estimated of flashover position from electric field calculation.

  • PDF

진공인터럽터 외부쉴드가 절연성능에 미치는 영향 분석 (An Analysis of Insulation Performance Result from Shield of Outside Vacuum interrupter)

  • 윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.100-100
    • /
    • 2010
  • Because of power consumption increase, global wanning, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. To improve the insulation performance, the high E field concentration phenomena was considered. Breakdown mechanism in vacuum is different from that in other insulation materials. therefore, It is necessary to understand the electric field distribution and insulation characteristics. This paper discusses the simulation and LI(light impulse) test of the shield of outside vacuum interrupter As a result, FEM simulation and LI test show that improve distribution of electrical field and equi-potential line. due to external shield. in this case, outside shield induced electric field of triple junction point.

  • PDF

케이블 접속재료의 전계분포 시뮬레이션 (Electric Field Distribution Simulation of the Cable Joint Materials)

  • 김형주;변두균;신종열;이덕진;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability, and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis, air void, silicone oil, of which may possibly exist real cables, are simulated by Electro 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materials. In the modeling, eclectic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

Y-cut $LiNbo_3$, Quartz, FR-4 기판을 이용한 마이크로스트립 안테나의 제작과 공진주파수 이동에 관한 연구. (Fabrication and Frequency Agile of Microstrip Antennas Using Y-cut $LiNbo_3$, Quartz and FR-4 Substrates.)

  • 이기세;;강현일;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.116-120
    • /
    • 2004
  • In this paper, we proposed a method to shift the resonant frequency by applying the electric field to microstrip patch antenna using piezoelectric substrates. We fabricated microstrip patch antenna using Y-cut LiNbO3, Quartz and FR-4 substrates. We designed and simulated the microstrip antennas by Ensemble V 7.0 of the simulation too1. We observed the resonant frequency by DC applied electric field in a microstrip patch antenna. When the electric field was 300 V/mm, the resonant frequency agile of Y-cut LiNbO3 microstrip patch antennas were 29 MHz. When the electric field was 400 V/mm, the frequency agile of X-cut, Y-cut and Z-cut quartz microstrip patch antennas were 55.2 MHz, 34.2 MHz and 28.0 MHz, respectively. However, when the electric field was 400 V/mm, the resonant frequency of FR-4 microstrip patch antenna does not changed. It was shown that the resonant frequency agile of Y-cut and Z-cut quartz microstrip patch antennas are due to piezoelectric phenomenon not to be permittivity.

  • PDF

Polarity Effects of Dielectric Anisotropy on Electro-Optical Characteristics of Fringe Field Twisted Nematic Mode

  • Shin, Sung-Sik;Jhun, Chul-Gyu;Kim, Woo-Young
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.288-288
    • /
    • 2009
  • We have studied polarity effects of dielectric anisotropy effects on electro-optical characteristics of a twisted nematic mode driven by fringe electric field, which has wide viewing angle characteristics. Our device is designed as normally black mode between parallel polarizers. The perfect polarization conversion of incident light, which passes through a polarizer, is achieved, when it passes through the twisted liquid crystal (LC) layer. If an electric field is applied, the LC molecules with a positive (or negative) dielectric anisotropy rotate parallel (or perpendicular) to the horizontal component of a fringe electric field as increasing transmittance. From the calculated results, enhanced transmittance of the fringe field-twisted nematic (FF-TN) mode with positive dielectric anisotropy of + 8.2 can be obtained.

  • PDF