• Title/Summary/Keyword: elbow rehabilitation robot

Search Result 14, Processing Time 0.016 seconds

Development of a Chest-wearable Walking Rehabilitation Robot (가슴 착용형 보행 재활로봇의 개발)

  • Kim, Hyun;Kwon, Jeong-Gwan;Song, Sang-Young;Kang, Seok-Il;Kim, Jung-Yup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.5
    • /
    • pp.393-400
    • /
    • 2015
  • This paper describes the development of a chest-wearable robot that can efficiently perform self walking rehabilitation without a helper. The features of the developed robot are divided into three parts. First, as a mechanical characteristic, the conventional elbow crutch is attached at the forearm. However, the proposed robot is attached to the patient's chest, enabling them to feel free to use their hands and eliminate the burden of the arms. Second, as a characteristic of the driving algorithm, pressure sensors attached to the chest automatically perceive the patient's walking intention and move the robot-leg thereafter. Also, for safety, it stops operating when an obstacle is found in front of the patient by using ultrasonic sensors and generates a beeping sound. Finally, by using the scotch yoke mechanism, supporting legs are moved up and down using a rotary servo motor without excessive torque that is generated by large ground reaction forces. We showed that the developed robot can effectively perform self walking rehabilitation through walking experiments, and its performance was verified using Electromyograph (EMG) sensors.

Water-jet Cleaning Motion of the In-Pipe Robot with Screw Drive Inside the Water Pipes

  • Kang, Hoon;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.7
    • /
    • pp.894-901
    • /
    • 2012
  • For more efficient use of the high pressure water-jet in rehabilitation of the water pipes, we have studied the water-jet cleaning motion of the in-pipe robot with screw drive. The mathematical models of the water-jet in the straight and the curved pipe (90 degrees elbow), representative features of the water mains, were designed to understand the water-jet motion and simulations have been performed. Furthermore the experiments has been conducted to validate the simulations by using the prototype in-pipe robot in the 3-D pipeline. The simulation results show that the water-jet motion in the straight pipe has a constant water-jet interval, whereas the motion in the curved pipe is changed by its position. By the comparison of the simulation and the experimental results, we have demonstrated that the simulations successfully estimate the water-jet motion inside the water pipes. Therefore in-pipe robot operators can predict a water-jet motion for a target water pipe through the simulation and flexibly make a proper water-jet motion by changing the robot configurations before a cleaning work.

Redundant Design of Wearable Robot Mechanism for Upper Arm (여자유도를 이용한 상지 착용형 로봇의 메커니즘 설계)

  • Lee, Young-Su;Hong, Sung-Jun;Jang, Hye-Yeon;Jang, Jae-Ho;Han, Chang-Su;Han, Jung-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.134-141
    • /
    • 2009
  • Recently, many researchers have tried to develop wearable robots for various fields such as medical and military purposes. We have been studying robotic exoskeletons to assist the motion of persons who have problems with their muscle function in daily activities and rehabilitation. The upper-limb motions (shoulder, elbow and wrist motion) are especially important for such persons to perform daily activities. Generally for shoulder motion 300F is needed to describe its motion(extension/flexion, abduction/adduction, internal/external rotation) but we have used a redundant actuator thus making a 4 DOF system. In this paper, we proposed the mechanism design of the exoskeleton which consists of 4-DOF for shoulder and 1-DOF for elbow robotic exoskeleton to assist upper-limb motion. Then we compared the new mechanism design and prototype mechanism design. Here we also analyze the proposed system kinematically to find out and to avoid the singular point. This research will ensure that the proposed wearable robot system make human's motion more powerfully and more easily.

Short-term Effect of Robot-assisted Therapy on Arm Reaching in Subacute Stroke Patients (상지로봇치료가 아급성기 뇌졸중 환자의 팔뻗기 움직임에 미치는 단기 효과)

  • Hong, Won-Jin;Kim, Yong-Wook;Kim, Jongbae;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.4
    • /
    • pp.79-91
    • /
    • 2018
  • Objective : The purpose of this study was to investigate the short-term effect of robot-assisted therapy to improve upper extremity function in subacute stroke. Method : This study was a retrospective study using the medical record. The subjects were 20 patients who were diagnosis with stroke within 6 months. All patients received general rehabilitation intervention during the experimental period and robot-assisted therapy and task-oriented training. Robot assisted therapy was composed of 1 sessions, 1hour per person and task-oriented training was same. For result analysis, descriptive statistics, paired t-test were used. Results : After intervention, all participants got 3D motion analysis about reaching. For the result, there was statistically significant improvement in smoothness in robot assisted therapy(p<.05). there was no statistically significant difference between robot assisted therapy and task-oriented training in speed, time. In this result, we knew the robot assisted therapy can short term effect in elbow joint during arm reaching. Conclusion : Robot assisted therapy is considered as alternative choice in clinical occupational therapy for improving upper extremity function in subacute stage stroke patients.