• 제목/요약/키워드: effluent water

검색결과 1,209건 처리시간 0.027초

낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석 (Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin)

  • 조현경;김상민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.493-493
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of the sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. The flow and water quality such as BOD, COD, SS, T-N, and T-P data for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS and T-P were correlated positively with river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluent and downstream stream, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between river flow rate and water quality factors (COD, SS, TP) was high for river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

  • PDF

Potential Water Retention Capacity as a Factor in Silage Effluent Control: Experiments with High Moisture By-product Feedstuffs

  • Razak, Okine Abdul;Masaaki, Hanada;Yimamu, Aibibula;Meiji, Okamoto
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권4호
    • /
    • pp.471-478
    • /
    • 2012
  • The role of moisture absorptive capacity of pre-silage material and its relationship with silage effluent in high moisture by-product feedstuffs (HMBF) is assessed. The term water retention capacity which is sometimes used in explaining the rate of effluent control in ensilage may be inadequate, since it accounts exclusively for the capacity of an absorbent incorporated into a pre-silage material prior to ensiling, without consideration to how much the pre-silage material can release. A new terminology, 'potential water retention capacity' (PWRC), which attempts to address this shortcoming, is proposed. Data were pooled from a series of experiments conducted separately over a period of five years using laboratory silos with four categories of agro by-products (n = 27) with differing moisture contents (highest 96.9%, lowest 78.1% in fresh matter, respectively), and their silages (n = 81). These were from a vegetable source (Daikon, Raphanus sativus), a root tuber source (potato pulp), a fruit source (apple pomace) and a cereal source (brewer's grain), respectively. The pre-silage materials were adjusted with dry in-silo absorbents consisting wheat straw, wheat or rice bran, beet pulp and bean stalks. The pooled mean for the moisture contents of all pre-silage materials was 78.3% (${\pm}10.3$). Silage effluent decreased (p<0.01), with increase in PWRC of pre-silage material. The theoretical moisture content and PWRC of pre-silage material necessary to stem effluent flow completely in HMBF silage was 69.1% and 82.9 g/100 g in fresh matter, respectively. The high correlation (r = 0.76) between PWRC of ensiled material and silage effluent indicated that the latter is an important factor in silage-effluent relationship.

공공하수처리시설 방류수 TOC에 영향을 주는 요인 분석 (Analysis of factors affecting effluent TOC in publicly owned treatment works)

  • 강성주;강병준;박규홍;정동환;이원석;정현미
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.141-150
    • /
    • 2019
  • Total organic carbon(TOC) was introduced as the water quality index of the rivers and lakes in 2013. This paper evaluated factors affecting effluent TOC concentrations and treated and discharged loads of existing publicly owned treatment works(POTWs). For selected POTWs with greater treatment capacity than $500m^3/day$, factorial analysis was used to consider effects of kinds of biological treatment processes, inflow of other types of wastewater(industrial, livestock, landfill leachate wastewater, etc.) with domestic wastewater, sewer separation rate, and effluent discharging zones in which different effluent criteria applied. As a result, those factors did not show significant effect on effluent TOC concentration of POTWs in effluent discharging zone I and II. However, In effluent discharging zone III and IV, kinds of biological treatment processes, the inclusion of other waste in influent of domestic wastewater, and the sewer separation rate were significant factors. The treated TOC load in POTWs was also not affected significantly by the variables set in this study. On the other hand, those three factors influenced significantly on the TOC load discharged to water bodies. The sum of factorial effects and the contribution rate of three factors to the discharged TOC load was 60.23 and 41%, 59.57 and 41%, and 42.04 and 18%, respectively.

Thermal Effluent through Extruded Side Channel

  • Yoon, Tae-Hoon;Yook, Woon-Soo;Yi, Young-Kon
    • Korean Journal of Hydrosciences
    • /
    • 제6권
    • /
    • pp.67-79
    • /
    • 1995
  • The reattachment of buoyant efflluent to a shore in a crossflow is investigated experimentally. The effluent is prodeced by discharging heated water through a projected side channel into a confined crossflow of the same depth. In the projecting effluent, the size of recirculating region, which is formed by deflected thermal plume on the lee of the effluent, tends to increase, but the maximum temperature decreases in the direction of the crossflow and it has more uniform transverse spreading compared to non-projected type. The heat flux across the crossflow is found to be independent of the projceted length of the side channel under relatively high buoyancy flux on the contrary to low buoyancy flux. The reattachment of th effluent can be specified by both velocity ratio and densimetric Froude number, whereas only the velocity ratio is governing factor to the reattachment of the effluent in the case of non-projecting type.

  • PDF

우리나라 공공하수처리시설의 TOC 배출특성 및 관리방안 연구 (Characteristics of TOC in effluent discharge from public sewage treatment works in korea)

  • 정동환;최인철;조양석;안경희;정현미;권오상;박후원;신현상;허진
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.657-668
    • /
    • 2014
  • Under Korea's Enforcement Decree of the Framework Act on Environmental Policy amended in 2013, total organic carbon (TOC) is newly added as water quality parameter to assess organic pollution in water and aquatic ecosystem. To meet the TOC requirement and improve quality of effluent discharged into public watershed, it is also necessary to develop standards for TOC in effluent from public sewage treatment works (PSTWs). In this study, we reviewed the characteristics and removal efficiency of TOC in influent and effluent of PSTWs. The study found that phosphorus treatment process removed not only soluble phosphorus but also a portion of TOC remaining after the secondary treatment process. TOC concentration in effluent from PSTWs operated in tandem with industrial wastewater treatment work was higher due to influx of insoluble substances from the industrial wastewater treatment work. In order to lay a foundation for the management of TOC from PSTWs, it is necessary to carry out research on TOC from different perspectives. For example, studies on the generation mechanism of TOC and the impact of TOC on drinking water resources, assessment of effluent qualities through monitoring, and development of measures to control TOC for the preservation of aquatic ecosystem are needed.

간접방류사업장 관련 폐수의 생태독성수준 및 특성 평가 (Evaluation of Ecotoxicity and Characteristics on Indirect Effluents and Related Wastewater)

  • 김종민;신기식;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.481-486
    • /
    • 2017
  • This paper aims to evaluate the characteristics of direct and indirect effluents'toxicity level and difference between two test durations (24 h and 48 h) of test method. The proportion of the indirect effluent samples which exceeded the ecotoxicity permit limitations (TU 1 or TU 2) showed more than 2 times higher than that of direct effluent samples. However, effluent toxicity of Wastewater Treatment Plants (WTPs) indicated less than TU 1 regardless of influent toxicity. From this results, treatment process was thought to have a good efficiency. WTP Salinity was very similar between influent and effluent. This trend could be reconfirmed by the component ratio of ion concentration between them and $Na^+$, $SO_4^{2-}$, $C^-$ lions which have a greater percentage than other ions. In addition, in case of high salinity, toxicity value also showed high level. To judge from above results, indirect effluents which were exempted from application of ecotoxicity standards, may need a new effluent limitations regardless of the treatment efficiency of WTP. According to circumstances, effective countermeasure may need to restrain the discharge of salinity-contained effluents which came from indirect-effluent factories. Test duration comparative study indicated that 48 h results were higher toxicity (exceeding rate of ecotoxicity criteria) than 24 h by the 5 to 5.4 percentage. 24 h test duration seemed to be useful in case of rapid detection, whereas 48 h test method could be applied for reinforcement of ecotoxicity regulatory system.

하수처리수 방류 하천의 물환경과 저서성 대형무척추동물 군집 생태 연구 (A Study on Water Environment and Benthic Macroinvertebrate Community in Reclaimed Wastewater Effluent Dominated Stream)

  • 손정원;곽진숙;조갑제;류동춘
    • 한국물환경학회지
    • /
    • 제37권3호
    • /
    • pp.190-203
    • /
    • 2021
  • Water quality, benthic macroinvertebrate communities, and other factors were investigated to explore the effects of the effluent discharge from a sewage treatment plant into Jwagwang stream in Busan in 2019. During the study period, the flow rate of this stream was in the range of 10,400 m3/day to 52,200 m3/day except for the discharge of about 24,000 m3/day of the effluent. After discharge, the flow velocity increased by about 65% and the water depth increased by about 40%. At sites downstream of the discharge point, BOD, COD, TOC, T-N, T-P, and other water quality values were worse than those of the upstream sites. The periphytic algal chlorophyll-a concentrations in the natural substrata were higher than those of the upstream sites, especially in May and August. However, at sites downstream of the discharge point, the individual numbers of Annelida were decreased and individual numbers of the insecta of arthropoda were increased. Also, species numbers and the diversity and dominance indexes were improved in the sites downstream of the discharge point. The functional feeding groups (FFGs) of collector-filterers were increased and the habitat orientation groups (HOGs) of sprawlers, burrowers, and clingers were especially increased at the sites with additional reclaimed wastewater effluent flow. Regardless of the effluent discharge, BMI, an indicator of ecological stream health using benthic macroinvertebrate species, did not show large gaps between the study points. Although the water quality of the sites downstream of the discharge point was much worse than those upstream, their ecosystem soundness was better than those of the upstream sites from an ecological perspective.

수온 변화의 영향을 고려한 방류관 플룸의 혼합역 분석 (Mixing Zone Analysis on Outfall Plume considering Influent Temperature Variation)

  • 김지연;이중우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.247-253
    • /
    • 2004
  • As a large scale port development in coastal waters proceeds step by step and populations in the vicinity of port are getting increased, the issue on "how to dispose the treated municipal water and wastewater in harbor" brings peoples′ concern. The submarine outfall system discharges the primary or secondary treated effluent at the coastline or in deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding sea water and becomes very dilute. We intended in this paper to investigate the impact on dilution of effluent and the behavior of flume under the conditions of the seasonal and spatial temperature variations, which have not been noticeable in designing effective marine outfall system. To predict and analyze the behaviour and dilution characteristics of plume not just with the effluent temperature, but also with the seasonal variation of temperature of surround water and tidal changes, CORMIX(Cornell Mixing Zone Expert System)-GI have been applied. The results should be used with caution in evaluation the mixing zone characteristics of discharged water. We hope to help for the effective operation of outfall system, probable outfall design, protection of water quality, and warm water discharges from a power plant, etc.

  • PDF

물 부족국가에서 활용가능한 정화조의 최적모형 개발 (Development of Optimal Septic Tank in the Countries of Water Shortages)

  • 임봉수;경해룡
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

산업폐수에 대한 이화학적 분석과 물벼룩 생태독성의 비교 (Comparison between Ecotoxicity using Daphnia magna and Physiochemical Analyses of Industrial Effluent)

  • 이선희;이학성
    • 한국환경과학회지
    • /
    • 제23권7호
    • /
    • pp.1269-1275
    • /
    • 2014
  • Ecotoxicity assessments with the physiochemical water quality items and the bioassay test using Daphnia magna were conducted for 18 selected effluents of 6 industrial types (metal processing, petroleum refining, synthetic textile manufacturing, plating, alcohol beverage manufacturing, inorganic compound manufacturing) being detected toxicity from industrial effluent in Ulsan city, and the interrelationship between total toxic unit (${\Sigma}TU$) and concentrations of Water Quality Conservation Act in Korea were investigated. The average toxic unit(TU) of effluents for 6 industrial types displayed the following ascending order: petroleum refining (0.2) < synthetic textile manufacturing (0.6) < alcohol beverage manufacturing (0.9) < metal processing (1.3) ${\leq}$ inorganic compound manufacturing (1.3) < plating (3.0). These values were less than effluent permission standard. Based on the result of substances causing ecotoxicity, the correlation analysis was not easy because most of heavy metals were not detected or were less than effluent permission standard. Toxicological assessment of industrial effluent was suitable for the evaluation of the mixture toxicity for pollutant. The whole effluent toxicity test using a variety of species was needed for the evaluation of industrial wastewater.