• Title/Summary/Keyword: effluent water

Search Result 1,210, Processing Time 0.036 seconds

Influence of Pipe Materials and VBNC Cells on Culturable Bacteria in a Chlorinated Drinking Water Model System

  • Lee, Dong-Geun;Park, Seong-Joo;Kim, Sang-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.9
    • /
    • pp.1558-1562
    • /
    • 2007
  • To elucidate the influence of pipe materials on the VBNC (viable but nonculturable) state and bacterial numbers in drinking water, biofilm and effluent from stainless steel, galvanized iron, and polyvinyl chloride pipe wafers were analyzed. Although no HPC (heterotrophic plate count) was detected in the chlorinated influent of the model system, a DVC (direct viable count) still existed in the range between 3- and 4-log cells/ml. Significantly high numbers of HPC and DVC were found both in biofilm and in the effluent of the model system. The pipe material, exposure time, and the season were all relevant to the concentrations of VBNC and HPC bacteria detected. These findings indicate the importance of determining the number of VBNC cells and the type of pipe materials to estimate the HPC concentration in water distribution systems and thus the need of determining a DVC in evaluating disinfection efficiency.

Safety Investigation of Tap Water and Biofilm by Isolated Bacteria (수돗물과 생물막의 세균분포를 통한 안전성 조사)

  • Lee, Dong-Geun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.207-213
    • /
    • 2004
  • For investigation of the food safety and influence of biofilm on the bacterial quality of tap water, it was detected by selective media, and identified by API kit and MIDI system. Biofilm and effluent showed much more colonies than influent. Although there were many presumptive positive colonies, no pathogenic bacterium detected. However opportunistic pathogens, such as Pseudomonas aeruginosa and Aeromonas species, and members of family Enterobacteriaceae were detected. Compared to influent, biofilm and effluent showed more diverse bacteria. This study implies that there would be the negative influence of biofilm on the bacterial qualities of tap water.

Study on Microorganism Multiplication Behavior and Efficiency of Chlorine Disinfection in the Sewage Effluent from J Municipal Waste Water Treatment Plant (J 하수 처리장 방류수 중 세균의 성장 거동 및 염소 소독 효율 고찰)

  • Lee, Ungi;Lee, Yoonjin;Jeong, Kyuyean
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.122-128
    • /
    • 2008
  • We evaluated the relationship between the multiplication of heterotrophic microorganisms and physicochemical factors in the final discharged sewage water from J municipal waste water treatment plants. Dissolved organic carbon (DOC) was the most crucial factor influencing multiplication of heterotrophic plate counts (HPC) among the water quality variables selected. Degrading bacteria, such as proteolytic bacteria, lipholytic bacteria, starch degrading bacteria, cellulolytic bacteria, and pectinolytic bacteria, were monitored to understand the condition of nutrients in finished sewage effluent. The percentages of lipid and protein combined occupied 81% in finished sewage water. The multiplication of HPC showed the highest value in August. The formation of trihalomethane (THM) was low in the finished discharge water during chlorine disinfection, which was $71{\mu}/L$ (which was less than $100{\mu}/L$- the standard of drinking water quality) with 10 mg/L of chlorine during 15 min.

Acute and Chronic Ecotoxicity Assessment of Ambient and Effluent Water Discharged to the Lake Shihwa (시화호로 유입되는 지표수 및 방류수의 급·만성 생태독성평가)

  • Ji, Kyunghee;Jang, Shinhye;Kim, Youngsook;Kim, Eunjoo;Kim, Jiyoung;Seo, Eunjung;Park, Yoonsuk;Park, Sujung;Choi, Kyungho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.144-154
    • /
    • 2007
  • The acute and chronic toxicity of ambient and effluent water discharged to Lake Shihwa were investigated by using Vibrio fischeri, Daphnia magna and Oryzias latipes. Physicochemical characteristics including biochemical oxygen demand (BOD) and nine heavy metals in a total of 15 water samples were evaluated and were satisfied with relevant Korean Water Quality Standards (KWQS) except for Hg in one sample. Acute toxicity was observed in five samples collected from three sampling locations. When impacts on reproduction and growth after chronic exposure were evaluated with D. magna, all the samples showed significant chronic effects. Reproduction appeared relatively more sensitive endpoint. In 21 days chronic tests on O. latipes, survival, mean egg number per female per day, hatching success rate and time to hatch were affected by increasing sample concentration. The organ-level changes such as gonadosomatic index (GSI), and hepatosomatic index (HSI), and molecular biomarker of vitellogenin (Vtg) induction that evaluated with O. latipes increased as exposure concentrations increased. It is noteworthy that the samples that did not exceed the KWQS resulted in acute and chronic toxicities. The results suggested that numeric criteria based on physicochemical parameters may not be protective of aquatic ecosystem. Acute and chronic toxicity tests with organisms representing different trophic groups should be supplemented in order to provide adequate level of environmental protection.

A review on status of organic micropollutants from sewage effluent and their management strategies (하수 유래 미량오염물질 현황과 관리 방안 고찰)

  • Choi, Sangki;Lee, Woongbae;Kim, Young-Mo;Hong, Seok-Won;Son, Heejong;Lee, Yunho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.205-225
    • /
    • 2021
  • Due to the large-scale production and use of synthetic chemicals in industralized countries, various chemicals are found in the aquatic environment, which are often termed as micropollutants. Effluents of municipal wastewater treatment plants (WWTPs) have been identified as one of the major sources of these micropollutants. In this article, the current status of occurrence and removal of micropollutants in WWTPs and their management policies and options in domestic and foregin countries were critically reviewed. A large number of pharmaceuticals, personal care products, and industrial chemicals are found in WWTPs' influent, and are only partially removed by current biological wastewater treatment processes. As a result, some micropollutants are present in WWTPs' effluents, which can negatively affect receiving water quality or drinking water source. To better understand and assess the potential risk of micropollutants, a systematic monitoring framework including advanced analytical tools such as high resolution mass spectrometry and bioanalytical methods is needed. Some Western European countries are taking proactive approach to controlling the micropollutants by upgrading WWTP with enahnced effluent treatment processes. While this enahnced WWTP effluent treatment appears to be a viable option for controlling micropollutant, its implementation requires careful consideration of the technical, economical, political, and cultural issues of all stakeholders.

NO3-N Removal of A Reed Wetland Cell Constructed for Purifying Effluent from A Night Soil Treatment Plant During Its Initial Operating Stage (분뇨처리장 방류수정화 갈대습지셀의 초기운영단계 질산성질소 제거)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.5
    • /
    • pp.100-106
    • /
    • 2004
  • $NO^3$-N removal was examined from July 2002 to December 2002 of a surface-flow constructed treatment wetland cell, which was a part of a treatment wetland system composed of four wetland cells and one distribution pond. The system was established on rice paddy near the Kohung Estuarine Lake located at the southern part of the Korean Peninsula. The lake and the paddy were formed by a salt marsh reclamation project. Effluent from a secondary-level treatment plant was funneled into the system. The investigated cell was created in June 2002. Its dimensions were 87 m in length and 14 m in width. It had an open water zone at its center, which was equivalent to 10 percent of its total area. Reeds(Phragmites australis) were transplanted from natural wetlands into the cell and their stems were cut at about 40 cm height from their bottom ends. Average 25 $m^3$/day of effluent from the plant was funneled into the cell by gravity flow and average 24.2$m^3$/day of its treated effluent was discharged into the Sinyang Stream flowing into the lake. Its water depth was maintained about 0.2 m and its hydraulic detention time averaged 5.2 days. The average height of the reed stems was 45.2 cm in July 2002 and 80.5 cm in September 2002. The number of stems averaged 40.3 stems/$m^2$ in July 2002 and 74.5 stems/$m^2$ in September 2002. The reeds were established initially well. $NO_3$-N loading rate of influent and effluent averaged 173.7 and $93.5mg/m2{\cdot}day$, respectively. Removal of $NO_3$-N averaged $80.2mg/m2{\cdot}day$ and its removal rate by mass was about 50 %. Considering the initial operation of the cell and the inclusion of the cold months of November and December in the analysis period, the $NO_3$-N removal rate was good.

Effect of antibiotic resistant factors in effluent of wastewater treatment plant on stream (하수처리장 방류수에 존재하는 항생제 내성인자가 하천에 미치는 영향)

  • Jang, Yejin;Yoo, Yong-Jae;Sul, Woo Jun;Cha, Chang-Jun;Rhee, Ok-Jae;Chae, Jong-Chan
    • Korean Journal of Microbiology
    • /
    • v.53 no.4
    • /
    • pp.316-319
    • /
    • 2017
  • The antibiotic resistant genes (ARG) and mobile genetic elements (MGE) were investigated with the effluent of waste-water treatment plant (WWTP), and river waters of upstream and downstream in order to elucidate the effect of effluent on antibiotic resistance in a natural river. Total numbers of 134~183 of ARG and MGE were detected and the abundance of ARG and MGE was 0.063~0.422 copies per one of 16S rRNA gene in three water samples. Effluent sample contained the highest amount of the total number and abundance of ARG and MGE whereas total viable cells were observed in the lowest amount among the three samples. This indicated that the genes were originated from cells died during the wastewater treatment process. In addition, the co-relationship of abundance between ARG and MGE suggested that acquired resistance was a prevalent mechanism among the antibiotic-resistant bacteria existing in WWTP.

Analysis of Korean TMLD Design Flow Variation due to Large Dam Effluents and Water Use Scenarios

  • Shin, Hyun-Suk;Kang, Doo-Kee;Kim, Sang-Dan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.74-83
    • /
    • 2007
  • The goal of this study is to establish an integrated watershed hydrologic model for the whole Nakdong River basin whose area is an approximately 24,000 km2. Including a number of watershed elements such as rainfall, runoff, water use, and so on, the proposed model is based on SWAT model, and is used to improve the flow duration curve estimation of ungauged watersheds for Korean Total Maximum Daily Load (TMDL). The model is also used to recognize quantitatively the river flow variation due to water use elements and large dam effluents in the whole watershed. The established combined watershed hydrologic model, SWAT-Nakdong, is used to evaluate the quantified influences of artificial water balance elements, such as a dam and water use in the watershed. We apply two water balance scenarios in this study: the dam scenario considering effluent conditions of 4 large multi-purpose dams, Andong dam, Imha dam, Namgang dam, and Habcheon dam, and the water use scenario considering a water use for stream line and the effluent from a treatment plant. The two scenarios are used to investigate the impacts on TMDL design flow and flow duration of particular locations in Nakdong River main stream. The results from this study will provide the basic guideline for the natural flow restoration in Nakdong River.

  • PDF

A Study on the Diatomaceous Earth Filtration of Settling Basin Effluent (정수장 침전지 유출수의 규조토 여과에 관한 연구)

  • Shin Dae-Yewn;Ji Sung-Nam;Moon Ok-Ran;Kim Ji-Yeong;Suh Dong-Woo;Cho Young-Kwan
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.410-416
    • /
    • 2004
  • The objective of this investigation was to evaluate applicability of precoat filtration that can be substituted for rapid sand filter of conventional water treatment system(CWTS). Precoat filter used in this experiment are candle filter. Element disk of candle are pore size $10{\mu}m(R),\;20{\mu}m(B)$ And diatomaceous earth are cake pore size $3.5{\mu}m$(Standard Super- Cel; A), $7{\mu}m$(Hyflo Super-Cel; B) and $17{\mu}m$(Celite 545RV; C). $2kg/m^2$ diatomaceous earth is used for precoating, it coated candle in $5{\sim}6mm$ thickness. 1. Al adsorption dosages by diatomaceous earth used in experimental we Hyflo Super-Cel 0.843mg/g, Standard Super-Cel 0.782 mg/g and Celite 545RV 0.766 mg/g. 2. Filtrate of precoat filter during 60min are R-C combination 20.7($m^3/m^2$)>B-C 18.3($m^3/m^2$)>B-B 15.0($m^3/m^2$)> R-B 12.9($m^3/m^2$)> R-A 11,093($l/m^2$). 3. Water quality of precoat filter effluent are thus. $KMnO_4$ consumption are $1.10{\sim}2.20mg/l$, removal rate are $30.9{\sim}65.6\%$. They are R-A 1.10(mg/l)(removal rate $65.6\%$). R-C(2.20 mg/l)(removal rate $30.9\%$). 4. $Al^{3+}$ are not detected with all combination, removal rate $100\%$. 5. Considering water quality and flux, continued running time of R-A combination is 7 hr. Accumulated filtrate are $74.4 m^3/m^2$, average flux is $177.2 l/m^2{\cdot}min$. And filtrate per diatomaceous earth 1g are 37.2 l. 6. R-A effluent's water quality are $KMnO_4$ Consumption 1.10(mg/l), DOC 1.161 mg/1, Al 0.0 mg/1, $UV_{254}$ 0.016/cm, Turbidity 0.1(NTU). R-A combination is suitable to precoat filtration for the settling basin effluent treatment.