• Title/Summary/Keyword: effluent water

Search Result 1,209, Processing Time 0.031 seconds

Analysis of Water Quality Components and Antibiotics in the Final Effluent of Wastewater Treatment Facilities in the Nakdong River Basin (낙동강 유역에 위치한 폐수처리시설 최종방류수의 수질과 항생물질 분석)

  • Park, Kyeong-deok;Kang, Dong-hwan;Jo, Won Gi;Yu, Hun Sun;Yoon, Yeon Su;Kim, Byung-Woo
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.857-870
    • /
    • 2020
  • In this study, the antibiotic components in the final effluent from the 12 wastewater treatment facilities located in the Nakdong River basin were investigated, and the correlation between organic matters, nutrients and antibiotics was analyzed. In the final effluent of the wastewater treatment facilities, three sulfonamides antibiotics (sulfamethazine, sulfathiazole, sulfachlorpyridazine) and tetracyclines antibiotics (oxytetracycline, doxycycline) were detected. Sulfamethazine were detected at all points and ranged from 10.398 to 278.784 ng/L. Sulfathiazole were detected at 6 points (Andong, Gumi, Hapcheon, Miryang, Uiryeong, Haman), and ranged from 23.773 to 144.468 ng/L. The correlation coefficients between sulfathiazole and TSS, COD, TOC, NH3-N, NO2-N, and T-N components were high in the range of 0.73 to 0.92. The correlation coefficient between sulfamethazine and T-N was 0.48, and the correlation with the rest of the water quality components was low. The correlation coefficient between sulfamethazine and sulfathiazole was 0.78. Through this study, it was confirmed that the concentration of sulfonamides antibiotics was higher than the concentration of tetracyclines antibiotics in the final effluent of 12 wastewater treatment facilities in the Nakdong River basin, and the concentration of sulfathiazole increased with organic matters and nutrients.

Biologic Effect of Effluents from Shipyard and the Adjacent Stream Water on Four Cultured Organisms (조선소 배출수 및 주변 하천수의 생물독성)

  • Seo, Jin-Young;Kim, Gi-Beum;An, Joon-Geon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.187-192
    • /
    • 2006
  • In order to know the biological effect of effluent from shipyard and the adjacent stream water on four organisms (flatfish, rockfish, sea squirt and arkshell) cultured around the shipyard, lethal rate and DNA damage were measured after 48 hr exposure and carried out by a single cell gel electrophoresis, namely comet assay. $LC_{50}$ (48 hr) could not be calculated in any organism 48 hours after exposure to effluent from shipyard and stream water, because all organism showed a lethal rate lower than 20%. Regardless of no acute toxicity, DNA damage of flatfish and rockfish was detected higher in Jang-Pyoung stream than in control, whereas sea squirt revealed higher DNA damage in laundry waste water. From these results, Jang-Pyoung stream seemed to have a relatively higher genotoxicity rather than effluent from shipyard.

  • PDF

Assessment of Korean Water Quality Standards for Effluent Discharged from the Dye Industry Based on Acute Aquatic Toxicity Tests Using Microbes and Macroinvertebrates (염색폐수의 수질독성시험을 이용한 한국의 수질배출허용기준 평가연구)

  • Kim, Young-Hee;Lee, Min-Jung;Choi, Kyung-Ho;Eo, Soo-Mi;Lee, Hong-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2004
  • Acute aquatic toxicity of effluents discharged from five dyeing plants in Gyeong-gi province were evaluated to assess whether the current Korean water quality standards(KWQS) could protect aquatic life. Chemical analyses of all parameters regulated under KWQS, except for E-coli, were also carried out to determine regulation compliance of the samples. All the effluent samples were satisfied with KWQS except for the color in only one sample. In acute Daphnia magna toxicity tests, significant mortality was observed in one of five samples and EC50 was 12.1%(95% confidence interval 9.1-16.2), which was in compliance with KWQS. The result of the Microtox assay indicated that acute microbial toxicity existed in effluents from three out of five plants, two of which were in compliance with KWQS. The agreement between regulation compliance of chemical concentrations of effluent and observed toxicity from various biological toxicity tests was very poor to fair (kappa = 0.194~0.250). The data presented suggest that exposure to dyeing wastewater which were in compliance with Korean water quality standards may not be safe to aquatic biota, and multiple tropical levels should be considered in aquatic toxicity monitoring of dyeing industry.

Water Purification and Ecological Restoration Effects of Sustainable Structured Wetland Biotop (SSB) System Established in the Habitat of the Endangered Species -Exemplified by An-teo Reservior Ecological Park in the Habitat of the Gold-spotted Pond Frog - (멸종위기종 서식처에 조성된 생태적 수질정화 비오톱 시스템의 수질정화 및 생태복원 효과 - 금개구리 서식처인 안터 저수지 생태공원 사례를 중심으로 -)

  • Byeon, Chan-Woo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.6
    • /
    • pp.145-159
    • /
    • 2010
  • A Sustainable Structured wetland Biotop (SSB) system was planned, designed, and finally constructed, and maintained in the An-teo Reservoir ecological park, which is the habitat of the endangered Gold-spotted Pond Frog. The system purifies polluted water of An-teo Reservoir which flows from up to bottom within the system. Water was sampled once a month at the inlet and at the outlet from December, 2009 to August, 2010. BOD5, SS, T-N and T-P were analyzed. Average influent and effluent BOD5 concentration was 2.9 and 1.0 mg/L, respectively, and BOD5 removal was 67%. SS concentration of influent and effluent averaged 18.1 mg/L and 2.5 mg/L, respectively, and SS abatement amounted to 86%. Average influent and effluent T-N concentration was 0.426 mg/L and 0.147 mg/L, respectively, and T-N retention was 66%. T-P concentration of influent and effluent averaged 0.071 mg/L and 0.022 mg/L, respectively, and T-P removal amounted to 68%. Plant and frog species of the system were monitored during the period. Amphibia and reptiles provided 7 species and 4 families including the Endangered Gold-Spotted Pond Frog (Rana chosenica ) which also lives in the system. Twenty-six plant species were naturally introduced into the system, however, they didn't make up a significant portion of the plant populations compared with the planted species. The endangered plants, Bladderwort (Utricularia vulgaris var. japonica ) and Euryale ferox were observed in An-teo Reservoir as well as in the system.

A Study on Improved Allocations of Permissible Water Pollution Load at the Implementing Stage of Tatal Water Pollution Load Management Plan (수질오염총량관리계획의 시행단계에서 오염부하량 할당방안 개선에 관한 연구)

  • Kim Sie-Heon;Rim Jay-Myung
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.51-56
    • /
    • 2005
  • Allocation of water pollution load from loading capacity can be much essential, controversial, and its standards can be applied case-by-case to the various situations. Allocation methods to point sources are generally 'Equal effluent concentration', 'Equal percent Treatment', Loading capacity at planning stage consists of basic pollution load, development pollution load, reserved pollution load and margin of safety. But at the implementing stage loading capacity can be consisted of allocatable load and margin of safety to give more flexibility in the total water pollution load management plan. In that case, we can re-adjust and altogether use the pollution load of point sources of series and non-point sources at the implementing stage.

Effect of Ozonation in Microfiltration Membrane for Wastewater Reuse (정밀여과법 하수재이용 공정에서 오존의 전처리 효과에 관한 연구)

  • Moon, Seong-Yong;Ahn, Se-Hyuk;Lee, Sang-Hyup;Park, Jong-Hoon;Hong, Suk-Won;Choi, Yong-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.535-543
    • /
    • 2006
  • The Ozone oxidation process was applied to increase the efficiency of reuse process when treating the secondary effluent by the membrane system. This paper focus on decreasing efficiency of membrane fouling, because of membrane fouling reduction by ozone and evaluation of application of the ozone oxidation. The feed water was secondary effluent from BNR process. The result shows that the ozone pretreatment can reduce membrane fouling effectively. Also, the improvement of treated water quality was obvious. The reduction of the membrane fouling led decrease of following pollutant and increase of lnner adsorptive ability of hydrophilic organic matter and decrease of molecular weight. MF membrane process alone can meet the domestic reuse water standards. And ozone pretreatment process also can increase the removal rates of turbidity, COD, nitrogen, and color.

Numerical Analysis of A Vortex Cyclone in A Recirculating Aquaculture System (순환여과 양식장에서 와류형 분리기에 대한 수치적 검토)

  • Jeong, S.K.;Kim, E.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.36-41
    • /
    • 2005
  • This study investigated the performance of a vortex hydrocyclone for solid removal in a recirculating aquaculture system. In a fish-breeding industry, effluent water is mainly disposed by gravity sedimentation. Thus, a large settling tank and a lot of water are needed to purify effluent water. However, this typical method does not show consistent efficiency. In case of low efficiency, discharged water contains a lot of feeding sediments. This causes environmental problems. Instead of this typical method a hydrocylone is tested to discharge water which contains a lot of feeding sediments. In this paper, a hydrocyclone with low velocity and pressure drop in a recirculating aquaculture system is investigated.

  • PDF

A Study on the Allocation of Permissible Water Pollution Load in the Total Water Pollution Load Management Plan (수질오염 총량관리계획과정의 오염부하량 할당에 관한 연구 - 경기도 광주시를 사례로 -)

  • Kim, Sie-Heon;Rim, Jay-Myung
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.337-346
    • /
    • 2005
  • Pollution load allocation can likely be much controversial, which is essential to formulate the total water pollution load management plan. Existing rules(or guidances) in Korea, can provide no specific criteria for load allocation. Therefore, this paper studied(comprehensively) possible standards how or why to choose any particular allocation method, which was applied in the Gwangju City's load allocation for the satisfaction of set water quality goal. This load allocation is basically focused on the load reduction of domestic wastewater rather than industrial wastewater, because the land-use is strictly regulated and larger sources of pollution are few in the Gwangju City. This paper recommends the city to increase the capacity of sewage treatment plants, promote sewerage maintenance, and set higher effluent standards.

Application of Micropaticle Systems in Water Circuit Closure Programs

  • Howard Johnson;Ha, Derek A.rrington
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.5
    • /
    • pp.12-20
    • /
    • 2001
  • The consequence of water system closure and reduced water consumption in Paper Mills is increased white-water conductivity associated with increased total dissolved solids. This leads to difficulties man-aging the wet end chemistry of paper machines, mainly due to stearic hindrance effects on wet end chemical additives. This in turn causes poor productivity and Inefficient chemicals usage. The success of a number of projects is reported. The application and development of new multi-component micro-particle systems which can further assist in achieving a significant degree of system closure or Zero Effluent is described.

  • PDF

Review of the Agricultural Water Quality Standards through Rice Culture with Treated Sewage Irrigation (오수처리수 관개 벼재배를 통한 농업용수 수질기준의 검토)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.2
    • /
    • pp.44-54
    • /
    • 1999
  • Agricultural water quality standards were reviewed through rice culture using treated sewage irrigation . The seqage from school building of Konkuk University was treated by a constructed wetland system, and theeffluent of the systeml was irrigated for rice culutre after nutrient concentration adjusted by dilution. Average concentration of COD, SS, T-N and T-P in irrigated water was 22.3mg/$\ell$, 6.5mg/$\ell$, 25.8 mg/$\ell$and 2.2mg/$\ell$, respectively. Treatment include irrigation of adjusted effluent with conventional fertilization (TWCF), adjusted effluent with no fertilization (TWNF). and effluent of the wetland system as it was with no fertilization (SWNF). These treatment plots were compared with control plot irrigated by tap water with conventional fertilization (CONTROL). Other environmentals for rice culture were identical for all the plots. Among them, TWCF showed the best growth rate and the highest yield, and constituents in the harvested rice showed not much difference among them. Which implies that irrigation with relatively high nutrient concentration compared to the current water quality standards may cause no adverse effect on rice culture and could be even beneficial . Although T-N for this study was 25 times greater than the current standards, rice culture wasnot adversely affected by irrigatino water quality and even beeter results were observed than the CONTROL. It could be mistakenly that clean irrigation water produces better agricultural product, however, it is not necessarily true. Irrigation water with moderate nutrient concentration can enhance the plant growth, and better result might be expected. Therefore, peer review and modification if necessary are needed to the current agricultural water quality standards, especially for the nutrient components.

  • PDF