Spread Patterns of Thermal Effluent Discharged From Young-Kwang Nuclear Power Plant Using Remote Sensing Data

  • Han J. G.;Yeon Y. K.;Chi K. H.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.331-335
    • /
    • 2004
  • This study is focused to analyze the movement of thermal effluent dischargeed from nuclear power plant by season, ebb and flow, and before and after foundation of tide embankment using thermal infrared band image of 28 scenes observed from Landsat from 1987 to 2004, which is the early stage of operation of young-kwang nuclear power plant. In diffusion of thermal effluent discharge by seasons, spring and summer is spreading further than autumn and winter. It is considered to distribute widely mixed with thermal effluent discharge and hot water, which is distributed naturally along the seaside. It is known the fact that tidal currents control the direction of diffusion of thermal effluent discharge by the change of ebb and flow. Namely, it is distributed widely on the Southwest direction along the seaside by tidal currents when ebb and, it is moved widely on the Northeast direction along the seaside by tidal current when flood. However, in the early stage of flood current, the mainstream of thermal effluent discharge is spread on Southwest direction and, the direction is changed on North­east way when the latter period of flood current. Similarly, in the early stage of ebb current, the mainstream of thermal effluent discharge is spread on Northeast direction and, the direction is changed on Southwest direction when the latter period of ebb current. As the result of comparing to the diffusion pattern of thermal effluent discharge before and after the foundation of seawall, discharged thermal effluent from the drain of plant by the foundation of dike is shown as curved circle pattern on Northeast to West direction from the ending portion of the seawall.

  • PDF

Characteristics on the decomposition of BDOC in the BAC tower (BAC탑(塔)에서의 BDOC 분해특성(分解特性))

  • Kim, Dong-Youn;Lee, Sang-Bong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.21-29
    • /
    • 1998
  • The ozone/GAC process, sometimes termed BAC(Biological Activated Carbon) appeared to be effective for the removal of soluble organic matters in the drinking water Chabrol is a simple model for the simulation like as the variation of HPC and BDOC in the BAC tower. This study were carried out to calibrate of HPC and BDOC and to evaluate $H_1$ and $H_2$ of ozone-treated water with Chabrol model. BDOC values of the ozone-treated water and BAC effluent are analyzed using method of Levi and Joret. As the ozone-treated water and BAC Effluent are incubated, the HPC are increased up to 0.24 mgC/l and 0.09 mgC/l respectively. $H_1$ and $H_2$ of the ozone-treated water is 0.3 mgC/l and 0.349 mgC/l respectively and Chabrol model for BAC tower can be calibrated.

  • PDF

Assessment of Leachate from Solid Waste Landfills in Daechong Lake Upper Drainage Basin (대청호 상류유역 매립지의 침출수 분석 및 평가)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.3
    • /
    • pp.161-170
    • /
    • 2003
  • To investigate the characteristics of 17 solid waste landfills in the upper drainage basin of Lake Daechong, the landfill sites were surveyed, the leachate of these landfills were analyzed, and the analysis results were assessed from standpoint of water contamination. Sanitary landfills which are now being operated are relatively well equipped with facilities such as leachate collection, daily soil cover and landfill gas treatment devices. But a few of open-dumping landfills were leaking leachate apparently and were supervised improperly and neglectfully by local governments. Some of sanitary landfills exceeded the COD permission criteria of leachate effluent, and some of open-dumping landfills exceeded SS, T-P, Pb, As, Fe, Mn permission criteria of leachate effluent. To improve the water quality of Lake Daechong which is utilized for supplying drinking water, agricultural water, and industrial water to the great part of Chungchong area, the adequate and prompt measures for preventing Daechong Lake water contamination from landfills leachate is necessary.

Manganese Removal of Bank Filtrate using Manganese Sand Filtration (망간모래여과를 이용한 강변여과수의 망간제거)

  • Kim, Chung-Hwan;Kim, Hak-Chul;Kim, Han-Seung;Kim, Berm-Soo;Ahn, Hyo-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.409-414
    • /
    • 2004
  • Pilot-scale experiments were performed for the treatment of bank filtrate contammg high manganese concentration around 2mg/L using rapid manganese sand filtration to investigate effects of oxidant dose and pH control on the removal efficiency of manganese. For theoretical dose ranges of oxidant (sodium hypochlorite) between 3 and 4mg/L, the manganese concentration of effluent was 0.57 mg/L, which corresponded to 72.5% removal and was higher than drinking water quality standards of 0.3mg/L. For excess dose ranges of oxidant between 4 and 8mg/L, the manganese concentration of effluent was reduced to 0.14mg/L, which corresponded to 94.5% removal, but the residual chlorine concentration was over 1.0mg/L. On the other hand, manganese removal efficiency drastically increased up to the value of 98.0%, which is equivalent to the effluent concentration of 0.03mg/L by controling pH to the range between 7 and 8 for the theoretical dose of oxidant. Consequently, these results indicated that appropriate dose of chemicals, such as oxidant and alkali, and continuous monitoring of manganese should be necessary to obtain efficient removal of manganese and to optimize the maintenance of treatment facilities for the treatment of bank filtrate with high concentration of manganese.

Cycle Simulation on OTEC System using the Condenser Effluent from Nuclear Power Plant (원자력발전소 온배수를 이용한 해양 온도차발전 사이클 해석)

  • Kim, Nam-Jin;Jeon, Young-Han;Kim, Chong-Bo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.37-44
    • /
    • 2007
  • For the past few years, the concern for clean energy has been greatly increased. Ocean Thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this paper, the thermodynamic performance of OTEC cycle was examined. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regeneration cycle, Kalina cycle, open cycle and hybrid cycle. The results show that the regeneration cycle using R125 showed a 0.17 to 1.56% increase in energy efficiency, and simple Rankine cycle can generate electricity when the difference in warm and cold sea water inlet temperatures are greater than $15^{\circ}C$. Also, the cycle efficiency of OTEC power plant using the condenser effluent from nuclear power plant instead of the surface water increased about 2%.

The Limiting Nutrient of Eutrophication in Reservoirs of Korea and the Suggestion of a Reinforced Phosphorus Standard for Sewage Treatment Effluent (국내 호수의 제한영양소와 하수처리장 방류수 인 기준 강화의 필요성)

  • Kim, Bomchul;Sa, Seung-Hwan;Kim, Moonsook;Lee, Yunkyoung;Kim, Jai-Ku
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.512-517
    • /
    • 2007
  • The limiting nutrient of eutrophication in freshwater bodies in Korea was examined and the phosphorus concentration standard for sewage treatment effluent was discussed. The weight ratio of N/P in 13 major reservoirs showed the range of 18 to 163, which implies phosphorus is more limited than nitrogen for algal growth. In the correlation analysis phosphorus showed higher correlation with chlorophyll-a concentration than with nitrogen. In the algal bioassay phosphorus spike test enhanced algal growth in all 25 samples of five reservoirs, while nitrogen was found to co-limit only in four samples. It confirms that phosphorus is the only limiting nutrient for eutrophication in Korean reservoirs. As many reservoirs are eutrophic in Korea, phosphorus control is critical for the management of water quality. The phosphorus standard of sewage treatment effluent in Korea was compared with other countries, and it can be concluded that phosphorus standard is too high to be effective in eutrophication control and a lower phosphorus standard is essential for the water quality improvement.

Sludge Thickening using Electro-Flotation in Water Treatment Plant (전해부상에 의한 상수 슬러지 농축효율)

  • Lee, Jun;Han, Mooyoung;Dockko, Seok;Park, Yonghyo;Kim, Tschungil;Kim, Mikyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Gravity thickening process has been widely used in WTP sludge thickening at domestic water treatment plant. The operation method of the process is very simple, however, the process requires long detention time about 24~48 hours for sludge thickening, uses polymer, and low total solids of thickened sludge to increase sludge thickening efficiency. To solve there problems, we studied about flotation process, especially, electro-flotation (EF) process in WTP sludge thickening. Electro-flotation process is simpler than dissolved-air-flotation(DAF) process because EF needs only electrode and current to generate micro-bubbles and the operation is easy. This study was performed at two batch columns to compare interface height, total solids, effluent turbidity between an electro-flotation thickening and a gravity thickening. According to the result, an electro-flotation thickening was that interface height was decreasing, total solids had high concentration, and effluent turbidity was low in comparison with a gravity thickening. Also, it will make the high efficiency of following process, such as a dehydrating process and digestive process. because of high total solids and low moisture content in the sludge.

Contributions of emergent vegetation acting as a substrate for biofilms in a free water surface constructed wetland

  • Zhao, Ruijun;Cheng, Jing;Yuan, Qingke;Chen, Yaoping;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • This study assessed the contribution of emergent vegetation (Phragmites australis, Typha latifolia, and Nelumbo nucifera) to the submerged surface area, the amount of biofilms attached to the submerged portions of the plants, and the treatment performance of a free water surface (FWS) constructed wetland. Results showed that a 1% increase ($31m^2$) in the vegetative area resulted in an increase of $220m^2$ of submerged surface area, and 0.48 kg Volatile Suspended Solids (VSS) of attached biofilm. As the vegetation coverage increased, effluent organic matter and total Kjeldahl nitrogen decreased. Conversely, a higher nitrate concentration was found in the effluent as a result of increased nitrification and incomplete denitrification, which was limited by the availability of a carbon source. In addition, a larger vegetation coverage resulted in a higher phosphorus in the effluent, most likely released from senescent biofilms and sediments, which resulted from the partial suppression of algal growth. Based on the results, it was recommended that constructed wetlands should be operated with a vegetation coverage of just under 50% to maximize pollutant removal.

Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System (DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구)

  • Lee, Byoung Ho;Kim, Sang Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

Effect of Hydrogen Peroxide on UV Treatment of Color in Secondary Effluent for Reclamation (물 재이용을 위한 하수처리장 방류수 색도의 자외선처리에 미치는 과산화수소의 영향)

  • Park, Ki-Young;Maeng, Sung-Kyu;Kim, Ki-Pal;Lee, Seock-Heon;Kweon, Ji-Hyang;Ahn, Kyu-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.377-384
    • /
    • 2004
  • In the present study, a feasibility of an advanced oxidation process using UV/Hydrogen peroxide($H_2O_2$) system equipped with a medium pressure lamp for secondary effluent reclamation was investigated. Initial concentration of $H_2O_2$ and pH were changed to determine the optimum operation condition for the system. The removal efficiency of color was than 80% with 14.3mg/L of initial $H_2O_2$ and 5 minute of contact time in the UV/$H_2O_2$ system. The color removal was analyzed using first-order reaction equation. The dependence of rate constant (k) on initial $H_2O_2$ represented the rational relationship with maximum value. Residual $H_2O_2$ caused increase of effluent COD, since analyzing agent, dichromate, reacted with $H_2O_2$ in the sample. Therefore, excess initial concentration of $H_2O_2$ would significantly affect effluent COD measurement. At pH variation experiment, both residual $H_2O_2$ and color showed peak in the neutral pH range with the same pattern. Effect of $H_2O_2$ dose also enhanced color removal but raised residual $H_2O_2$ problem in the continuous operation UV system. In conclusion, these results indicated that medium pressure UV/$H_2O_2$ system could be used to control color in the secondary effluent for reclamation and reuse.