• 제목/요약/키워드: effluent flow

검색결과 287건 처리시간 0.021초

하천수를 정화하는 수평흐름 여과습지의 표면 잔재물층 유무에 의한 질소제거 비교 (Comparison of Nitrogen Removal in a Horizontal Subsurface-Flow Wetland Purifying Stream Water with and without Litter Layer on its Surface)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제12권1호
    • /
    • pp.111-122
    • /
    • 2009
  • Abatements of TN and ${NO_3}^-$-N in a horizontal subsurface-flow wetland with litter layer on its surface were compared with those without one. The wetland was constructed in 2001 on floodplain of the Gwangju Stream which flows through Gwangju City in Korea. Its dimensions were 29m in length, 9m in width and 0.65m in depth. A bottom layer of 45cm was filled with crushed granites (15~40mm in diameter) and a middle layer of 10cm had pea pebbles. An upper layer of 5cm contained coarse sands. Reeds (Phragmites australis) growing in natural wetlands were transplanted on its surface. Water of the stream was channelled into the wetland by gravity flow and its effluent was discharged back into the stream. Average Litter layer of 12.2cm was formed on its surface in 2007. The layer and above-ground parts of reeds were eliminated in April 2008. Volumes and water quality of influent and effluent of the wetland were analyzed from May to November in 2007 and 2008, respectively. Inflow into the wetland both in 2007 and 2008 averaged approximately 40$m^3$/day and hydraulic residence time both in 2007 and 2008 was about 1.5days. Influent TN concentration in 2007 and 2008 averaged 3.96 and 3.89mg/L, respectively and average influent ${NO_3}^-$-N concentration in 2007 and 2008 was 2.11 and 2.05mg/L, respectively. With a 0.05 significance level, influent concentrations of TN and ${NO_3}^-$-N, temperatures and pH of effluent, and heights and stem numbers of reeds showed no difference between the wetland with litter layer and without one. TN retention in the wetland with litter layer and without one averaged 64,76 and 54.69%, respectively and ${NO_3}^-$-N removal averaged 60.83 and 50.61%, respectively. Both TN and ${NO_3}^-$-N abatement rates in the wetland with litter layer were significantly high (TN abatement: p<0,001, ${NO_3}^-$-N abatement: p=0.001) when compared with those without one. The subsurface-flow wetland having litter layer on its surface was more efficient for TN and ${NO_3}^-$-N removal.

인공신경망 및 물질수지 모델을 활용한 하수처리 프로세스 시뮬레이터 구축 (Development of Wastewater Treatment Process Simulators Based on Artificial Neural Network and Mass Balance Models)

  • 김정률;이재현;오재일
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.427-436
    • /
    • 2015
  • Developing two process models to simulate wastewater treatment process is needed to draw a comparison between measured BOD data and estimated process model data: a mathematical model based on the process mass-balance and an ANN (artificial neural network) model. Those two types of simulator can fit well in terms of effluent BOD data, which models are formulated based on the distinctive five parameters: influent flow rate, effluent flow rate, influent BOD concentration, biomass concentration, and returned sludge percentage. The structuralized mass-balance model and ANN modeI with seasonal periods can estimate data set more precisely, and changing optimization algorithm for the penalty could be a useful option to tune up the process behavior estimations. An complex model such as ANN model coupled with mass-balance equation will be required to simulate process dynamics more accurately.

Comparison of CDI and MCDI applied with sulfonated and aminated polysulfone polymers

  • Kim, Ji Sun;Rhim, Ji Won
    • Membrane and Water Treatment
    • /
    • 제7권1호
    • /
    • pp.39-53
    • /
    • 2016
  • In this study, polysufone (PSf) was used as a base polymer to synthesize sulfonated polysulfone (SPSf) and aminated polysulfone (APSf) as cation and anion exchange polymers, respectively. Then the ion exchange polymers were coated onto the surface of commercial carbon electrodes. To compare the capacitive deionization (CDI) and membrane capacitive deionization (MCDI) processes, the pristine carbon electrodes and ionic polymer coated electrodes were tested under various operating conditions such as feed flow rate, adsorption time at fixed desorption time, and feed concentration, etc., in terms of effluent concentration and salt removal efficiency. The MCDI was confirmed to be superior to the CDI process. The performance of MCDI was 2-3 times higher than that of CDI. In particular, the reverse desorption potential was a lot better than zero potential. Typically, the salt removal efficiency 100% for 100 mg/L NaCl was obtained for MCDI at feed flow rate of 15 ml/min and adsorption/desorption time of 3 min/1 min and applied voltages 1.0 V for adsorption and -0.3 V for desorption process, and for 500 mg/L, the salt removal efficiency 91% was observed.

간척지 논 농업배수 처리에 적합한 인공습지 설계 기법 (Constructed Wetland Design Method to Treat Agricultural Drainage from Tidal Reclaimed Paddy Areas)

  • 장정렬;신유리;정지연;최강원
    • 한국관개배수논문집
    • /
    • 제18권1호
    • /
    • pp.4-17
    • /
    • 2011
  • The standard design methodology was suggested to construct wetland system for reducing non-point source pollution from Saemangeum reclaimed paddy land. To set for the design flow and concentrations, runoff and water quality survey were conducted during the irrigation period in 2008 at Gyehwa reclaimed paddy land located at near Saemangeum lake. It is rational that 1ha is the optimum constructed wetland size. To meet this size, the moderate drainage area of reclaimed paddy field was 50ha under the conditions that rainfall is 30mm, average runoff coefficient is 0.83, and runoff capture ratio is 0.6. At these condition, the runoff volume from 50ha was 10,520 $m^3/d$ including base flow during irrigation period. To select the optimum wetland system, several case studies were conducted by focusing on the tidal reclaimed land areas having wetland systems in Seokmun. Pond-Wetland system was selected as the standard model because of showing the highest reduction efficiency. Single variable regression equation were delivered to estimate effluent water concentrations from the designed wetland by using long-term monitoring data from the Seokmun experiment site. The effluent concentration from the designed wetland using these equation were showed moderately range.

  • PDF

Comparing geometric parameters of a hydrodynamic cavitation process treating pesticide effluent

  • Randhavane, Shrikant B.
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.318-323
    • /
    • 2019
  • Paper focuses on comparison between two different orifice plate configurations (plate number 1 and plate number 2) used as cavitating device in the hydrodynamic cavitation reactor for improving pollutant removal efficiencies. Effect of four different parameters such as hydraulic characteristics (in terms of range of flow rates, orifice velocities, cavitation number at different inlet pressures); cavitation number (in range of 5.76-0.35 for plate number 1 and 1.20-0.35 for plate number 2); inlet pressure (2-8 bars) and reaction time (0 to 60 min) in terms of chemical oxygen demand (COD) removal and chlorpyrifos degradation has been studied and compared. Optimum inlet pressure of 5 bars exists for degradation of pollutants for both the plates. It is found that geometry of orifice plate plays important role in removal efficiencies of pollutant. Results obtained confirmed that orifice plate 1 with configuration of 1.5 mm 17 holes; cavitational number of 1.54 performed better with around 60% COD and 98% chlorpyrifos removal as compared to orifice plate 2 having configuration of 2 mm single hole; cavitational number of 0.53 with 40% COD and 96% chlorpyrifos in 2 h duration time.

낙동강 수계 하.폐수 처리시설의 방류수가 조류 성장 잠재력에 미치는 영향 (Effect of the Sewage and Wastewater Plant Effluent on the Algal Growth Potential in the Nakdong River Basin)

  • 서정관;이재정;양상용;정익교
    • ALGAE
    • /
    • 제18권2호
    • /
    • pp.157-167
    • /
    • 2003
  • Effect of the effluent of the sewage and wastewater plants on the algal growth was investigated from the 19 plants located in the Nakdong river basin. Most of the samples showed high values of the algal growth potential (AGP) when they were mixed with natural river water at 20% of final concentration. At 20% of the mixing ratio, the mixed effluents of sewage and wastewater showed 3.5 and 1.8 times higher AGP than those of the natural river water. The higher AGP values are attributable to the high contents of phosphorus and ammonium in the effluent. The mixing ratio of effluents of the discharge/river flow was highest in the Kumho River (42.8%) followed by the middle of Nakdong River (22.7%), Kam Stream (13.9%), Byungsung Stream (13.3%), Yangsan Stream (7.9%), and Young River (5.4%). Comparison of the trophic state of the effluents with natural river water indicated that the effluents showed higher trophic values than natural water. Concentrations of total phosphorus, total nitrogen and conductivity in the effluents were 12.3, 4.9 and 5.3 times higher than the those found in natural river water respectively. The AGP values were highly related with the trophicity of the water especially on the concentrations of phosphate and ammonium. Toxicities of the treated sewage water, wastewater and livestock waste water tested by the luminescent bacteria, Vibrio fischerii were generally low.

속초 해양방류 하.폐수의 혼합구역에 대한 특성분석 (Mixing Zone Analysis of Wastewater Effluent Discharged from Sokcho Ocean Outfall)

  • 강시환;박연숙;김상익;이호진
    • 한국해안해양공학회지
    • /
    • 제13권3호
    • /
    • pp.245-253
    • /
    • 2001
  • 속초 하수종말처리장에서의 하·폐수 해양방류에 따른 혼합구역 특성을 파악하기 위해 Huang et al.(1996)의 분석방법을 활용하여 혼합구역 모형을 수립하였다. 겨울철인 11월 하순부터 1월까지 약 2개월 동안 속초 해양방류수역에서 매시간 연속 관측된 해류, 해수 밀도의 성층자료, 그리고 하수 방류량자료를 입력한 모형모의를 통해 속초 해양방류수역에서 하수농도의 분포변화를 계산하였으며, 동일 기간에 관측된 조석자료를 토대로 약 15일 간격으로 구분한 기간 동안에 대해 평균한 농도분포를 제시하였다. 이 결과에 의하면 겨울철동안 평균된 최소희석률은 130으로 방류 하수의 혼합·의석이 대체로 양호했다. 그러나 해안에 평행한 연안류와 조류의 주 방향에 따라 방류하수의 혼합구역이 외해보다는 해변 쪽으로 확장되고 있어 인근 해수욕장의 수질악화에 큰 영향을 미칠 것으로 판단된다.

  • PDF

공공하수처리시설 수질기준 선진화 방안 (Improvement on Sewerage Effluent Standard of Public Sewerage Treatment Plants)

  • 유순주;박상민;권오상;박수정;염익태
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.276-287
    • /
    • 2013
  • Domestic sewage contains increasingly more pharmaceuticals and personal care products (PPCPs), due to rising use of medicines, health supplement food and daily necessities. And various types of industrial wastewater from pollution sources in treatment areas could flow into the public sewerage treatment plants (PSTPs) in metropolitan areas. The conventional PSTPs are designed to treat suspended solids, biodegradable organics, nitrogen and phosphorous from residential and industrial areas and public facilities. However, toxic, conventional, and non-coventional pollutants from non-domestic sources that discharge into sewer system as well as domestic source with various chemicals could not be treated in the conventional PSTPs and discharged untreated to public basin. In this paper we aim to consider the establishment system of effluent standard of PSTPs in comparison with water quality standard of water environment and wastewater discharge regulation. And also we suggest the necessity of regulations on the pretreatment of industrial wastewater as part of efforts to improve water quality in sewerage systems and to protect public basin.

처리기술 수준에 근거한 배출허용기준 설정을 위한 BAT 도입 연구 (Assessment of the Best Available Technology to Establish the Industrial Wastewater Effluent Limitations Guidelines)

  • 임병진;권오상;김영노
    • 생태와환경
    • /
    • 제38권3호통권113호
    • /
    • pp.281-288
    • /
    • 2005
  • 폐수배출시설별 BAT 평가제도는 폐수특성을 고려한 배출시설별 배출허용기준 설정, 오염총량관리기본계획 및 시행계획에 따른 오염부하삭감 가능량 산정, 신규오염물질에 대한 배출허용기준 산정 등 효율적인 산업폐수관리를 위해서 도입할 필요가 있다. 본 연구에서는 외국사례와 국내 폐수배출시설들의 현황 등을 조사하여 국내여건에 적합한 BAT 평가방안을 제시하였다. 본 평가절차의 핵심은 폐수배출시설별 처리시설에 대한 환경인자, 경제적 수용가능성, 기술적 인자 및 경제성 등을 객관성 있고 전문적인 판단이 가능토록 한데 있다. 본 BAT 평가방안은 처리수준에 근거한 폐수배출시설별 배출허용기준마련 및 오염총량관리를 위한 기초 자료로 활용할 수 있으며, 신규오염물질 및 유해오염물질의 배출허용기준 마련 등 정책적${\cdot}$법적 제도개선에 유용하게 활용할 수 있을 것으로 사료된다.

강원 영서지역 하수처리장이 수질에 미치는 영향 (Effect of Municipal Sewage Treatment Plant on Water Quality in Western Kangwon Area)

  • 허인량;최지용;김영진;정의호
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.235-240
    • /
    • 2005
  • The effects of municipal sewage treatment plants on the water quality and effluent loading were investigated. BOD removal rates from Wonju, Hoengseong, and Hongcheon municipal sewage treatment plants were $88.9\%,\;80.6\%,\;90.7\%$ and T-P removal rates were $47.3\%,\;56.5\%,\;71.6\%,$ respectively. Also, BOD effluent leading from WonJu, Hoengseong, and Hongcheon treatment plants were 1,520 kg/day, 75 kg/day, 55 kg/day and T-P effluent loading were 203.9 kg/day, 4.2 kg/day, 4.0 kg/day, respectively. In terms of water quality distribution by distance of flow, BOD of the Seom river rapidly rose from 1.6 mg/l to 4.0 mg/l and T-P rose from 0.034 mg/l to 0.321 mg/l. Also BOD of the Hongcheon river showed a slowly rise from 1.1 mg/l to 1.4 mg/l and T-P from 0.011 mg/l to 0.026 mg/l. In conclusion, the effects of municipal sewage treatment plants on the water quality proved that T-P was higher than BOD. Consequently, in order to improve water quality, it is necessary to adopt an advanced sewage treatment system like nutrient removal.