• Title/Summary/Keyword: efficiency test

Search Result 5,982, Processing Time 0.037 seconds

An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes (내부유공판을 사용한 각형 CFT 기둥-보 단순인장 접합부의 실험적 연구)

  • Lee, Seong Hui;Jung, Hun Mo;Yang, Il Seung;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.575-583
    • /
    • 2009
  • As the height of buildings rises, new structural systems are being applied other than theexisting S, RC, and SRC to decrease the weight of buildings and to make their construction more efficient, CFT structureshad been applied in many building construction projects due to their superior structural performance and construction efficiency. CFT structures need a diaphragm to harmoniously transmit the beam flange load to the column and the opponent beam in connections. Especially, on the right and left sides of the column other beams are connected, The establishment of a diaphragm for the lower part flange load delivery of the beam and guarantee for concrete filing capacity difficulty have (What does this mean?). In this paper, connection details are proposed in the form of a welded vertical plate with a circular hole on the CFT column's interior to harmoniously transmit the lower-part beam flange load to the column and the opponent beam. Thesediaphragm details use the concrete anchor effect in the beam flange load delivery, with the concrete-filled CFT column interior piercing the hole of the perforated plate, and a perforated board is established vertically to improve the concrete filling capacity. To analyze the structural performance of the proposed connection details, five simple tension specimens were made with the following parameters: with our without vertical and horizontal perforated plates, shear hole number, concrete filled or not, thickness of the perforated plate, etc. Then experimental tests were performed on these specimens.

Comparison of Compliance, Time Required for Diagnosis and Pain of Patients with Finger Tendon Injury Between Gross and Ultrasonographic Confirmation (손가락 힘줄 손상환자에서 육안 검사와 초음파 검사의 순응도, 시간, 통증의 비교)

  • Lee, Seo-Woo;Park, Hyun-Jae;Lee, Jung-Won;Park, Sae-Hoon;Kim, Jae-Woo
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.83-88
    • /
    • 2010
  • Purpose: It is not always easy to determine the existence of tendon injuries when it comes to patients with finger lacerations. Thus, we tried to find the difference in effectiveness and in compliance of patients when we employed two different types of diagnosis, conventional gross confirmation and ultrasonographic confirmation. Methods: From December 2009 to March 2010, we enrolled 14 patients with finger tendon injury at Soonchunhyang University Cheonan Hospital. The median age of the patients was $35.9{\pm}14.4$, and the ratio of females to males was 1:2.5 We evaluated the compliance of each patient by measuring four different categories (level of cooperativeness in showing their wound and in following the instructions, level of movement of their fingers during the diagnosis and total number of attempts to diagnose) by using a score from 1 to 3 for each category, for a total possible score of 12 for each patient. We also measured the painfulness of each patient by using a score of 1 to 10 and the time required for each diagnosis. Results: The levels of patients' compliance was $8.9{\pm}2.1$ when diagnosed with gross confirmation and $9.8{\pm}2.1$ when diagnosed with ultrasonographic confirmation (p value=0.042). The pain score of the patients was $3.7{\pm}1.7$ with gross confirmation and $2.9{\pm}1.2$ with ultrasonographic confirmation (p value=0.020). The median duration of time in each test was $6.7{\pm}4.8$ minutes with gross confirmation and $10.5{\pm}4.2$ minutes with ultrasonography (p value=0.006). Conclusion: Comparing gross confirmation and ultrasonographic confirmation, gross confirmation is a better method than ultrasonography because of time efficiency. However, ultrasonographic confirmation has advantages over gross confirmation in pain scale and better compliance of patients. Emergency physicians generally employ gross confirmation rather than ultrasonography in determining the existence of tendon injury in patients. In patients with finger lacerations without bone injury, ultrasonography can be considered as a secondary diagnostic tool, especially when patients have much pain.

Development of the New Hybrid Evolutionary Algorithm for Low Vibration of Ship Structures (선박 구조물의 저진동 설계를 위한 새로운 조합 유전 알고리듬 개발)

  • Kong, Young-Mo;Choi, Su-Hyun;Song, Jin-Dae;Yang, Bo-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.164-170
    • /
    • 2006
  • This paper proposes a RSM-based hybrid evolutionary algorithm (RHEA) which combines the merits of the popular programs such as genetic algorithm (GA), tabu search method, response surface methodology (RSM). This algorithm, for improving the convergent speed that is thought to be the demerit of genetic algorithm, uses response surface methodology and simplex method. The mutation of GA offers random variety to finding the optimum solution. In this study, however, systematic variety can be secured through the use of tabu list. Efficiency of this method has been proven by applying traditional test functions and comparing the results to GA. And it was also proved that the newly suggested algorithm is very effective to find the global optimum solution to minimize the weight for avoiding the resonance of fresh water tank that is placed in the rear of ship. According to the study, GA's convergent speed in initial stages is improved by using RSM method. An optimized solution is calculated without the evaluation of additional actual objective function. In a summary, it is concluded that RHEA is a very powerful global optimization algorithm from the view point of convergent speed and global search ability.

  • PDF

A Study on Automatic Threshold Selection in Line Simplification for Pedestrian Road Network Using Road Attribute Data (보행자용 도로망 선형단순화를 위한 도로속성정보 기반 임계값 자동 선정 연구)

  • Park, Bumsub;Yang, Sungchul;Yu, Kiyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Recently, importance of pedestrian road network is getting emphasized as it is possible to provide mobile device users with both route guidance services and surrounding spatial information. However, it costs a tremendous amount of budget for generating and renovating pedestrian road network nationally, which hinder further advances of these services. Hence, algorithms extracting pedestrian road network automatically based on raster data are needed. On the other hand, road dataset generated from raster data usually has unnecessary vertices which lead to maintenance disutility such as excessive turns and increase in data memory. Therefore, this study proposed a method of selecting a proper threshold automatically for separate road entity using not only Douglas-Peucker algorithm but also road attribute data of digital map in order to remove redundant vertices, which maximizes line simplification efficiency and minimizes distortion of shape of roads simultaneously. As a result of the test, proposed method was suitable for automatic line simplification in terms of reduction ratio of vertices and accuracy of position.

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

Treatment of High Organic Wastewater Using Ecological Water Treatment System (생태학적 수처리 시스템을 이용한 고농도 유기성 폐수처리)

  • 조재훈;김중곤;김준휘;윤성명;이정섭;김시욱
    • Korean Journal of Microbiology
    • /
    • v.37 no.4
    • /
    • pp.317-324
    • /
    • 2001
  • We have previously developed three stage methane fermentation system capable of digesting food wastes effectively and then releasing high organic wastewater as a final product. In this study, we tried to devise an ecological water treatment system, which can efficiently remove the nitrogen and phosphorus contained in the organic wastewater. The system was made of microbiological filters, algae, and waterfleas. Of two species of alga tested, Selenastrum capricornutum showed higher growth rate and more efficiently removed the nitrogen from the wastewater than by Chlorella sp. In addition, the highest growth rate and the nitrogen removal efficiency could be obtained when high concentrations of $Mg^{2+}\; and\; Ca^{2+}$ were added to the diluted wastewater and the molar ratio of nitrogen to phosphorus was adjusted to 10 : 1. In this study the population relationship between alga and water flea was also examined in a test tube. The initial number of algal cells decreased as the waterflea population increased. However, the number of algal cells gradually increased again when waterflea population decreased partly due to the environmental resistance. From these results, it was believed that the ecological water treatment system could be used for removing the nitrogen and phosphorus from organic wastewater very effectively. Moreover, the waterflea cultured by this system as a final predator could be used as a good foodstuff for fishes.

  • PDF

Detection of Microbial Growth in an Automated Culture System (자동배양기를 이용한 미생물 검출)

  • Sung, Hye-Ran;Kim, Il-Hoi;Kim, Jee-Youn;Lee, Chong-Kil;Chung, Yeon-Bok;Han, Sang-Bae;Song, Suk-Gil
    • Korean Journal of Microbiology
    • /
    • v.44 no.2
    • /
    • pp.130-134
    • /
    • 2008
  • Modern automated culture systems have increased the isolation rate of microorganisms and shortened the time to detection, reducing experimental errors in diagnosis of infecting agents. BacT/ALERT 3D system is based on the colorimetric detection of $CO_2$ produced by the growing microorganisms. In order to evaluate the efficiency of the detection system, sterility test were performed using 6 bacteria. With standard aerobic and anaerobic bottles containing the liquid media, both three aerobic bacteria (P. aeruginosa, M. luteus, B. subtilis) and a facultative bacterium S. aureus were detected up to 1 CFU in 31.44 hr. In addition, growth of anaerobic C. sporogenes was recognized up to 1 CFU in 15.96 hr. The slowly growing bacteria P. acnes was detected up to 10,000 CFU in 129.36 hr. In comparison with conventional culture method, BacT/ALERT 3D automated culture system was more sensitive and saved detection time up to$2\sim10$ hr. Therefore, this automated culture system enables to efficiently detect bacteria in clinical samples and biological medicines.

Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber (소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가)

  • Lee, Suk-Jo;Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.344-354
    • /
    • 2005
  • This study was carried out to evaluate the performance of a small chamber sampling and analytical method for the measurement of total volatile organic compounds (TVOC) and formaldehyde (HCHO) emission from building materials. While VOC was determined by the adsorbent tube sampling and sequential thermal desorption coupled with GC/MSD analysis, formaldehyde sampled with DNPH-silica cartridge was analyzed by HPLC. Wide-range performance criteria such as repeatability, desorption efficiency, emission chamber recovery test, duplicate precision, breakthrough volume and method detection limits were investigated for the evaluation of small chamber method. The overall precision of the small chamber sampling and analytical methods was estimated within 20~30% for target compounds. In conclusion, this study demonstrated that the small chamber sampling and analytical method can be reliably applied for the measurement of building materials pollutants.

Process Analysis on the Decontamination of Internal Surface of $UF_6$ Cylinder ($UF_6$ 실린더 내부표면 제염에 관한 공정분석)

  • Chun, Kwan-Sik;Yoo, Sung-Hyun;Cho, Young-June;Hong, Jang-Pyo;Han, Wook-Jin;Choi, Beong-Soon;Kang, Pil-Sang;Cho, Suk-Ju
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.3
    • /
    • pp.161-165
    • /
    • 2009
  • To evaluate the efficiency of the decontamination plant for the removal of uranium compounds deposited on the internal surface of $UF_6$ cylinder for its reuse, two demonstration tests of the plant with different ratio of ${Na_2}{CO_3}$ and ${H_2}{O_2}$ were carried out, and each test had 5 steps. The main chemical form removed by the tests was to be identified as ${Na_4}{UO_2}(CO_3)_3$. More than 50% of uranium was removed by water of the first step, and at the following steps the removal amounts were exponentially decreased. On the other hand, the result shows that the injected amount of ${Na_2}{CO_3}$, compared with that of the removed uranium, was stoichiometrically excessed. This suggests that the injected amounts of ${Na_2}{CO_3}$, the generation rate of decontaminated waste, and the decontamination steps could be reduced by a process optimization of the plant.

  • PDF

Spatial-temporal Variations of Nitrate Levels in Groundwater of Jeju Island, Korea: Evaluation of Long-term (1993-2015) Monitoring Data (제주도 지하수질산염 농도의 시·공간적변화 특성: 장기(1993-2015) 모니터링 자료의 평가)

  • Kim, Ho-Rim;Oh, Junseop;Do, Hyun-Kwon;Lee, Kyung-Jin;Hyun, Ik-Hyun;Oh, Sang-Sil;Kam, Sang-Kyu;Yun, Seong-Taek
    • Economic and Environmental Geology
    • /
    • v.51 no.1
    • /
    • pp.15-26
    • /
    • 2018
  • The spatio-temporal variations of nitrate concentrations in groundwater of Jeju Island were evaluated by an analysis of time series groundwater quality data (N = 21,568) that were collected from regional groundwater monitoring (number of wells = 4,835) for up to 20 years between 1993 and 2015. The median concentration of $NO_3-N$ is 2.5 mg/L, which is slightly higher than those reported from regional surveys in other countries. Nitrate concentrations of groundwater in wells tend to significantly vary according to different water usage (of the well), administrative districts, and topographic elevations: nitrate level is higher in low-lying agricultural and residential areas than those in high mountainous areas. The Mann-Kendall trend test and Sen's slope analysis show that nitrate concentration in mid-mountainous areas tends to increase, possibly due to the expansion of agricultural areas toward highland. On the other hand, nitrate concentrations in the Specially Designated Groundwater Quality Protection Zones show the temporally decreasing trend, which implies the efficiency of groundwater management actions in Jeju. Proper measures for sustainable groundwater quality management are suggested in this study.