• Title/Summary/Keyword: efficiency of scale

Search Result 3,082, Processing Time 0.042 seconds

Study of CO2 Carbonation-Regeneration Characteristics of Potassium-Based Dry Sorbents According to Water Vapor Contents of Inlet Gas and Regeneration Temperature in the Cycle Experiments of Bubbling Fluidized-Bed Reactor (회분식 기포유동층 반응기에서 K-계열 건식흡수제의 주입수분농도 및 재생반응온도에 따른 CO2 흡수-재생 반응특성 연구)

  • Park, Keun-Woo;Park, Yeong Seong;Park, Young Cheol;Jo, Sung-Ho;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.349-354
    • /
    • 2009
  • In this study, a bubbling fluidized-bed reactor was used to study $CO_2$ capture from flue gas using a potassium-based dry sorbent. A dry sorbent, manufactured by the Korea Electric Power Research Institute, consists of 35% of $K_2CO_3$ for $CO_2$ absorption and 65% of supporters for mechanical strength. $H_2O$, a reactant of the carbonation reaction, was supplied in the reactor as a form of saturated water vapor at a given temperature. The experiment of the regeneration reaction was performed by raising up to a given temperature using $N_2$ as a fluidization gas. It was indicated that sorption capacity and regenerability of dry sorbents showed high-efficiency at $1.97\;mol\;H_2O/mol\;CO_2$ and $400^{\circ}C$, respectively. The regenerated sorbent samples were analyzed by TGA to confirm the extent of the reaction. When the regeneration temperature was $150^{\circ}C$, the regenerability of dry sorbents was about 60%, which was capable of applying those sorbents to a two-interconnected fluidized-bed reactor system with continuous solid circulation. The results obtained in this study can be used as basic data for designing and operating a large scale $CO_2$ capture process with two fluidized-bed reactors.

Effects of Operation Parameters on Pollutants Removal in a Lab-Scale Multi-Layered Soil Filtration System (하천 수질정화를 위한 실험실 규모 다단식 토양여과 시스템에서 오염물질 제거에 미치는 운전인자의 영향)

  • Won, Se-Yeon;Ki, Dong-Won;Yoon, Min-Hyeok;Maeng, Sung-Kyu;Ahn, Kyu-Hong;Park, Joon-Hong;Song, Kyung-Guen
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.91-96
    • /
    • 2012
  • In this study we investigated the effects of operational parameters of a multi-layered soil filtration (filter depth, filtration velocity, and continuous/intermittent operation) on removal of pollutants in river water. As filter depth increased removal of all the pollutants (COD, TP, TN, and $NH_4$-N) was increased because the increase in filter depth increased in contact time between media and pollutants. The removal of TP and $NH_4$-N more increased with the increase in filter depth, comparing to the biological COD removal which was performed only in the top layer, since the removal mechanism of TP and $NH_4$-N was physicochemical process occurring throughout the whole layers. However, the reduction in filtration velocity resulted in decrease of removal all the pollutants removal due to shorter retention time. Biological COD removal was more influenced with the reduction in filtration velocity (longer retention time), than the removal of TP and $NH_4$-N. Because biological process was occurred only in the top layer which has relatively shorter retention time, comparing with physicochemical process occurred throughout whole media. Therefore, it is desirable that the operation parameters be controlled toward increasing retention time, in order to achieve efficient pollutants removal. The change in operation mode (continuos vs. intermittent operations) did not provide significant effects on the pollutant treatment efficiency by the multi-layered soil filtration system. Our findings suggest that for stable long-term operation it should be considered keeping conditions for biological activity and accelerating clogging.

Evaluation of Pollutant Removal Efficiency in Environmentally Friendly Full-scale Constructed Wetlands for Treating Domestic Sewage during Long-term Monitoring (장기 모니터링을 통한 환경친화형 인공습지 하수처리장의 수질정화효율 평가)

  • Seo, Dong-Cheol;Jo, In-Seong;Lim, Seok-Cheon;Lee, Byeong-Ju;Park, Seong-Kyu;Cheon, Yeong-Seok;Park, Jong-Hwan;Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • A constructed wetland which was composed of aerobic and anaerobic areas was evaluated for 3 years to effectively treat the sewage produced in farming and fishing communities. For 3 years in a constructed wetland, biochemical oxygen demand(BOD), chemical oxygen demand(COD), suspended solids(SS), total nitrogen(T-N), and total phosphorus(T-P) in effluent were 0.2${\sim}$11.8, 1.0${\sim}$41.9, 1.1${\sim}$6.5, 4${\sim}$60 and 0.02${\sim}$3.51 mg/L, respectively. Removal rate of BOD, COD and SS in effluent were 97, 92 and 99%, respectively, in the third year. As time goes by, removal rate of T-N and T-P in treated water in aerobic area and effluent were gradually increased in a constructed wetland. In the third year, removal rate in effluent were 62 and 73%, respectively. By the seasons, removal rate of BOD, COD, SS, T-N and T-P were 97${\sim}$98, 87${\sim}$91, 99, 43${\sim}$61 and 76${\sim}$86%, respectively. Removal rate of BOD, COD, SS and T-P were not affected by the seasons, but that of T-N in winter and spring were decreased than the other seasons.

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.

A Study Bioremediation of Tidal Flat by Microorganism in Pilot Scale Test (환경정화 미생물에 의한 갯벌의 생물학적 정화에 대한 파일럿 규모의 연구)

  • Choi, Hye Jin;Han, Young Sun;Park, Doo Hyun;Oh, Bo Young;Hur, Myung Je;Jo, Nam-Gyu;Kim, Young Hee;Kim, Jong-Guk
    • Journal of Life Science
    • /
    • v.24 no.10
    • /
    • pp.1110-1117
    • /
    • 2014
  • Tidal flats are continuously contaminated by human activities. This study assessed the bioremediation efficiency of tidal flat soil using microcosm reactors and microorganisms originating from the tidal area. We screened 135 bacterial strains that produce extracellular enzymes from the tidal area located in the North port of Incheon bay. Two bacterial strains (Pseudoalteromonas sp. and IC35 Halothiobacillus neapolitanus IC_S22) were selected and used in the microcosm reactors, which were specially designed to functionally mimic the ecological conditions of the tidal flats. Pseudoalteromonas sp. IC35 was selected based on its relatively high activity of the enzymes amylase, cellulose, lipase, and protease. Halothiobacillus neapolitanus IC_S22 was selected for oxidation of sulfur. The M1 and M2 microcosm reactors were operated by continuous feeding of seawater under the same conditions, but M2 was first inoculated with Pseudoalteromonas sp. IC35 before the seawater feeding. The initial COD in both the M1 and M2 microcosm reactors was 320 mg/l. The final COD was 21 mg/l (M1) and 7 mg/l (M2). The M3 and M4 microcosm reactors were operated by continuous feeding of seawater under the same conditions, but M4 was first inoculated with H. neapolitanus IC_S22. The initial sulfate concentration in both the M3 and M4 microcosm reactors was 660 mg/l, and the maximum sulfate concentration was 1,360 mg/l (M3) and 1,600 mg/l (M4).

EMERGY Analysis of Korean Fisheries (한국수산업의 EMERGY 분석)

  • SOHN Ji-Ho;SHIN Sung-Kyo;CHO Eun-Il;LEE Suk-Mo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.5
    • /
    • pp.689-700
    • /
    • 1996
  • Fisheries products have to be produced and maintained by work processes from the environment, sometimes helped by people. In Korean fisheries both environmental production and its economic use are included within the windows of system approach. EMERGY is the sum of all inputs expressed as one form of solar energy required directly and indirectly to make a product. Calculating EMERGY flows into Korean fisheries evaluates the real wealth contributed by environmental production and its economic use. Several indices calculated from EMERGY analysis table and a three-arm diagram give perspective on the type and efficiency of the environmental uses. Net EMERGY yield ratio is a measure of its net contribution to the economy beyond its own operation. For adjacent waters fisheries in Korea, the net contribution to the economy is 11.85 or higher, which is a stimulus to the economy that is able to purchase it. EMERGY investment ratio measures the intensity of the economic development and the loading of the environment. The ratio for Korean fisheries as a whole is 0.50, for the adjacent waters fisheries 0.09 and for the shallow-sea cultures 1.28, which is lower than the same index for the industry of the developed country (7.0). The component of environment drawn into production are large compared to purchased investment in Korean fisheries. Much more EMERGY is contained in fisheries products than in the paid services used to process the products. The EMERGY exchange ratio for Korean fisheries as a whole is 6.98, for the adjacent waters fisheries is 10.69 and for the shallow-sea cultures is 1.25. Using market values to evaluate wealth of environment resources is found to be many times too small. Money is paid only to people for their contribution, and never to the environment for its contribution. Macroeconomic value is the appropriate measure for discussing large-scale considerations of an economy, including environment and human goods & services.

  • PDF

Removal Effects of Chlorophyll-a and Cyanobacteria Using Laboratory-scale Biomanipulation Tests (실험적 생물조절 기법을 이용한 엽록소 및 남조류 제거 효과)

  • Lee, Sang-Jae;Lee, Jae-Yon;Lee, Jae-Hoon;Bae, Dae-Yeul;Lee, Eui-Hang;Han, Jung-Ho;Hwang, Soon-Jin;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.86-92
    • /
    • 2008
  • This study was conducted to determine removal effect on phytoplankton (chlorophyll-${\alpha}$ as whole algae) and cyanobacteria by a fish Pseudorasbora parva and macroinvertebrate Palaemon paucidens in September 2006. Three treatments with 25 (T1), 50 (T2) and 100 (T3) individuals along with control (C1, no input fish), and two treatments with 25 (T4) and 50 (T5) individuals along with control (C1) were made for fish and macroinvertebrate, respectively. The initial concentrations of chlorophyll-${\alpha}$ $(Chl_i)$ in each 10L test tank were set up for the levels of $95{\sim}100{\mu}g\;L^{-1}$ and the daily values were monitored in the test tank during 7 days. In the lab tests, P. parva did not show Chl-${alpha}$ removal effect; the removal rate of Chl-${alpha}$ for P. parva was -58% in T1, -56% in T2, and 61% in T3 during the test period. In contrast, P. paucidens. in the treatments of T4 and T5 removed the phytoplankton effectively and the removal effect were appeared to be 33% and 22%, respectively. Also, P. paucidens showed high feeding efficiency in the removal of cyanobacteria. The levels of cyanobacteria were greatly lowed from 6,048 to 927 cells $mL^{-1}$ in T4 and from 6,539 to 1,053 cells $mL^{-1}$ in T5, resulting in 85% and 84% in the removal effect, respectively. Our results for biomanipulation tests suggest that P. paucidens may be used as a potential candidate organism for algae control in spite of the preliminary results by laboratory tests.

A Study on the Forest Vegetation of Deogyusan National Park (덕유산 국립공원 삼림식생에 관한 연구)

  • Kim, Chang-Hwan;Oh, Jang-Geun;Lee, Nam-Sook
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • From March 2012 to January 2013, this study was conducted as a part of the project for making a precise electronic ecological zoning map of vegetation on a highly reduced scale of 1 to 5,000 with a view to improving management efficiency of national parks and enlarging the availability of the data produced from the basic research monitoring the resources of national parks. For the research accuracy and rapidity, a vegetation map was specially created for the on-the-site-vegetation research. To make the map more meticulous, we categorized the vegetation database into five groups: broadleaved forest, coniferous forest, mixed forest, rock vegetation and miscellaneous one. After comparing the results of the data built for the vegetation research and the actual research findings, it was made clear that vegetation of both categories was almost the same in case of broad-leaved forest with 72.20% and 78.45% respectively, and also equivalent in other groups like, for example, coniferous forest (16.70%, 13.41%), mixed forest (9.50%, 7.49%) and rock vegetation (0.60%, 0.15%). According to the precise vegetation map produced from the research, the deciduous broad-leaved forest was the most widely prevalent type in the correlated hierarchical classification of vegetation, occupying 65.78% of the overall vegetation. It was followed by mountain valley forest (15.17%), coniferous forest (10.90%), and plantation forest (7.00%) in order. It is particularly noteworthy that Mt. Deogyusan national park has retained a very stable and versatile forest vegetation in the outstanding state since approximately 20% of the mountain turns out to belong to the I grade vegetation conservation classification which contains climax forests, unique vegetation, subalpine vegetation, matured stands which are older than 50 years and etc.

Behavior of Steel Fiber-Reinforced Concrete Exterior Connections under Cyclic Loads (반복하중을 받는 강섬유 보강 철근콘크리트 외부 접합부의 거동 특성)

  • Kwon, Woo-Hyun;Kim, Woo-Suk;Kang, Thomas H.K.;Hong, Sung-Gul;Kwak, Yoon-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.711-722
    • /
    • 2011
  • Beam-column gravity or Intermediate Moment frames subjected to unexpected large displacements are vulnerable when no seismic details are provided, which is typical. Conversely, economic efficiency of those frames is decreased if unnecessary special detailing is applied as the beam and column size becomes quite large and steel congestion is caused by joint transverse reinforcement in beam-column connections. Moderate seismic design is used in Korea for beam-column connections of buildings with structural walls, which are to be destroyed when the unexpected large earthquake occurs. Nonetheless, performance of such beamcolumn connections may be substantially improved by the addition of steel fibers. This study was conducted to investigate the effect of steel fibers in reinforced concrete exterior beam-column connections and possibility for the replacement of some joint transverse reinforcement. Ten half-scale beam-column connections with non-seismic details were tested under cyclic loads with two cycles at each drift up to 19 cycles. Main test parameters used were the volume ratio of steel fibers (0%, 1%, 1.5%) and joint transverse reinforcement amount. The test results show that maximum capacity, energy dissipation capacity, shear strength and bond condition are improved with the application of steel fibers to substitute transverse reinforcement of beam-column connections. Furthermore, several shear strength equations for exterior connections were examined, including the proposed equation for steel fiber-reinforced concrete exterior connections with non-seismic details.

A Practice-Oriented Study on Sawdust File Filteration Composting of High Moisture Pig Slurry (고수분 돈분슬러리의 톱밥여과 퇴비화 현장적용 연구)

  • Ryoo, J.W.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.129-138
    • /
    • 2008
  • This study was carried out to investigate the operating characteristics, water balance and chemical properties of compost during the composting with pig slurry on-farm trial. The composting plant with sawdust pile filteration was done in a forced aeration inside a house and equipped with a turning machine moving on a rails. The composting pit was 4.6m wide, 53m long and the maximum height was 2m. A field scale aerobic composting facility was tested the composting efficiency of high moisture pig slurry. The sawdust materials remained 6 months. Pig slurry was added to compost pile every other day during 6 months run. The temperature in compost pile and compost house, and input and output of moisture were measured during composting process. The result are summarized as follows; 1. The temperature of compost was varied in range of at $22.4^{\circ}C{\sim}71.1^{\circ}C$. After turning, the composting temperature decreased to $50^{\circ}C{\sim}36^{\circ}C$ during $3{\sim}5$ hours, and then raised to $64.5^{\circ}C$ 2. The temperature of compost house was maintained $20^{\circ}C{\sim}30^{\circ}C$, and relative humidity was varied in range of $50{\sim}99%$. 3. BOD, CODcr and SS of leachate water was reduced 89.5%, 81.2%, 97.5%, respectively. 4. The content of heavy metal in the final compost was lower those of Korea standards. 5. The amount of effluent was 10.2%. Total evaporation during composting Period were 74.8%. The amount of slurry per $1m^3$ sawdust was $3.16m^3$ without treatment of effluent output.

  • PDF