• Title/Summary/Keyword: efficiency of scale

Search Result 3,082, Processing Time 0.03 seconds

Reduction of the Nitrogen in the Secondary Effluent by the Hybrid Sequential Aerobic-Anoxic Natural System (자연현상을 이용한 질산화-탈질공정에 의한 하수처리장 유출수의 질소제거)

  • Kim, Young-Chul;Chung, Paul-Gene;An, Ik-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.323-329
    • /
    • 2005
  • In this paper, performance of a hybrid sequential aerobic-anaerobic natural system was investigated. Continuous aerobic and anoxic conditions were created by alternatively placing waste stabilization pond (WSP) and wale. hyacinth pond (WHP). Two pilot-scale treatment lines were built and operated; The first consists of WSP integrated with WHP and the second of WSP connected with Dark Pond(DP), namely control system ponds which were used to examine the effects of water hyacinth on nitrification and de-nitrification. The overall performance in nitrogen was 86% reduction in WSP-WHP and 36% in WSP-control pond system. Nitrogen was mostly removed by nitrification and de-nitrification which simultaneously occurred in the same water hyacinth ponds. For the de-nitrification, benthic layer was found out to be adequate support as a carbon source. In addition, WSP-WHP system was very effective in reducing phosphorus. Overall P removal efficiency in WSP-WHP is 81%, while it is only 16% in WSP-control. difference in phosphorus reduction between those two systems is thought to be caused by the plants and probably their roots producing extra-cellular materials, but these aspects need to be further studied.

Oxygen Transfer and Hydraulic Characteristics in Bubble Column Bioreactor Applied Fine Bubble Air Diffusing System (미세기포 산기장치를 적용한 타워형 생물반응기의 산소전달 및 수력학적 특성)

  • Lee, Seung-Jin;Ko, Kyeong-Han;Ko, Myeong-Han;Yang, Jae-Kyeong;Kim, Yong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.772-779
    • /
    • 2012
  • For improving performance of conical air diffuser generating fine bubble, both experimental and numerical simulation method were used. After adapting diffusers inner real scale bubble column, suitable for various diffuser submergence, the effect of diffuser submergence on oxygen transfer performance such as Oxygen Transfer Coefficient ($K_{L}a_{20}$) and Standard Oxygen Transfer Efficiency (SOTE) was investigated empirically. As flow patterns for various diffuser number and submergence were revealed throughout hydrodynamic simulation for 2-phase fluid flow of air-water, the cause of the change for oxygen transfer performance was cleared up. As results of experimental performance, $K_{L}a_{20}$ was increased slightly by 7% and SOTE was increased drastically by 39~72%, 5.6% per meter. As results of numerical analysis, air volume fraction, air and water velocity in bioreactor were increased with analogous flow tendency by increasing diffuser number. As diffuser submergence increased, air volume fraction, air and water velocity were decreased slightly. Because circulative co-flow is determinant factor for bubble diffusion and rising velocity, excessive circulation intensity can result to worsen oxygen transfer by shortening bubble retention time and amount.

The Simultaneous Nitrification and Organics Oxidation of Wastewater in Airlift Biofilm Reactors (공기리프트 생물막 반응기에서의 폐수 질화 및 유기물 동시산화)

  • 서일순;허충희
    • KSBB Journal
    • /
    • v.16 no.6
    • /
    • pp.573-578
    • /
    • 2001
  • The effects of organic supplement (acetate) and dissolved oxygen concentration on the nitrification rate of wastewater were investigated in the 27.7 L pilot-scale airlift biofilm reactor with the granular activated carbon media of 0.613 mm diameter. The ammonium oxidation rate increased stepwise up to 5 kg N/㎥$.$d at the riser air velocity of 0.063 m/s, when the air velocity and the ammonium loading rate were raised alternately. The nitrite build-up was observed during the early stage of the biofilm formation, which disappeared after the reactor operation of 128 days. As increasing the organic loading rate, the organic oxidation rate increased up to 25.0 kg COD/㎥$.$d with the removal efficiency of 94% but the oxidation rates of ammonium and nitrite decreased. The oxidation rates of ammonium and nitrite increased with the dissolved oxygen concentrations. When the pure oxygen was sparged, the ammonium oxidation rate was almost five times higher than that with air at the same velocity.

  • PDF

Evaluation of Flexural Behavior of Prestressed Composite Beams with Corrugated Webs (파형웨브 프리스트레스트 합성보의 휨거동 평가)

  • Oh, Jae-Yuel;Lee, Deuck-Hang;Kim, Kang-Su;Kang, Hyun;Lee, Sofia;Bang, Yong-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.39-40
    • /
    • 2010
  • The demands for longer span and reduction of story height have greatly increased as building structures become much larger and higher in recent years. Although the development of flexural members for reducing story height or making long span has been studied by many researchers and engineers, there is still a lack of efficient systems that meet these two demands simultaneously. This study aimed at developing a new composite beam system suitable for long span and reduction of story height, and proposed a prestressed composite beam with corrugated web. It has great resistance against non-symmetric construction load due to its strong out-of-plane shear strength with relatively small member height as well as good constructability and economic efficiency by removing/minimizing form work. The corrugated webs also make accordion effect introducing larger effective prestressing force to top and bottom flanges, which causes larger upward camber reducing the member deflection. Five full-scale specimens with key test parameters, which are web sectional shapes and number of drape points, were tested to understand their flexural behavior and to verify the performance of the proposed method. The experimental test results showed that the proposed prestressed composite beam had greater flexural strength and stiffness than the ordinary non-prestressed composite beam.

  • PDF

Effects of Change in Heat Release Rate on Unsteady Fire Characteristics in a Semi-Closed Compartment (반밀폐된 구획에서 발열량 변화에 따른 비정상 화재특성)

  • Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.75-83
    • /
    • 2012
  • An experimental study was conducted to investigate the effects of change in heat release rate on unsteady fire characteristics of under-ventilated fire in a semi-closed compartment. A standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time using a spray nozzle located at the center of enclosure. Temperature, heat flux, species concentrations and heat release rate were continuously measured and then global equivalence ratio (GER) concept was adopted to represent the unsteady thermal and chemical characteristics inside the compartment. It was observed that there was a significant difference in unsteady behavior between global and local combustion efficiency, and the GERs predicted by ideal and measured heat release rate were also shown different results in time. The unsteady behaviors of temperature, heat flux and species concentrations were represented well using the GER concept. It was important to note that CO concentration was gradually decreased with the increase in GER after reaching its maximum value in the range of 2.0~3.0 of global equivalence ratio. In addition, the experimental data on unsteady thermal and chemical behaviors obtained in a semi-closed compartment will be usefully used to validate a realistic fire simulation.

Algorithms of the VLSI Layout Migration Software (반도체 자동 이식 알고리즘에 관한 연구)

  • Lee, Yun-Sik;Kim, Yong-Bae;Sin, Man-Cheol;Kim, Jun-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.712-720
    • /
    • 2001
  • Algorithms from the research of the layout migration were proposed in the paper. These are automatic recognition algorithm for the VLSI devices from it, graph based construction algorithm to maintain the constraints, dependencies, and design rule between the devices, and high speed compaction algorithm to reduce size of the VLSI area and reuse the design with compacted size for the new technology. Also, this paper describes that why proposed algorithms are essential for the era of the SoC (System on a Chip), design reuse, and IP DB, which are the big concerns in these days. In addition to introduce our algorithms, the benchmark showed that our performance is superior by 27 times faster than that of the commercial one, and has better efficiency by 3 times in disk usage.

  • PDF

A Study on Control of Access to Internal Network Information and Authority Set Up Management for Client by Class (제한된 내부 네트워크 정보 접근제어와 계층별 클라이언트 권한설정 관리에 관한 연구)

  • Seo, Woo-Seok;Park, Jae-Pyo;Jun, Moon-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.287-293
    • /
    • 2012
  • It has been only few years that various contents information subject for information processing system has been remarkably increased in online. If we say the year 2000 is the technology based year when deluge of information and data such as real time sharing, the time since after 2000 until 2011 has been a period plentiful of application based functions and solutions. Also, as the applicable range of these information process systems extends, individual information effluence has been social issues twice in 2009 and 2010. Thus now there are continuous efforts made to develop technologies to secure and protect information. However, the range problem has been extended from the illegal access from outside to the legal access from internal user and damages by agents hidden in internal information process system and client system. Therefore, this study discusses the necessity for the studies on efficiency based information security by control of access to internal information and authority setting for administrator and internal users. Based on the result of this study, it provides data that can be used from SOHO class network to large scale for information security method.

Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part I: Performance Estimation of FDS) (구획화재에서 환기조건의 변화가 화재특성에 미치는 영향(Part I: FDS의 성능평가))

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.131-138
    • /
    • 2010
  • Experimental and numerical studies were conducted to investigate the thermal and chemical characteristics of heptane fires in a full-scale ISO 9705 room. Representative fire conditions were considered for over-ventilated fire (OVF) and under-ventilated fire (UVF). Fuel flow rate and doorway width were changed to create OVF and UVF conditions. Detailed comparisons of temperature and species concentrations between experimental and numerical data were presented in order to validate the predictive performance of FDS (Fire Dynamic Simulator). The OVF and UVF were explicitly characterized with distributions of temperature and product formation measured in the upper layer, as well as combustion efficiency and global equivalence ratio. It was shown that the numerical results provided a quantitatively realistic prediction of the experimental results observed in the OVF conditions. For the UVF, the numerically predicted temperature showed reasonable agreement with the measured temperature. The predicted steady-state volume fractions of $O_2$, $CO_2$, CO and THC also agreed quantitatively with the experimental data. Although there were some limitations to predict accurately the transient behavior in terms of CO production/consumption in the UVF condition, it was concluded that the current FDS was very useful tool to predict the fire characteristics inside the compartment for the OVF and UVF.

Analysis of Factors Influencing the Performance of Technology Transfer on National R&D by Research Actors (연구수행 주체에 따른 국가R&D 기술이전 성과 영향요인 분석)

  • Kim, Mi-Sun;Yeon, Seung-Min;Kim, Jae-Soo;Lee, Byeong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.559-570
    • /
    • 2015
  • As national R&D is increased in scale, technology transfer has garnered more attention in terms of utilizing R&D outcomes. In this study, we analyzed influencing factors to technology transfer, as a way of utilizing R&D results, using data on national R&D. The analyses was performed with 3 subjects: university, government research institute and industry. When royalty is used as a dependent variable to measure the performance outcomes of technology transfers, the analysis showed that R&D funds have positive influence on all three subjects. In terms of government research institute, the influence was significant whether the location is the capital area or Daejeon city. With regards to industry, factors such as whether the project is a cooperative research, applied research, and the research to technology transfer period were found to have remarkable influence. On the other hand, when the number of cases of technology transfer was used as a dependent variable, the analysis indicated that R&D funds have significant impact on university, while for government research institute, the significant influencing factors include both R&D funds and the research to technology transfer period, and for industry have positive influence on applied research. It is therefore necessary to make differentiated policies considering the R&D organizations in order to improve the efficiency of technology transfer performance.

Parameterization and Application of Regional Hydro-Ecologic Simulation System (RHESSys) for Integrating the Eco-hydrological Processes in the Gwangneung Headwater Catchment (광릉 원두부 유역 생태수문과정의 통합을 위한 지역 생태수문 모사 시스템(RHESSys)의 모수화와 적용)

  • Kim, Eun-Sook;Kang, Sin-Kyu;Lee, Bo-Ra;Kim, Kyong-Ha;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.2
    • /
    • pp.121-131
    • /
    • 2007
  • Despite the close linkage in changes between the ecological and hydrological processes in forest ecosystems, an integrative approach has not been incorporated successfully. In this study, based on the vegetation and hydrologic data of the Gwangneung headwater catchment with the Geographic Information System, we attempted such an integrated approach by employing the Regional Hydro-Ecologic Simulation System (RHESSys). To accomplish this, we have (1) constructed the input data for RHESSys, (2) developed an integrated calibration system that enables to consider both ecological and hydrological processes simultaneously, and (3) performed sensitivity analysis to estimate the optimum parameters. Our sensitivity analyses on six soil parameters that affect streamflow patterns and peak flow show that the decay parameter of horizontal saturated hydraulic conductivity $(s_1)$ and porosity decay by depth (PD) had the highest sensitivity. The optimization of these two parameters to estimate the optimum streamflow variation resulted in a prediction accuracy of 0.75 in terms of Nash-Sutcliffe efficiency (NSec). These results provide an important basis for future evaluation and mapping of the watershed-scale soil moisture and evapotranspiration in forest ecosystems of Korea.