• Title/Summary/Keyword: effective parameter

Search Result 1,653, Processing Time 0.031 seconds

The Function and Symptoms of Ankle Joint in the Distal Tibial Fractures Treated by Nailing (족관절 기능과 증상을 중심으로 평가한 경골 원위부 골절에서의 금속정 치료 결과)

  • Kim, Byoung-Min;Bae, Su-Young;Roh, Jae-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.86-92
    • /
    • 2008
  • Purpose: To evaluate the safety and prognostic factors of intramedullary nailing of distal tibia fractures in terms of function and symptoms of the ankle joint. Materials and Methods: We retrospectively analyzed 22 distal tibial fractures with intramedullary nailing. The mean duration of follow-up was 43 months. We reviewed medical records to describe each case. We measured radiographic parameters such as fracture configuration, arthritic change of the ankle joint and status of reduction. We also assessed clinical results by AOFAS ankle hind foot scoring system, degree of pain by VAS and range of motion to find out prognostic factors for functional result of the ankle joint. Results: Bone healing was obtained in all cases without any wound complications. Mean AOFAS ankle score was 94. There were 4 cases with mild (VAS<3/10) ankle pain and 2 cases with mild limitation of ankle motion. The comminution of fracture had a significant relationship with delayed angular deformity of ankle joint (p=0.032). There was no other significant parameter affecting ankle joint function except the location of nail-end. Conclusion: Intramedullary nailing in distal tibia fracture is a safe and effective procedure. But further study may need to evaluate the relationship between the position of nail-end and the function of ankle joint.

  • PDF

The Relationship between the Compression Grade of Vertebrae and Outcome after Percutaneous Vertebroplasty in Patients with Osteoporotic Vertebral Compression Fractures

  • Kim, Jung-Min;Lee, Jong-Won;Hur, Jin-Woo;Kim, Seung-Hyun;Lee, Hyun-Koo;Kim, Myoung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.5
    • /
    • pp.350-354
    • /
    • 2005
  • Objective : The aim of this study is to assess the immediate and long-term efficacy of percutaneous vertebroplasty for treating painful vertebral osteoporotic fractures. Methods : A retrospective review of 149patients who had undergone 167 vertebroplasty procedures for osteoporotic fractures was performed. Clinical, radiologic, and procedural datas were analyzed as parameters of prognostic significance, including age, sex, bone marrow density score, symptom duration, bone cement filling grade, number of fractured vertebrae, compression grade of vertebrae, leakage of bone cement, volume of bone cement injected and complications. Results : In 158 of the 167 procedures assessed, immediate pain relief was obtained [94.6%]. The extent of collapse of the vertebral body was assessed as a parameter for prognostic significance [p=0.015]. Three months postoperatively, no improvement of the pain was observed in four of the 167 procedures that had undergone the vertebroplasty [2%]. At long-term follow-up, the improvement of pain was not correlated with the compression grade of vertebrae [p=0.420]. Conclusion : The immediate outcome of vertebroplasty are less effective in vertebrae more collapsed.

Fatigue Strength Evaluation of Self-Piercing Riveted Al-5052 Joints (셀프 피어싱 리베팅한 Al-5052 접합부의 피로강도 평가)

  • Kang, Se Hyung;Hwang, Jae Hyun;Kim, Ho Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.1-6
    • /
    • 2015
  • Self-piercing riveting (SPR) is receiving more recognition as a possible and effective solution for joining automotive body panels and structures, particularly for aluminum parts and dissimilar parts. In this study, static strength and fatigue tests were conducted using coach-peel and cross-tension specimens with Al-5052 plates for evaluation of fatigue strength of the SPR joints. For the static experiment results, the fracture modes are classified into pull-out fracture due to influence of plastic deformation of joining area. During the fatigue tests for the coach-peel and cross-tension specimens with Al-5052, interface failure mode occurred on the top substrate close to the rivet head in the most cycle region. There were relationship between applied load amplitude $P_{amp}$ and life time of cycle N, $P_{amp}=715.5{\times}N^{-0.166}$ and $P_{amp}=1967.3{\times}N^{-0.162}$ were for the coach-peel and cross- tension specimens, respectively. The finite element analysis results for specimens were adopted for the parameters of fatigue lifetime prediction. The relation between SWT fatigue parameter and number of cycles was found to be $SWT=192.8N_f^{-0.44}$.

Multi-mode Radar Signal Sorting by Means of Spatial Data Mining

  • Wan, Jian;Nan, Pulong;Guo, Qiang;Wang, Qiangbo
    • Journal of Communications and Networks
    • /
    • v.18 no.5
    • /
    • pp.725-734
    • /
    • 2016
  • For multi-mode radar signals in complex electromagnetic environment, different modes of one emitter tend to be deinterleaved into several emitters, called as "extension", when processing received signals by use of existing sorting methods. The "extension" problem inevitably deteriorates the sorting performance of multi-mode radar signals. In this paper, a novel method based on spatial data mining is presented to address above challenge. Based on theories of data field, we describe the distribution information of feature parameters using potential field, and makes partition clustering of parameter samples according to revealed distribution features. Additionally, an evaluation criterion based on cloud model membership is established to measure the relevance between different cluster-classes, which provides important spatial knowledge for the solution of the "extension" problem. It is shown through numerical simulations that the proposed method is effective on solving the "extension" problem in multi-mode radar signal sorting, and can achieve higher correct sorting rate.

An Efficient Data Path Synthesis Algorithm for Low-Power (저전력 데이타-경로를 위한 효율적인 고수준 합성 알고리즘)

  • Park, Chae-Ryung;Kim, Young-Tae;Kim, Tae-Hwan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.2
    • /
    • pp.227-233
    • /
    • 2000
  • In this paper, we present a new high-level data path synthesis algorithm which solves the two design problems, namely, scheduling and allocation, with power minimization as a key design parameter. From the observations in previous works on data path synthesis for low power, we derive an integer programming (IP) formulation for the problem, from which we then develop an efficient heuristic to carry out the scheduling and allocation simultaneously. Our experimental results demonstrate that the proposed algorithm is very effective in saving power consumption of circuits significantly.

  • PDF

The Characteristic of Control Response of BLDC using a Fuzzy PI Controller (퍼지 PI 제어기를 사용한 BLDC 제어 응답특성)

  • Yoon, Yong-Ho;Kim, Jae-Moon;Kim, Duk-Heon;Won, Chung-Yuen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1978-1983
    • /
    • 2011
  • BLDC motor is used in a wide variety of industrial and servo applications. Its features and advantages mainly consist in high value of torque/inertia ratio, high efficiency with speed range and high dynamic performance. This paper deals with the speed control of a trapezoidal type brushless DC motor using Fuzzy PI controller. The conventional PI controller has been widely used in industrial applications. If we select a optimal PI control gain, the PI controller shows very good control performance. But it is very difficult to find the optimal PI control gain. Fuzzy control does not need any model of plant and is basically adaptive and gives robust performance for plant parameter variation. Therefore the combinations of conventional PI controller and fuzzy controller seem to be very effective. This paper deals with PI controller with 4-rule based fuzzy controller. The proposed fuzzy PI controller increases the control performance of the conventional PI controller. Simulation and experimental results show that fuzzy PI controller has a good robustness regarding the improper tuned PI controller.

Congestion Management in Deregulated Power System by Optimal Choice and Allocation of FACTS Controllers Using Multi-Objective Genetic Algorithm

  • Reddy, S. Surender;Kumari, M. Sailaja;Sydulu, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.467-475
    • /
    • 2009
  • Congestion management is one of the technical challenges in power system deregulation. This paper presents single objective and multi-objective optimization approaches for optimal choice, location and size of Static Var Compensators (SVC) and Thyristor Controlled Series Capacitors (TCSC) in deregulated power system to improve branch loading (minimize congestion), improve voltage stability and reduce line losses. Though FACTS controllers offer many advantages, their installation cost is very high. Hence Independent System Operator (ISO) has to locate them optimally to satisfy a desired objective. This paper presents optimal location of FACTS controllers considering branch loading (BL), voltage stability (VS) and loss minimization (LM) as objectives at once using GA. It is observed that the locations that are most favorable with respect to one objective are not suitable locations with respect to other two objectives. Later these competing objectives are optimized simultaneously considering two and three objectives at a time using multi-objective Strength Pareto Evolutionary Algorithms (SPEA). The developed algorithms are tested on IEEE 30 bus system. Various cases like i) uniform line loading ii) line outage iii) bilateral and multilateral transactions between source and sink nodes have been considered to create congestion in the system. The developed algorithms show effective locations for all the cases considered for both single and multiobjective optimization studies.

A Load Identification Method for ICPT System Utilizing Harmonics

  • Xia, Chen-Yang;Zhu, Wen-Ting;Ma, Nian;Jia, Ren-Hai;Yu, Qiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2178-2186
    • /
    • 2018
  • Online identification of load parameters is the premise of establishing a stable and highly-efficient ICPT (Inductive Coupled Power Transfer) system. However, compared with pure resistive load, precise identification of composite load, such as resistor-inductance load and resistance-capacitance load, is more difficult. This paper proposes a method for detecting the composite load parameters of ICPT system utilizing harmonics. In this system, the fundamental and harmonic wave channel are connected to the high frequency inverter jointly. The load parameter values can be obtained by setting the load equation based on the induced voltage of secondary-side network, the fundamental wave current, as well as the third harmonic current effective value received by the secondary-side current via Fourier decomposition. This method can achieve precise identification of all kinds of load types without interfering the normal energy transmission and it can not only increase the output power, but also obtain higher efficiency compared with the fundamental wave channel alone. The experimental results with the full-bridge LCCL-S type voltage-fed ICPT system have shown that this method is accurate and reliable.

Heat Transfer Characteristics on Toroidal Convection Loop with Nanofluids (나노유체 토로이달 자연대류 루프에서의 열전달 특성)

  • Jang, Ju-Chan;Rhi, Seok-Ho;Lee, Chung-Gu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.235-241
    • /
    • 2009
  • Experimental studies on single-phase toroidal circulation loop(thermosyphon) have been performed in the present study with Ag-nanofluids as a working fluids. The present paper deals with an experimental study on the heat transfer behavior of single-phase toroidal loop. Toroidal loop charged with nanofluid has been constructed and a number of tests have been carried out. Different geometric parameter, e.g., orientation has been investigated. The tests were conducted employing two fluids: distilled water and Ag-nanofluid of various volume concentrations. The experiments at Rayleigh number from $10^5$ to $10^6$ showed a systematic and slight deterioration in natural convective heat transfer. It was observed that the deterioration due to the particle concentration was in the range of 5-10%. At a given particle concentration of 0.05%, abrupt decrease in the Nusselt number and the Raleigh number was observed. The present study with toroidal loop shows that the application of nanofluids for heat transfer intensification should not be decided only by the effective thermal conductivity with increasing particle concentration.

Impedance Characteristics of an Expansion-Resonator Type Pulsation Attenuator(Attenuation on Flow and Pressure Ripple form a Hydraulic Piston Pump) (팽창 공명기형 맥동 감쇠기의 임피던스 특성(유압용 피스톤 펌프의 유량.압력맥동 감쇠))

  • 이상기
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.1
    • /
    • pp.88-95
    • /
    • 2000
  • In this paper, an expansion-resonator type pulsation attenuator is proposed to absorb and attenuate flow an pressure ripple with high frequencies generated from hydraulic control systems. The basic principle of a pulsation attenuator proposed here is applied to propagation, reflection, absorption of pressure waves at the cross section of discontinuity and resonance in the pipeline. It has advantage of the compact size and high degree fo freedom for installation in hydraulic systems. The design scheme based on distributed parameter pipeline system with dissipative viscous compressible model is developed. To investigate the reduction of flow and pressure ripple with high frequencies produced by swash plate type axial piston pump, two kinds of attenuators are manufactured. It is experimently confirmed that the spectral intensity of flow and pressure ripple with high frequencies from the pump are reduced up to about 20$^{\circ}$~30dB by using attenuators proposed here. The calculated results were in good agreement with the measured values. From there sults of this study, it is shown that an expansion-resonator type pulsation attenuator is effective in a wide frequency ranges to attenuate the flow and pressure ripple from hydraulic components.

  • PDF