• Title/Summary/Keyword: effective parameter

Search Result 1,653, Processing Time 0.033 seconds

Weld Quality Monitoring System Development Applying A design Optimization Approach Collaborating QFD and Risk Management Methods (품질 기능 전개법과 위험 부담 관리법을 조합한 설계 최적화 기법의 용접 품질 감시 시스템 개발 응용)

  • Son, Joong-Soo;Park, Young-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.2
    • /
    • pp.207-216
    • /
    • 2000
  • This paper introduces an effective system design method to develop a customer oriented product using a design optimization process and to select a set of critical design paramenters,. The process results in the development of a successful product satisfying customer needs and reducing development risk. The proposed scheme adopted a five step QFD(Quality Function Deployment) in order to extract design parameters from customer needs and evaluated their priority using risk factors for extracted design parameters. In this process we determine critical design parameters and allocate them to subsystem designers. Subsequently design engineers develop and test the product based on these parameters. These design parameters capture the characteristics of customer needs in terms of performance cost and schedule in the process of QFD, The subsequent risk management task ensures the minimum risk approach in the presence of design parameter uncertainty. An application of this approach was demonstrated in the development of weld quality monitoring system. Dominant design parameters affect linearity characteristics of weld defect feature vectors. Therefore it simplifies the algorithm for adopting pattern classification of feature vectors and improves the accuracy of recognition rate of weld defect and the real time response of the defect detection in the performance. Additionally the development cost decreases by using DSP board for low speed because of reducing CPU's load adopting algorithm in classifying weld defects. It also reduces the cost by using the single sensor to measure weld defects. Furthermore the synergy effect derived from the critical design parameters improves the detection rate of weld defects by 15% when compared with the implementation using the non-critical design parameters. It also result in 30% saving in development cost./ The overall results are close to 95% customer level showing the effectiveness of the proposed development approach.

  • PDF

Optimization for the Design Parameters of Electric Locomotive Overhaul Maintenance Facility (전기 기관차 중수선 시설의 설계 변수 최적화)

  • Um, In-Sup;Cheon, Hyeon-Jae;Lee, Hong-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.2
    • /
    • pp.222-228
    • /
    • 2010
  • In this paper, we propose a optimization approach for the Electric Locomotive Overhaul Maintenance Facility (ELOMF), which aims at the simulation optimization so as to meet the design specification. In simulation design, we consider the critical path and sensitivity analysis of the critical (dependent) factors and the design (independent) parameters for the parameter selection and reduction of the metamodel. Therefore, we construct the multi-objective non-linear programming. The objective function is normalized for the generalization of design parameter while the constraints are composed of the simulation-based regression metamodel for the critical factors and design factor's domain. Then the effective solution procedure based on the pareto optimal solution set is proposed. This approach provides a comprehensive approach for the optimization of Train Overhaul Maintenance Facility(TOMF)'s design parameters using the simulation and metamoels.

A Video Encoding Scheme using Adaptive Spatial Resolution Control for Mobile Video Applications (모바일 비디오 응용을 위한 적응적 공간 해상도 제어 인코딩 기법)

  • Lee, Hee-Jung;Lee, Yong-Hee;Lee, Jong-Hun;Shin, Heon-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7C
    • /
    • pp.654-662
    • /
    • 2009
  • Video streams for mobile video streaming can be encoded to fit the available network bandwidth by controlling three factors: temporal resolution, spatial resolution, and picture quality. The controlling of picture quality by modifying the quantization parameter (QP) is most widely used. In this paper, we demonstrate that reducing the spatial resolution adaptively can be more efficient in terms of picture quality and energy consumption in low bit-rate environment, and present a model to find the optimal spatial resolution for the available bandwidth. Adaptive spatial resolution control scheme is especially effective when the bandwidth between the video server and the mobile device varies considerably with time, and when the mobile device is sensitive to energy consumption. Our scheme can improve the picture quality by approximately O.5dB and reduce energy consumption by more than 50% compared to the conventional video coding in low bit-rate environment.

Assessment of Degradation Rate Coefficient and Temperature Correction Factor by Seasonal Variation of Concentration and Temperature in Livestock Wastewater Treatment in Field Scale (현장수준의 축산폐수처리에 있어서 계절별 농도 및 온도변화에 따른 분해반응계수 및 온도보정계수의 산정)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 1996
  • This study was performed to calculate the degration rate coefficient, operating parameters to meet the effluent standards, and the temperature adjustment coefficients to each parameter of pollution by seasonal variation of concentration and temperature of influent in livestock wastewater treatment by sequencing batch reactor process in field scale. The followings are the conclusions that were derived from this study. 1. In the field, temperature of livestock wastewater in reactor was 20.3$\circ$C in summer and 6.0$\circ$C in winter. The ratio of BOD:TKN: T-P in influent was 100:80:7. BOD loadings in winter and spring were 0.26 and 0.43 kg $BOD/m^3$ day, respectively. Those in summer and fall were 0.25 and 0.13 kg $BOD/m^3$ day, respectively. 2. The degradation rate coefficient for TKN was larger in summer and fall in which temperature was high than that in which temperature was high than that in winter and spring in which concentration was high. On the contrary, the phosphorus uptake rate was larger in winter and spring than that in summer and fall. 3. The hydraulic retention time in winter and spring was longer than that in summer and fall. Especially, in order to meet the standard for TKN of 120 mg/l in winter in which temperature of wastewater was 6.0$\circ$C, as the MLSS concentration was increased from 4, 000 to 7, 000 mg/l, the hydraulic retention time was increased from 212 to 121 hours. But, in order to shorten that less than 121 hours for the economical wastewater treatment, countermeasure to increase temperature of wastewater in the reactor should be considered. 4. the temperature adjustment coefficients for BOD, $COD_{Mn}$, TKN and T-P were 1.0241, 1.0225, 1.0541 and 1.0495, respectively. Namely, the treatment of TKN was most sensitively affected by temperature. For the purpose of the effective removal of nitrogen and phosphorus which are sensitive to temperature, it is necessary to keep the temperature of livestock wastewater more than 20$\circ$C which is the temperature of it in summer.

  • PDF

Bone Region Extraction by Dual Energy X-ray Absorbtion Image Decomposition (Dual Energy X-ray 흡수 영상의 분해를 통한 뼈 영역 추출)

  • Kwon, Ju-Won;Cho, Sun-Il;Ahn, Young-Bok;Ro, Yong-Man
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1233-1241
    • /
    • 2009
  • Over the 50 percents of women who are older than 45 years have osteoporosis. Because people hardly recognize this disease by themselves, the researches that measure bone mineral density have been doing widely to detect osteoporosis in the early stage. The most widely used methods for bone mineral density measurement are based on the X-ray imaging. Among them, DEXA(Dual-energy X-ray Absorptiometry) imaging is one of the important methods in bone mineral density measurement. DEXA images are useful methods to increase diagnosis efficiency by reducing anatomic noise as two images obtained from two different energy levels. However, it has some problems to a calibration parameter determined by the heuristic method for bone extraction. In this paper, we propose the method to extract bone in DEXA image using calibration parameter based on anatomic attenuation coefficient. The experimental results reveal that the proposed method is effective.

  • PDF

Effect of Extractant on the Color Characteristics of Natural Colorant Extracts (천연색소의 색 특성에 미치는 추출용매의 영향)

  • Lee, Young-Hee;Park, Young-Kwang;Baek, Young-Mee;Kim, Jung-Soo;Lee, Dong-Jin;Kim, Han-Do
    • Textile Coloration and Finishing
    • /
    • v.28 no.1
    • /
    • pp.1-13
    • /
    • 2016
  • Natural colorant extracts were obtained by extraction from tumeric root, gardenia seeds, mugwort and green tea using water, methanol, ethanol and acetone as extractants at room temperature for 3 hours under shaking condition(180rpm) with liquor ratio(solid:solvent; 1:100). The main pigment components of tumeric root, gardenia seeds, mugwort and green tea are known to be curcumin, crocin, chlorophyll b and epigallocatechin gallate, respectively. The effects of the kind of extractant and pH on the color characteristics of natural colorant extracts were investigated. The solubility parameters of pigment components were determined to find adequate extractant. The solubility parameters of curcumin, crocin, chlorophyll b and epigallocatechin gallate were found to be 27.85, 29.40, 19.48 and $37.97(J/cm^3)^{1/2}$. As expected, solvents that have a solubility parameter similar to that of pigment component were generally found to be effective to obtain pigment extracts having high visible absorbance(A). The extract(pigment/solvent) with high visible absorbance was generally found to have low $L^*$(lightness) and high Chroma($C^*$, purity).

Heavy Metal Toxicity Test in Moina macrocopa with Enzyme Activity (효소활성을 이용한 Moina macrocopa의 중금속 독성 검정)

  • Park, Yong-Seok;Jung, So-Jung;Oh, Nu-Ri;Choi, Eun-Joo;Rhie, Ki-Tae
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.1
    • /
    • pp.17-22
    • /
    • 2008
  • A rapid, inexpensive enzymatic method is proposed for indirect water quality testing in terms of heavy metal toxicity. The activity of glucose-6-phosphate dehydrogenase was applied for heavy metal toxicity test as an effective criterion in water quality. The toxicity of Pb (lead) and Cd (cadmium) for water flea, Moina macrocopa, were evaluated for $2{\sim}8\;days$ with variables of mobilization ability. And the reproduction impairment of Moina macrocopa were investigated as the parameter of chronic toxicity twst for Pb and Cd. As a result, the $EC_{50}$ for immobilization of Moina macrocopa were Pb and Cd were 1.6749 and 0.4683, respectively. The values of reproducive impairment to Moina macrocopa for Pb and Cd were 9.5938 and 8.3264 in $EC_{50}$. A significant alteration of G6PDH (Glucose-6-phosphate dehydrogenase) activity of Moina macrocopa was observed when Cd and Pb were treated in media. The results obtained indicate that G6PDH activity of Moina macrocopa can be used as an indicative parameter in aquatic toxicity tests for heavy metals.

Optical Design for High Brightness Direct Type Backlight Unit Using Medical LCD Application (의료용 초고휘도 LCD 소자를 위한 직하형 Backlight의 최적설계)

  • Han, Jeong-Min;Kim, Won-Bae
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.28-31
    • /
    • 2016
  • In this study, it was investigated about optical simulation in highg brightness and high uniformity direct-type backlight design for medical application. Direct-type backlight has been used high-brightness backlight such as Medical LCD application. The key parameter in designing direct-type backlight was consists of three geometrical dimension such as the distance of two lamps, the gap of lamp and reflection plate and the number of lamps. It has many of variations in optical design and it causes the different properties in backlight system. It shows the best values of above parameters; 26mm of the distance of two lamps, 4.5mm of the gap of lamp and reflection plate and 16 lamps. And we produced the specimen as above condition, and acquired good result in backlight such as the value of the brightness is 6423 nit in center of emission area and less than 5% in brightness uniformity. It shows the effective ways of designing backlight system using optical simulation method for medical LCD application.

A Parameter Study of Internally Confined Hollow Reinforced Concrete Piers (내부 구속 중공 RC 교각의 매개변수 연구)

  • Choi, Jun-Ho;Yoon, Ki-Yong;Han, Taek-Hee;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.17-24
    • /
    • 2010
  • The hollow RC(Reinforced concrete) pier has the merit of lightweight pier compared with solid RC pier. However, the hollow RC pier shows a low ductile behavior due to brittle failure of inside concrete. To overcome this problem, the internally confined hollow reinforced concrete column has been developed. In this study, the behavior of internally confined hollow RC piers were evaluated with safety ratio, ductility, total material cost, the total weight of the pier, etc. The chosen parameters for the study are hollow ratio, thickness of internal steel tube, intervals between vertical re-bars, numbers of horizontal re-bars, and strength of concrete. As a result of parameters study, the usage of a minimum necessary thickness of the internal steel tube is the most effective.

Polarized Light Emission of Liquid Crystalline Polymer Blends (액정성 고분자 블렌드의 편발광)

  • 김영철;조현남;김동영;홍재민;송남웅
    • Polymer(Korea)
    • /
    • v.24 no.2
    • /
    • pp.211-219
    • /
    • 2000
  • Fluorene-based light emitting polymer blends with liquid crystalline characteristics were studied on effective energy transfer and dichroic characteristics. Incorporating 0.5 wt% of the non-liquid crystalline into the liquid crystalline polymer suppressed the PL emission at 420 nm on photoexcitation at 360 nm, but generated a new PL emission of the non-liquid crystalline polymer at 480 nm. The highest PL intensity at 480 nm, which was 13 times stronger than those of the two polymers before blending, was observed for a blend with 2.0 wt% of the non-liquid crystalline polymer. When the molecules of the blends were aligned on a rubbed polyimide surface by a heating-cooling process, the dichroic ratio and the order parameter were 2.0 and 0.25, respectively. Time-correlated single photon counting (TCSPC) study revealed that the time required for energy transfer between the two chromophores was shortened by 93 ps when the blends were aligned on the rubbed polyimide surface by the heating-cooling process. The thermal treatment also enhanced the energy transfer efficiency by 9%.

  • PDF