• 제목/요약/키워드: effective factor

검색결과 5,322건 처리시간 0.032초

RFIC 설계에 응용 가능한 90nm 공정 기반 인덕터의 Quality factor 및 Effective inductance 분석 (Analysis of Quality factor and Effective inductance of Inductor for RF Integrated Circuits in 90nm CMOS Technology)

  • 장성용;신종관;권혁민;권성규;성승용;황선만;장재형;이가원;이희덕
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.128-133
    • /
    • 2013
  • 본 논문에서는 RFIC 설계에 응용 가능한 인덕터의 Quality factor 및 Effective inductance를 비교 분석하기 위해 Octagonal 인덕터를 90nm CMOS 공정을 이용하여 제작하였다. 내부반경을 설계변수로 갖는 인덕터의 경우 내부반경이 증가함에 따라 Quality factor가 감소하고 Effective inductance의 값이 증가하였다. 회전수를 설계변수로 갖는 인덕터의 경우 금속의 회전수가 증가함에 따라 Quality factor의 값이 감소하고 Effective inductance의 값이 증가하는 것을 확인하였다. 따라서 RFIC 회로 설계에 있어서 인덕터의 구조는 Q-factor 및 inductance 각각의 상대적 중요도에 따라 선택 되어져야 된다고 할 수 있다.

도시 소유역 유효불투수율의 민감도 분석 (Sensitivity analysis of effective imperviousness estimation for small urban watersheds)

  • 김대근;고영찬
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.181-187
    • /
    • 2009
  • In this study, a runoff hydrograph and runoff volume were calculated by using the kinetic wave theory for small urban watersheds based on the concept of low impact development(LID), and the effective imperviousness was estimated based on these calculations. The degree of sensitivity of the effective imperviousness of small watersheds to the impervious to pervious area ratio, infiltration capability, watershed slope, roughness coefficient and surface storage depth was then analyzed. From this analysis, the following conclusions were obtained: The effective imperviousness and paved area reduction factor decreased as the infiltration capability of pervious area increased. As the slope of watersheds becomes sharper, the effective imperviousness and the paved area reduction factor display an increasing trend. As the roughness coefficient of impervious areas increases, the effective imperviousness and the paved area reduction factor tend to increase. As the storage depth increases, the effective imperviousness and the paved area reduction factor show an upward trend, but the increase is minimal. Under the conditions of this study, it was found that the effective imperviousness is most sensitive to watershed slope, followed by infiltration capability and roughness coefficient, which affect the sensitivity of the effective imperviousness at a similar level, and the storage depth was found to have little influence on the effective imperviousness.

실질적인 X-Factor에 관한 고찰 (A Study on the Effective X-Factor)

  • 장재관
    • 한국운동역학회지
    • /
    • 제15권3호
    • /
    • pp.153-159
    • /
    • 2005
  • The purpose of this study was to investigate the Effective X-Factor in golf swing. The term X-Factor means the relative rotation of shoulders with respect to hips during the golf swing. To ascertain the Effective X-Factor that resulted in a high club head speed at impact six golfers' swing motions were videotaped and analyzed using three-dimensional techniques. The results can be summarized as follows. The standard deviations of the professionals' average club head speeds were higher than the amateurs'. This means that the professionals' swing skills were better than amateurs' in driving accuracy and consistency. As the club head speeds were increased gradually the X-Factors and the club head speeds had reached to the subjects' average club head speeds, but the X-Factors and the club head speeds were not increased above the subjects' average club head speeds. The X-Factor Stretch early in the down swing was existed and Professional stretched values were higher than the amateurs. In conclusion my research results suggested that the increase in Effective X-Factors had no relationship to the increase in club head speeds.

확장계수를 적응한 기둥의 유효좌굴길이 계수 산정 (Evaluation of Effective Length Factor by Using an Amplification Factor)

  • 최동호;유훈;신재인;김성연
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.369-374
    • /
    • 2007
  • For a stability design of steel frames, AISC-LRFD specification recommend to use Alignment Chart and story-based methods in order to determine an effective budding length. Recently, elastic buckling analysis, which is the method that calculate the effective length of members using eigenvalue of the overall structure, has been widely used in practical design of steel frames because this method can be performed effectively and automatically by computers. However, it can in some cases lead to unexpectedly large effective length in column having small axial forces. Therefore, this paper propose a method using elastic buckling analysis, which estimate a proper effective buckling length for all members having a small axial force. For verification of proposed method, it is compared with system based approach and stiffness distribution factor method. As a result, proposed method can rationally solve a problem in some case of column having small axial force. Also, adoption range for proposed method is established.

  • PDF

Validation of a Model for Estimating Individual External Dose Based on Ambient Dose Equivalent and Life Patterns

  • Sato, Rina;Yoshimura, Kazuya;Sanada, Yukihisa;Sato, Tetsuro
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.77-85
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, a model was developed to estimate the external exposure doses for residents who were expected to return to their homes after evacuation orders were lifted. However, the model's accuracy and uncertainties in parameters used to estimate external doses have not been evaluated. Materials and Methods: The model estimates effective doses based on the integrated ambient dose equivalent (H*(10)) and life patterns, considering a dose reduction factor to estimate the indoor H*(10) and a conversion factor from H*(10) to the effective dose. Because personal dose equivalent (Hp(10)) has been reported to agree well with the effective dose after the FDNPS accident, this study validates the model's accuracy by comparing the estimated effective doses with Hp(10). The Hp(10) and life pattern data were collected for 36 adult participants who lived or worked near the FDNPS in 2019. Results and Discussion: The estimated effective doses correlated significantly with Hp(10); however, the estimated effective doses were lower than Hp(10) for indoor sites. A comparison with the measured indoor H*(10) showed that the estimated indoor H*(10) was not underestimated. However, the Hp(10) to H*(10) ratio indoors, which corresponds to the practical conversion factor from H*(10) to the effective dose, was significantly larger than the same ratio outdoors, meaning that the conversion factor of 0.6 is not appropriate for indoors due to the changes in irradiation geometry and gamma spectra. This could have led to a lower effective dose than Hp(10). Conclusion: The estimated effective doses correlated significantly with Hp(10), demonstrating the model's applicability for effective dose estimation. However, the lower value of the effective dose indoors could be because the conversion factor did not reflect the actual environment.

Effective length factor for columns in braced frames considering axial forces on restraining members

  • Mahini, M.R.;Seyyedian, H.
    • Structural Engineering and Mechanics
    • /
    • 제22권6호
    • /
    • pp.685-700
    • /
    • 2006
  • The effective length factor is a familiar concept for practicing engineers and has long been an approach for column stability evaluations. Neglecting the effects of axial force in the restraining members, in the case of sway prevented frames, is one of the simplifying assumptions which the Alignment Charts, the conventional nomographs for K-Factor determination, are based on. A survey on the problem reveals that the K-Factor of the columns may be significantly affected when the differences in axial forces are taken into account. In this paper a new iterative approach, with high convergence rate, based on the general principles of structural mechanics is developed and the patterns for detection of the critical member are presented and discussed in details. Such facilities are not available in the previously presented methods. A constructive methodology is outlined and the usefulness of the proposed algorithm is illustrated by numerical examples.

유효 유전율을 이용한 MIC 구조에서의 유전체 공전기 양호도 측정 (Q-Factor Measurement of a Dielectric Resonator in an MIC Environment Using Effective Dielectric Constant)

  • 탁윤도;최준호;이주섭;김영식
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.243-247
    • /
    • 2000
  • In this parer, Q-factor measurement method for a dielectric resonator in an MIC environment using the effective dielectric constant is proposed. The effective dielectric constant technique is applied to both radial and axial directions. The proposed method shows that the accuracy of the Q-factor measurement is to be improved with 2% ~ 3% relative error.

  • PDF

유한요소해석에서 탄성 및 비탄성 기둥에 대한 유효길이 계수의 자동산정 (Automatic Generation of Effective Length Factor of Elastic and Inelastic Column in the Finite Element Analysis)

  • 이성우;이선구;이형우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 가을 학술발표회논문집
    • /
    • pp.24-31
    • /
    • 1993
  • In the design of column, computation of effective length factor for calculation of allowable compressive stress is inevitable. In this study. computer code which automatically generates effective length factor in the finite element analysis is developed. The program is developed to be used for orthogonal and nonorthogonal frame structure. Some i1lustrative examples verify that the computation results we correct for various cases.

  • PDF

Effective Length of Reinforced Concrete Columns in Braced Frames

  • Tikka, Timo K.;Mirza, S. Ali
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권2호
    • /
    • pp.99-116
    • /
    • 2014
  • The American Concrete Institute (ACI) 318-11 permits the use of the moment magnifier method for computing the design ultimate strength of slender reinforced concrete columns that are part of braced frames. This computed strength is influenced by the column effective length factor K, the equivalent uniform bending moment diagram factor $C_m$ and the effective flexural stiffness EI among other factors. For this study, 2,960 simple braced frames subjected to short-term loads were simulated to investigate the effect of using different methods of calculating the effective length factor K when computing the strength of columns in these frames. The theoretically computed column ultimate strengths were compared to the ultimate strengths of the same columns computed from the ACI moment magnifier method using different combinations of equations for K and EI. This study shows that for computing the column ultimate strength, the current practice of using the Jackson-Moreland Alignment Chart is the most accurate method for determining the effective length factor. The study also shows that for computing the column ultimate strength, the accuracy of the moment magnifier method can be further improved by replacing the current ACI equation for EI with a nonlinear equation for EI that includes variables affecting the column stiffness and proposed in an earlier investigation.

색채와 광원이 쇼윈도 전시효과에 미치는 영향 (A Experimental Study on the Influence of the Display Effect by Color and Light Source in Show Window)

  • 이정옥;김현지
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권4호
    • /
    • pp.49-54
    • /
    • 1995
  • This paper is an experimental study on the influence of the demonstration effect by color and light source in show window. This experiment used semantic differentical method in model show window of actual size. The important outcomes of this study are summarized below. 1. In the result by factor analysis, three factors are classified. They are diversity, emotion, lightness. 2. In the study on the influence by light source, incandescence lamp is the most effective light source in every items. 3. In the result of the study on the influence by color source, according to each factor bring out following result ; Green is the most effective in diversity factor and ligthness factor. Yellow is the most effective in emotion factor.

  • PDF