• 제목/요약/키워드: effective eccentricity

검색결과 49건 처리시간 0.022초

Dispersion and Nonlinear Properties of Elliptical Air Hole Photonic Crystal Fiber

  • Rao, MP Srinivasa;Singh, Vivek
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.525-531
    • /
    • 2018
  • The effect of eccentricity on dispersion and nonlinear properties of a photonic crystal fiber having elliptical air holes is investigated using a fully vectorial effective index method. It is found that the effective refractive index increases with increase of eccentricity. The dependence of dispersion and nonlinear properties of the PCF on the eccentricity of the air hole is investigated. It is revealed that eccentricity of the air hole affects the zero dispersion wavelength. Further, the nonlinear properties such as mode field area, nonlinear coefficient and self phase modulation of the Photonic crystal fibers are analyzed. The mode field area increases and the nonlinear coefficient decreases with increase in eccentricity. The variation of the self phase modulation with elliptical air hole is also discussed.

면진된 전단 거동 구조물의 층응답스펙트럼에 대한 편심효과 (In-Structure Response Spectra of Seismically Isolated Shear Buildings Considering Eccentricity Effect)

  • 이승재;김정한
    • 한국지진공학회논문집
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2024
  • For important structures such as nuclear power plants, In-Structure Response Spectrum (ISRS) analysis is essential because it evaluates the safety of equipment and components installed in the structure. Because most structures are asymmetric, the response can be affected by eccentricity. In the case of seismically isolated structures, this effect can be greater due to the difference between the center of mass of the structure and the center of rigidity of the isolator layer. Therefore, eccentricity effects must be considered when designing or evaluating the ISRS of seismically isolated structures. This study investigated the change of the ISRS of an isolated structure by assuming accidental eccentricity. The variables that affect the ISRS of the isolated structure were analyzed to see what additional impact they had due to eccentricity. The ISRS of the seismically isolated structure with eccentricity was amplified more than when there was non-eccentricity, and it was boosted more significantly in specific period ranges depending on the isolator's initial stiffness and seismic intensity. Finally, whether the displacement requirement of isolators can be applied to the variation of the ISRS due to eccentricity in the design code was also examined.

Tuned mass dampers for torsionally coupled systems

  • Pansare, A.P.;Jangid, R.S.
    • Wind and Structures
    • /
    • 제6권1호
    • /
    • pp.23-40
    • /
    • 2003
  • The steady state response of a torsionally coupled system with tuned mass dampers (TMDs) to external wind-induced harmonic excitation is presented. The torsionally coupled system is considered as one-way eccentric system. The eccentricity considered in the system is accidental eccentricity only. The performance of single tuned mass damper (TMD) optimally designed without considering the torsion is investigated for the torsionally coupled system and found that the effectiveness of a single TMD is significantly reduced due to torsion in the system. However, the design of TMD system without considering the torsion is only justified for torsionally stiff systems. Further, the optimum parameters of a single TMD considering the accidental eccentricity are obtained using numerical searching technique for different values of uncoupled torsional to lateral frequency ratio and aspect ratio of the system. The optimally designed single TMD system is found to be less effective for torsionally coupled system in comparison to uncoupled system. This is due to the fact that a torsionally coupled system has two natural frequencies of vibration, as a result, at least two TMDs are required which can control both lateral and torsional response of the system. The optimum damper parameters of different alternate arrangements such as (i) two identical TMDs placed at opposite corners, (ii) two independent TMDs and (iii) four TMDs are evaluated for minimum response of the system. The comparative performance of the above TMDs arrangements is also studied for both torsionally coupled and uncoupled systems. It is found that four TMDs arrangement is quite effective solution for vibration control of torsionally coupled system.

편심축하중을 받는 강섬유보강 콘크리트 기둥의 실험적 연구 (An Experimental Study on Eccentrically Loaded Steel Fiber Reinforced Concrete Columns)

  • 박홍용;안영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.857-860
    • /
    • 2000
  • An experimental study on the behavior of Steel Fiber Reinforced Concrete Columns under eccentric compression are presented. Forth-one columns were tested; the variables were column type, eccentricity of load, fiber contents, and longitudinal reinforcement ratio. The column size was $250\times160$ mm in cross section with an effective length of 1150 mm. Eccentricity of load was varied in the range from 1/6 to 1/2 times the column depth. This paper is to provides a framework for basic understanding of the steel fiber concrete columns.

Seismic behavior of reinforced concrete interior beam-column joints with beams of different depths

  • Xing, G.H.;Wu, T.;Niu, D.T.;Liu, X.
    • Earthquakes and Structures
    • /
    • 제4권4호
    • /
    • pp.429-449
    • /
    • 2013
  • Current Design Codes for Reinforced Concrete (RC) interior beam-column joints are based on limited experimental studies on the seismic behavior of eccentric joints. To supplement existing information, an experimental study was conducted that focused on the effect of eccentricity of the deeper beams with respect to the shallow beams. A total of eight one-third scale interior joints with beams of different depths were subjected to reverse cyclic loading. The primary variables in the test specimens were the amount of joint transverse reinforcement and the cross section of the shallow beams. The overall performance of each test assembly was found to be unsatisfactory in terms of joint shear strength, stiffness, energy dissipation and shear deformation. The results indicated that the vertical eccentricity of spandrel beams in this type of joint led to lower capacity in joint shear strength and severe damage of concrete in the joint core. Increasing the joint shear reinforcement was not effective to alter the failure mode from joint shear failure to beam yielding which is favorable for earthquake resistance design, whereas it was effective to reduce the crack width at the small loading stages. Based on the observed behavior, the shear stress of the joint core was suggested to be kept as low as possible for a safe and practical design of this type of joint.

비틀림 비정형을 가지는 학교건물의 편심율에 따른 좌굴방지가새형 이력댐퍼의 제진성능분석 (Analysis of Damping Performance of Hysteretic Dampers of Buckling restrained Braced Type According to eccentricity of school buildings with Torsional irregularities)

  • 김유성;이준호;김기철
    • 한국공간구조학회논문집
    • /
    • 제23권2호
    • /
    • pp.37-44
    • /
    • 2023
  • In the case of a school building, even though it is a regular structure in terms of plan shape, if the masonry infill wall acts as a lateral load resisting element, it can be determined as a torsionally irregular building. As a result, the strength and ductility of the structure are reduced, which may cause additional earthquake damage to the structure. Therefore, in this study, a structure similar to a school building with torsional irregularity was selected as an example structure and the damping performance of the PC-BRB was analyzed by adjusting the eccentricity according to the amount of masonry infilled wall. As a result of nonlinear dynamic analysis after seismic reinforcement, the torsional irregularity of each floor was reduced compared to before reinforcement, and the beams and column members of the collapse level satisfied the performance level due to the reduction of shear force and the reinforcement of stiffness. The energy dissipation of PC-BRB was similar in the REC-10 ~ REC-20 analytical models with an eccentricity of 20% or less. REC-25 with an eccentricity of 25% was the largest, and it is judged that it is effective to combine and apply PC-BRB when it has an eccentricity of 25% or more to control the torsional behavior.

Correlation between torsional vibration and translational vibration

  • Jeng, V.;Tsai, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제13권6호
    • /
    • pp.671-694
    • /
    • 2002
  • This paper presents theoretical investigation on the cross correlation between torsional vibration ($u_{\theta}$) and translation vibration ($u_x$) of asymmetrical structure under white noise excitation. The formula reveals that the cross correlation coefficient (${\rho}$) is a function of uncoupled frequency ratio (${\Omega}={\omega}_{\theta}/{\omega}_x$), eccentricity, and damping ratio (${\xi}$). Simulations involving acceleration records from fifteen different earthquakes show correlation coefficients results similar to the theoretical correlation coefficients. The uncoupled frequency ratio is the dominating parameter to ${\rho}$; generally, ${\rho}$ is positive for ${\omega}_{\theta}/{\omega}_x$ > 1.0, negative for ${\omega}_{\theta}/{\omega}_x$ < 1.0, and close to zero for ${\omega}_{\theta}/{\omega}_x$ = 1.0. When the eccentricity or damping ratio increases, ${\rho}$ increases moderately for small ${\Omega}$ (< 1.0) only. The relation among $u_x$, $u_{\theta}$ and corner displacement are best presented by ${\rho}$; a simple way to hand-calculate the theoretical dynamic corner displacements from $u_x$, $u_{\theta}$ and ${\rho}$ is proposed as an alternative to dynamic analysis.

수력 원통형 터빈 가이드 베어링의 저부하/저편심 성능향상 설계 - 패드 선단 테이퍼의 도입 (Low-Load/Low-Eccentricity Performance Improvement Designs for Hydro Power Application of Cylindrical Turbine Guide Bearings - Introduction of Pad Leading-Edge Tapers)

  • 이안성;장선용
    • Tribology and Lubricants
    • /
    • 제33권2호
    • /
    • pp.65-70
    • /
    • 2017
  • In vertical hydro/hydraulic power turbine-generator applications, traditionally, cylindrical turbine guide bearings (TGBs) are widely used to provide turbine runner shafts with smooth rotation guides and supports. All existing cylindrical TGBs with simple plain pads have drawbacks such as having no pressure generation and film stiffness at the no-load condition and in addition, at the low-load/low-eccentricity condition, having very low film stiffness values and lacking design credibility in the stiffness values themselves. In this paper, in order to fundamentally improve the low-load/low-eccentricity performance of conventional cylindrical TGBs and thus enhance their design-application availability and usefulness, we propose to introduce a rotation-directional leading-edge taper to each partitioned pad, i.e., a pad leading-edge taper. We perform a design analysis of lubrication performance on $4-Pad{\times}4-Row$ cylindrical TGBs to verify an engineering/technical usefulness of the proposed pad leading-edge taper. Analysis results show that by introducing the leading-edge taper to each pad of the cylindrical TGB one can expect a constant high average direct stiffness with a high degree of design credibility, regardless of load value, even at the low-load/low-eccentricity condition and also control the average direct stiffness value by exploring the taper height as a design parameter. Therefore, we conclude that the proposed pad leading-edge tapers are greatly effective in more accurately predicting and controlling rotordynamic characteristics of vertical hydro-power turbine-generator rotor-bearing systems to which cylindrical TGBs are applied.

모래지반에서 원형기초의 수직-모멘트 조합하중 지지력과 편심계수에 대한 수치해석 연구 (Numerical Studies on Combined VM Loading and Eccentricity Factor of Circular Footings on Sand)

  • 김동준;윤준웅;지성현;추연욱
    • 한국지반공학회논문집
    • /
    • 제30권3호
    • /
    • pp.59-72
    • /
    • 2014
  • 모래지반 표면에 위치한 강체 원형기초를 대상으로 수치해석을 통하여 수직-모멘트 조합하중 조건에서의 지지력을 구하였다. 지반은 Mohr-Coulomb 소성모델을 이용하여 모델링하였으며 관련흐름법칙을 적용하였고, 거친 기초 바닥면 조건에 대하여 검토하였다. 적은 수의 해석으로 조합하중 상관도를 산출할 수 있는 swipe 재하 방법과 통상적인 재하실험에서 적용되는 probe 재하 방법을 적용하여 비교한 결과, 두 방법은 유사한 결과를 나타내었다. 모멘트하중을 고려하기 위하여 전통적으로 사용되는 유효폭 및 유효면적 개념을 사용한 결과와 편심계수($e_{\gamma}$)를 사용한 방법들을 비교하였으며, 기존의 제안식들과 수치모델링으로 구해진 본 연구의 결과를 비교하였다. 수직-모멘트 조합하중 지지력의 내부마찰각에 따른 변화는 미미한 것으로 나타났으며, 유효폭 개념은 편심계수의 형태로 변환하여 원형기초에도 그대로 적용이 가능한 것으로 나타났다. 본 연구의 수치모델링 결과는 기존의 실험에 기반한 결과들에 비해 다소 작은 값을 주는 것으로 나타났으며, 편심 및 모멘트하중이 증가할수록 그 차이는 증가하였다. 수치모델링과 실험 결과가 차이를 나타내는 요인과 향후 연구 방향에 대하여 고찰하였다.

Should accidental eccentricity be eliminated from Eurocode 8?

  • Anagnostopoulos, S.A.;Kyrkos, M.T.;Papalymperi, A.;Plevri, E.
    • Earthquakes and Structures
    • /
    • 제8권2호
    • /
    • pp.463-484
    • /
    • 2015
  • Modern codes for earthquake resistant building design require consideration of the so-called accidental design eccentricity, to account for torsional response caused by several factors not explicitly considered in design. This provision requires that the mass centres in the building floor be moved a certain percentage of the building's dimension (usually 5%) along both the x and y axes and in both positive and negative directions. If one considers also the spatial combinations of the two component motion in a dynamic analysis of the building, the number of required analyses and combinations increases substantially, causing a corresponding work load increase for practicing structural engineers. Another shortcoming of this code provision is that its introduction has been based primarily on elastic results from investigations of oversimplified, hence questionable, one story building models. This problem is addressed in the present paper using four groups of eccentric braced steel buildings, designed in accordance with Eurocodes 3 (steel) and 8 (earthquake design), with and without accidental eccentricities considered. The results indicate that although accidental design eccentricities can lead to somewhat reduced inelastic response demands, the benefit is not significant from a practical point of view. This leads to suggestions that accidental design eccentricities should probably be abolished or perhaps replaced by a simpler and more effective design provision, at least for torsionally stiff buildings that constitute the vast majority of buildings encountered in practice.