• Title/Summary/Keyword: effective cusp

Search Result 24, Processing Time 0.018 seconds

A Structural Approach to On-line Signature Verification (구조적 접근방식의 온라인 자동 서명 겁증 기법)

  • Kim, Seong-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.4 s.36
    • /
    • pp.385-396
    • /
    • 2005
  • In this paper, a new structural approach to on-line signature verification is presented. A primitive pattern is defined as a part segmented by a local minimal position of speed. And a structural description of signature is composed of subpatterns which are defined as such forms as rotation shape, cusp shape and bell shape, acquired by composition of the primitives regarding the directional changes. As the matching method to find identical parts between two signatures, a modified DP(dynamic programming) matching algorithm is presented. And also, variation and complexity of local parts are computed from the training samples, and reference model and decision boundary are derived from these. Error rate, execution time and memory usage are compared among the functional approach, the parametric approach and the proposed structural approach. It is found that the average error rate can be reduced from 14.2% to 4.05% when the local parts of a signature are weighted and the complexity is used as a factor of decision threshold. Though the error rate is similar to that of functional approaches. time consumption and memory usage of the proposed structural approach are shown to be very effective.

  • PDF

Effects of bracket slot size during en-masse retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system

  • Kim, Ji-Yong;Yu, Won-Jae;Koteswaracc, Prasad N.K.;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.47 no.3
    • /
    • pp.158-166
    • /
    • 2017
  • Objective: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. Methods: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. Results: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. Conclusions: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

Effect of feeding a diet comprised of various corn silages inclusion with peanut vine or wheat straw on performance, digestion, serum parameters and meat nutrients in finishing beef cattle

  • Zhang, Hongrui;Zhang, Liyang;Xue, Xiao;Zhang, Xiaoxia;Wang, Hongyi;Gao, Tengyun;Phillips, Clive
    • Animal Bioscience
    • /
    • v.35 no.1
    • /
    • pp.29-38
    • /
    • 2022
  • Objective: The objective of this study was to compare the feeding value, meat nutrients and associative effects of a diet comprised of various corn silages inclusion with peanut vine or wheat straw in finishing beef cattle. Methods: One hundred and eighty Simmental crossbred beef steers were blocked and assigned to the follow treatments: i) whole plant corn silage-based diet (control, WPCS), ii) mixed forages-based diet (replacing a portion of corn silage with wheat straw, WPCSW), iii) corn stalklage-based diet (CS), and iv) sweet corn stalklage-based diet (SCS). Each group consisted of 5 repeated pens with 9 steers/pen. The diets were formulated to be isonitrogenous and isoenergetic with same forage to concentrate ratio. Experimental diets were fed for 90 d. Results: The effective ruminal degradability of dry matter and crude protein were highest for WPCS diet (p<0.05), for neutral detergent fiber was highest in SCS diet (p<0.05). The average daily gain was greater for cattle offered the WPCS diet, intermediate with WPCSW and SCS and lowest with CS (p<0.001). The concentration of non-esterified fatty acid in serum was higher for steers fed with CS and SCS diets than those offered WPCS and WPCSW steers (p<0.001). The treatments did not affect the general nutritional contents and amino acids composition of Longissimus dorsi of steers (p>0.05). Conclusion: The corn silage-based diet exhibited the highest feeding value. The sweet corn stalklage and wheat straw as an alternative to corn silage offered to beef cattle had limited influence on feeding value and meat nutrients. However, the value of a corn stalklage-based diet was relatively poor. To sum up, when the high quality forage resources, such as corn silage, are in short supply, or the growth rate of beef cattle decreases in the later finishing period, the sweet stalklage and wheat straw could be used as a cheaper alternative in feedlot cattle diet without sharp reducing economic benefits.