• 제목/요약/키워드: effect of operating conditions

검색결과 811건 처리시간 0.028초

가스터빈 압축기용 허니컴 래버린스 실의 실제 운전조건에 따른 누설량 특성 분석 (HONEYCOMB LABYRINTH SEAL LEAKAGE CHARACTERISTIC ANALYSIS WITH ACTUAL OPERATING CONDITIONS ON THE COMPRESSOR OF GAS TURBINE)

  • 임샛별;김민규;강율호;박원규
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.102-108
    • /
    • 2015
  • Recently, There are many studies in progress in order to improve the efficiency of the gas turbine. Leakage in losses of the gas turbine account for the largest proportion. Seal is a sealing device to reduce the flow from leaking by the pressure difference inside the turbine. Compressor has another value according to the shape and pressure conditions in each stage. Thus, it is necessary to seal design for boundary conditions in order to minimize leakage. At the actual operating conditions of the compressor, numerical analysis of honeycomb labyrinth seal was performed in accordance with pressure, temperature, rotor speed for CFD. As a result, when the temperature increases, the leakage is decreased. Also, when the pressure increases linearly with increased leakage, and there was no effect of the rotation speed.

해수제빙장치의 최적 운전 조건 탐색을 위한 실험적 연구 (Experimental Study for Investigating the Optimum Operating Conditions of a Seawater Ice Machine)

  • 이화;주우진;정석권
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.76-82
    • /
    • 2010
  • This paper investigates the optimum operating conditions to construct total automatic control system with high energy efficiency of a newly developed seawater ice machine. The machine has an electronic expansion valve(EEV) and a variable speed rotating drum with an evaporator installed inside. The coefficient of performance(COP) was used as an index to evaluate energy efficiency of the machine. At first, the opening angle of EEV was adjusted to obtain COP of the machine at a constant speed of the drum. Then, we checked seawater ice product versus opening angles of the EEV. Finally, effect of drum's rotating speed in response to product of seawater ice and seawater ice temperature were considered.

저온 수직평판에서 착상에 대한 운전조건의 영향 (The Effect of Operating Conditions on the Frost Formation in a Vertical Plate at a Low Temperature)

  • 이관수;이태희;김우승
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3305-3314
    • /
    • 1994
  • In this study, the influence of a frost formed on the vertical plate for different operating conditions(the temperature of the air, the humidity of the air, the velocity of the air, and the temperature of the cooling plate) is investigated. The performance of the heat exchanger is examined by introducing a parameter such as the energy transfer resistance. Correlations which relate frost density, frost thickness and energy transfer resistance to Reynolds number, air temperature and humidity, and cooling plate temperature are developed. Static pressure drop and air flow rate are expressed as a function of free flow area of air.

Static Synchronous Series Compensator(SSSC) 댐핑 제어 및 해석모형 (Damping Control Strategy and Analysis Model of Static Synchronous Series Compensator(SSSC))

  • 김학만;전영환;오태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.509-515
    • /
    • 2000
  • This paper addresses a damping control strategy of Static Synchronous Series Compensator(SSSC) and analysis model for stability study. The effect of injected voltage source generated by SSSC is modelled as equivalent load. This model is thought to be reasonable for the stability study because the dynamics of SSSC is very fast compared with that of power system. Damping controller of SSSC is based on Transient Energy Function method. The proposed control strategy is insensitive to the operating conditions like power flow level because control law depends on the phase angles. The proposed analysis model and control strategy was confirmed by WSCC 9 bus system and two area system. Especially, the robustness of proposed control strategy is demonstrated with respect to multiple operating conditions in two area system.

  • PDF

로터리 교반식 퇴비화 시설의 운전 조건 개선 (Improvement in the Operating Conditions of the Rotary Mixing Compost Plants)

  • 김은경;이택순;서정윤
    • 한국환경농학회지
    • /
    • 제15권3호
    • /
    • pp.355-361
    • /
    • 1996
  • The Purpose of this study was to investigate the effect of the Change in the operating conditions on rotary turning compost plants. The major parameters investigated were moisture content and mixing of the sawdust and pig farm wastewater. Pig farm scale composting plants with mixing rotary were used in this study. Wastes used for the study were sawdust, pig manure, urine and wastewater. When the moisture content was 75%, the compost product obtained from the plants had better physical characteristics than that obtained from the plants with moisture contents of 70%, 80% and 85%.(two a day mixing). When the turning was twice a day, the compost product obtained from the plants had better characteristics than that obtained from non-mixing.(moisture content 75%). C/N ratio, pH value and coliform bacterial population were stable in the compost.

  • PDF

An Experimental Study on the Performance of $CO_2$ Air-conditioning Cycle Equipped with an Ejector

  • Kim, Mo-Se;Lee, Jae-Seung;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권3호
    • /
    • pp.100-106
    • /
    • 2009
  • As an effort to prevent environmental problems caused by ozone depletion and global warming, alternative refrigerants are being developed, and one of the candidates is carbon dioxide. To overcome slightly low efficiency of $CO_2$ refrigeration system, air-conditioning cycle using an ejector was suggested. Ejector compensates throttling loss in an expansion device by reducing compression work. In this study, the ejector refrigeration cycle using $CO_2$ as a refrigerant is investigated to understand the effect of the mixing section diameter and refrigerant charge amount on the performance. If mixing section diameter is too large or too small, either cases show low performance. The optimum refrigerant charge amount which gives the best performance is found for standard operating conditions. The air-conditioning cycle was analyzed for several operating conditions.

로터리 압축기 내부의 오일 거동 가시화 및 정량화 (Visualization and Quantification of Oil Behavior inside Rotary Compressor)

  • 조필재;김윤석;이승갑;윤영;고한서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1580-1585
    • /
    • 2004
  • A quality of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from the compressor. Thus, the analysis of the oil behavior inside the compressor is required to prevent the problem. A tested rotary compressor with visualization windows has been manufactured in this study to investigate the oil behavior using developed visualization techniques. The oil behaviors at various operating conditions have been quantified to obtain the relationship with the outlet pressure inside the compressor. Also, the effect of the operating conditions on the quantity of the exhausted oil from the rotary compressor has been investigated using the visualization technique.

  • PDF

Reactive RF 마그네트론 스퍼터링법으로 Si(100) 기판에 MgO박막 제조시 증착변수의 영향 (Effect of Deposition Parameters on MgO Thin Films on Si(100) Substrates by Reactive RF Magnetron Sputtering)

  • 이영준;백성기
    • 한국세라믹학회지
    • /
    • 제31권6호
    • /
    • pp.643-650
    • /
    • 1994
  • Highly [100]-oriented MgO thin films were deposited on Si(100) single crystal substrates by reactive RF magnetron sputtering. The effects of substrate temperature, gas pressure, RF input powder, and gas composition on the characteristics of MgO thin films were studied. The higher substrate temperature and the lower operating pressure were, the better crystallinity of the deposited MgO thin films were. The influences of the RF input power and oxygen to argon ratio were very complex. The physical characteristics of the films changed dramatically with deposition conditions. Highly smooth and epitaxial MgO films were obtained at the deposition conditions as follows; subatrate temperature, $600^{\circ}C$; operating pressure, 10 mtorr; RF input power density, 2 W/$\textrm{cm}^2$; the percentage of oxygen, 10%.

  • PDF

직접 분사식 소형 과급 디젤엔진의 운전조건이 배기 배출물에 미치는 영향 (An Effect of Operating Conditions on Exhaust Emissions in a Small Turbocharged D.I. Engine)

  • 장세호;고대권;안수길
    • 동력기계공학회지
    • /
    • 제6권2호
    • /
    • pp.12-17
    • /
    • 2002
  • Recently, the world is faced with very serious problems related to the air pollution due to the exhaust emissions of the diesel engine. So, many of researchers have studied to reduce the exhaust emissions of diesel engine. This study was investigated for various exhaust emissions according to operating conditions in a turbocharged D.I. diesel engine. As a result of experiments in a test engine, the $CO_2\;and\;NO_x$ increased with increasing load, the $CO_2$ and CO decreased with increasing charge air pressure in manifold, the CO decreased with increasing cooling fresh water temperature, and the $NO_x$ decreased with worming cooling fresh water before engine start.

  • PDF