• Title/Summary/Keyword: effect of operating conditions

Search Result 815, Processing Time 0.027 seconds

An Experimental Study on the Estimation Flow-rate of Venturi Pump Using LightGBM (LightGBM을 이용한 수력 펌프 유량 추정의 실험적 연구)

  • Jin Beom Jeong;Jihwan Lee;Myeongcheol Kang
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.123-132
    • /
    • 2023
  • In disaster situations, to facilitate rapid drainage, electric underwater pumps are installed manually. This poses a high risk of electric shock accidents due to a short circuit, and a lot of time is required for hose connection and installation of electrical devices. To solve these problems, a Venturi pump using the venturi effect without external power is used. However, Venturi pumps that operate without external power make it difficult to install flow sensors such as electric devices; consequently, it is difficult to check the real-time flow rate. This paper proposes a flow estimation logic to replace the function of the flow sensor for the venturi pump . To develop the flow estimation logic, the flow characteristics of the venturi pump, according to the operating conditions, were checked. After that, the relationship with the flow rate of the venturi pump was defined using a pressure sensor corresponding to a low-cost sensor. Finally, an analysis of the estimation error was performed using the developed flow estimation logic.

Hydrogen Production from Wastewater in Takju Manufacturing Factory by Microbial Consortium (탁주제조공장 폐수로부터 혼합균주에 의한 수소생산)

  • Lee, Ki-Seok;Bae, Sang-Ok;Kang, Chang-Min;Chung, Seon-Yong
    • KSBB Journal
    • /
    • v.23 no.3
    • /
    • pp.199-204
    • /
    • 2008
  • Culture conditions for biological hydrogen production were investigated in wastewater of Takju manufacturing factory. Rhodobacter spaeroides KCTC1425, photosynthesis bacteria, and Enterobacter cloacae YJ-1, anaerobic bacteria were used. The hydrogen production were $195.3m{\ell}{\cdot}H_2/{\ell}$ broth for Rhodobacter spaeroides KCTC1425 and $271.8m{\ell}{\cdot}H_2/{\ell}$ broth for Enterobacter cloacae YJ-1 during 36 h. The hydrogen production increased with light intensity, and were highest over 12000Lux. In mixed culture of Rhodobacter spaeroides KCTC1425 and Enterobacter cloacae Y J-1, the optimum mixing ratio of hydrogen production was 20 and 80. Adding volume of yeast extract for maximum hydrogen production was 15 $g/{\ell}$, but there was no effect over that. $Na_2MoO_4$ was most effective among the inorganic salts, and the optimum volume was 0.4 $g/{\ell}$. In semi-continuous culture, total hydrogen production was $13086m{\ell}{\cdot}H_2/{\ell}$ broth for 144 h with operating period of 24 h.

Numerical Studies of Flow Characteristics and Particle Residence Time in a Taylor Reactor (테일러 반응기의 유동특성과 입자 체류시간에 관한 수치적 연구)

  • Lee, Hyeon Kwon;Lee, Sang Gun;Jeon, Dong Hyup
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.67-73
    • /
    • 2015
  • Using a computational fluid dynamics technique, the flow characteristics and particle residence time in a Taylor reactor were studied. Since flow characteristics in a Taylor reactor are dependent on the operating conditions, effects of the inlet flow velocity and reactor rotational speed were investigated. In addition, the particle residence time of $LiNiMnCoO_2$ (NMC), which is a cathode material in lithium-ion battery, is estimated in the Taylor vortex flow (TVF) region. Without considering the complex chemical reaction at the inlet, the effect of Taylor flow was studied. The results show that the particle residence time increases as the rotating speed increased and the flow rate decreased.

Studies on the Performance Variation of a Variable Speed Vapor Compression System under Fault and Its Detection and Diagnosis (가변속 증기압축 냉동시스템에서 고장시의 성능변화와 고장 감지 및 진단에 관한 연구)

  • Kim Minsung;Kim Min Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • An experimental study has been peformed to develop a scheme for fault detection and diagnosis(FDD) in a vapor compression refrigeration system. This study is to analyze fault effect on the system performance and to find efficient diagnosis rules for easy determination of abnormal system operation. The refrigeration system was operated with a variable speed compressor to modulate cooling capacity. The FDD system was designed to consider transient load conditions. Four major faults were considered, and each fault was detected over wide operating load range by separating the system response to the load change. Rule-based method was used to diagnose and classify the system faults. From the experimental results, COP degradation due to the faults in a variable speed system is severer than that in a constant speed system. The method developed in this study can be used in the fault detection of refrigeration systems with a variable speed compressor.

Tourniquet-Free Hand Surgery Using the One-per-Mil Tumescent Technique

  • Prasetyono, Theddeus O.H.
    • Archives of Plastic Surgery
    • /
    • v.40 no.2
    • /
    • pp.129-133
    • /
    • 2013
  • Background A pneumatic tourniquet is generally used to achieve a bloodless operation field in hand surgery. However, this has changed with tumescent solution-based wide-awake surgery. This study is a preliminary prospective case series study to elaborate the formula and indications of the tumescent technique in hand surgery without a tourniquet. Methods Seven patients (age range, 4 months to 37 years) underwent hand or upper extremity surgery for conditions such as nerve palsy, electric burn defect, fingertip injury, contracture, constriction ring syndrome, or acrosyndactyly. A "one-per-mil" tumescent solution (epinephrine 1:1,000,000+20 mg lidocaine/50 mL saline) was used to create a bloodless operating field without a tourniquet. Observation was performed to document the amount of solution injected, the operation field clarity, and the postoperative pain. Results The "one per mil" epinephrine solution showed an effective hemostatic effect. The tumescent technique resulted in an almost bloodless operation field in the tendon and in the constriction ring syndrome surgeries, minimal bleeding in the flap and contracture release surgeries, and acceptable bleeding in acrosyndactyly surgery. The amount of solution injected ranged from 5.3 to 60 mL. No patient expressed significant postoperative pain. Flap surgeries showed mixed results. One flap was lost, while the others survived. Conclusions Epinephrine 1:1,000,000 in saline solution is a potential replacement for a tourniquet in hand surgery. Further studies are needed to delineate its safety for flap survival.

Burning Rate Characteristics of Solid Propellant at Extremely High Pressure (초고압에서 고체 추진제의 연소속도 특성)

  • Sung, Hong-Gye;Yoo, Ji-Chang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2006
  • Notable are the burning rate characteristics of solid propellant burning at extremely high pressure(10000-20000 psia). The burning rate test using closed bomb shows the discontinuous increment around 4000 psia so that the exponent of burning rate(n) is almost double, from 0.4 to 0.8. The pressure-increasing rate of the test motor is about 300 times as high as that of the motor operating at the conventional pressure, less than 2000 psia, is, therefor the burning rate is augmented about 5-50 times. The performance prediction reflecting the pressure-change-rate effect are fairly comparable with the test data at various test conditions.

3-D CFD Analysis of the CANDU-6 Moderator Circulation Under Nnormal Operating Conditions

  • Yoon, Churl;Rhee, Bo-Wook;Min, Byung-Joo
    • Nuclear Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.559-570
    • /
    • 2004
  • A computational fluid dynamics model for predicting moderator circulation inside the Canada deuterium uranium (CANDU) reactor vessel has been developed to estimate the local subcooling of the moderator in the vicinity of the calandria tubes. The buoyancy effect induced by the internal heating is accounted for by the Boussinesq approximation. The standard $k-{\varepsilon}$ turbulence model with logarithmic wall treatment is applied to predict the turbulent jet flows from the inlet nozzles. The matrix of the calandria tubes in the core region is simplified to a porous media in which the anisotropic hydraulic impedance is modeled using an empirical correlation of pressure loss. The governing equations are solved by DFX-4.4, a commercial CFD code developed by AEA technology. The resultant flow patterns of the constant-z slices containing the inlet nozzles and the outlet port are "mined-type", as observed in the former 2-dimensional experimental investigations. With 103% full power for conservatism, the maximum temperature of the moderator is $82.9^{\circ}C$ at the top of the core region. Considering the hydrostatic pressure change, the minimum subcooling is $24.8^{\circ}C$.

Stress Variation Characteristics of a High-Pressure Hose with Respect to Wire Braid Angle (강선의 편조각도에 따른 고압호스의 응력변화 특성)

  • Kim, H.J.;Koh, S.W.;Kim, B.T.
    • Journal of Power System Engineering
    • /
    • v.9 no.3
    • /
    • pp.71-78
    • /
    • 2005
  • A high-pressure hose includes rebar layers of the synthetic fiber such as nylon or a steel wire to control internal pressure. The hose assembly is manufactured through the swaging process to clamp the hose into the metal fittings. Usually, the hose behavior is affected by the resultant of the longitudinal and circumferential forces produced by the internal pressure. The rebar layers can appear the most ideal rebar effect when they are arranged to the same direction as the resultant force. The braid angle applied in the rebar layers is an important factor in determining ultimate burst pressure and overall hose life. Failure can occur on the contacted parts of a hose with the metal fittings under severe operating conditions such as high pressure and temperature of the inner fluid. In this paper, the mechanical behavior between the hose and the metal fittings during the swaging process and the stress variation characteristics of a high-pressure hose under a constant applied pressure are analyzed with respect to the braid angle of steel wire using the finite element method.

  • PDF

The Characteristic of TEC Power Consumption of Laser Diode Module (레이저다이오드 모듈 냉각용 TEC 소비전력 특성)

  • Lee Jong Jin;Yu Chong Hee;Kang Hyun Seo;Koh Jai Sang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.71-76
    • /
    • 2004
  • The power consumption of TEC for Laser diode cooling was predicted by 3-D FEM simulation and verified by experiment. The operating conditions such as power consumption of Laser diode, set temperature, ambient temperature, resistance of thermal path was considered to estimate the TEC power consumption. Using 3-D FEM simulation, the relation between TEC configuration defined by the pellet dimension and the number and power consumption was investigated for low power consumption scheme. As a result, as the thermal resistance of the pellet increased, the power consumption decreased.

  • PDF

Development of a Plasma Waterjet Scrubber for the Reduction of PFCs (과불화탄소 제거를 위한 플라즈마 워터젯 스크러버 개발)

  • Lee, Chae-Hong;Chun, Young-Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.624-632
    • /
    • 2010
  • Perfluorocarbons (PFCs) are widely used in semiconductor industry. These gases need to be removed efficiently because of their strong absorption of infrared radiation and long atmospheric lifetimes which cause the global warming effect. To destruct $CF_4$, a waterjet gliding arc plasma was designed and manufactured. The highest $CF_4$ destruction showed at waterjet plasma case, compared to plasma discharge only or water scrubber only, respectively. In addition, it could be known that the $CF_4$ destruction should be associated with the electron and OH radicals. The operating conditions such as waterjet flow rate, initial $CF_4$ concentration, total gas flow rate, specific energy input were investigated experimentally using a plasma waterjet scrubber. Through the parametric studies, the highest $CF_4$ destruction of 94.5% was achieved at 0.2% $CF_4$, 2.1 kJ/L SEI, 20 L/min total gas flow rate and 18.5 mL/min waterjet flow rate.