• 제목/요약/키워드: effect of operating conditions

검색결과 811건 처리시간 0.028초

Pilot 규모 석탄 가스화기에서의 탄종별 가스화성능 특성 (Effects of Different Coal Type on Gasification Characteristics)

  • 박세익;이중원;서혜경
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.470-477
    • /
    • 2010
  • The IGCC (Integrated gasification combined cycle) is known for one of the highest efficiency and the lowest emitting coal fueled power generating technologies. As the core technology of this system is the gasifier to make the efficiency and the continuous operation time increase, the research about different coal's gasification has been conducted. Our research group had set-up the coal gasifier for the pilot test to study the effect of different coals-Shenhua and Adaro coal- on gasification characteristics. Gasification conditions like temperature and pressure were controlled at a fixed condition and coal feed rate was also controlled 30 kg/h to retain the constant experimental condition. Through this study we found effects of coal composition and $O_2$/coal ratio on the cold gas efficiency, carbon conversion rate. The compounds of coal like carbon and ash make the performance of gasifier change. And carbon conversion rate was decreased with reduced $O_2$/coal ratio. The optical $O_2$/coal ratio is 0.8 for the highest cold gas efficiency approximately. At those operating conditions, the higher coal has the C/H ratio, the lower syn-gas has the $H_2$/CO ratio.

이차분사노즐 작동 조건 변화에 따른 SITVC 성능해석 (Performance Analysis of SITVC System with Various Secondary Injection Conditions)

  • 배지열;송지운;김태환;조형희;배주찬
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.116-121
    • /
    • 2011
  • SITVC 시스템의 이차분사 노즐 분사 조건 변화에 따른 시스템 성능 변화를 수치적으로 연구하였다. 해석에 사용된 형상은 3차원 종형 수축-팽창 노즐이고 측면에 8개의 이차분사 노즐을 가진다. 노즐 내부 유동은 전압이 70bar이며 300K의 cold flow로 가정하였다. 이차 유동의 유량 변화와 노즐 작동 조건 변화를 고려하였다. 상용코드인 Ansys Fluent v.13을 통해 해석하였고, 난류모델은 Spalart-Allmaras model(1- equation)를 사용하였다. 충격파의 수치적 진동을 막고 충격파의 불연속성을 잘 해석하기 위해 AUSM+ scheme을 사용하였다. Axial thrust, side force, system specific impulse ratio 와 같은 성능 변수를 사용해 시스템 성능을 평가하였다.

  • PDF

야지 자율주행을 위한 환경에 강인한 지형분류 기법 (Robust Terrain Classification Against Environmental Variation for Autonomous Off-road Navigation)

  • 성기열;유준
    • 한국군사과학기술학회지
    • /
    • 제13권5호
    • /
    • pp.894-902
    • /
    • 2010
  • This paper presents a vision-based robust off-road terrain classification method against environmental variation. As a supervised classification algorithm, we applied a neural network classifier using wavelet features extracted from wavelet transform of an image. In order to get over an effect of overall image feature variation, we adopted environment sensors and gathered the training parameters database according to environmental conditions. The robust terrain classification algorithm against environmental variation was implemented by choosing an optimal parameter using environmental information. The proposed algorithm was embedded on a processor board under the VxWorks real-time operating system. The processor board is containing four 1GHz 7448 PowerPC CPUs. In order to implement an optimal software architecture on which a distributed parallel processing is possible, we measured and analyzed the data delivery time between the CPUs. And the performance of the present algorithm was verified, comparing classification results using the real off-road images acquired under various environmental conditions in conformity with applied classifiers and features. Experiments show the robustness of the classification results on any environmental condition.

액체 로켓엔진에서 연소 안정화기구의 적용 효과 (Application of Combustion Stabilization Devices to Liquid Rocket Engine)

  • 손채훈;설우석;이수용;김영목;이대성
    • 한국항공우주학회지
    • /
    • 제31권6호
    • /
    • pp.79-87
    • /
    • 2003
  • 로켓엔진에서 발생하는 고주파 연소 불안정(음향 불안정)을 억제하기 위해 엔진에 적용되는, 배플이나 음향공과 같은 연소 안정화기구를 설계하고 그 효과를 시험을 통해 검증하였다. 먼저, 음향 감쇠 관점에서, 선형 감쇠이론을 토대로 연소 안정화기구를 설계하였으며, 주요 설계인자로서 감쇠인자를 고려하여 여러 연소실에서의 감쇠인자를 수치적으로 계산하였따. 다음으로, 다양한 작동조건에서, 음향공이 장착된 무배플 연소실에서의 연소시험이 수행되었다. 이를 통해 무배플 연소실의 안정성 특성, 주요 유해주파수 및 유해 음향모드 등이 파악되었으며, 동적 안정성 여분이 상당히 작음이 확인되었다. 이는, 무배플 연소실의 연소 안정화에 현재 사양의 음향공의 효과가 미흡함을 입증한다. 배플의 효과를 입증하기 위해 배플장착 연소실에서 연소 안정성 평가시험을 수행하였고, 뚜렷한 연소 안정화 현상을 관측할 수 있었다. 이는 현 설계사양의 배플이 충분한 감쇠 효과를 가짐을 입증한다.

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • 멤브레인
    • /
    • 제1권1호
    • /
    • pp.59-59
    • /
    • 1991
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and CO₂ flow rate CO₂ pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high CO₂ removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

정형보철용 금속이 자기공명영상에 미치는 영향 I (Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I)

  • 김형균;최성대
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

Mitigation of Negative Impedance Instabilities in a DC/DC Buck-Boost Converter with Composite Load

  • Singh, Suresh;Rathore, Nupur;Fulwani, Deepak
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1046-1055
    • /
    • 2016
  • A controller to mitigate the destabilizing effect of constant power load (CPL) is proposed for a DC/DC buck-boost converter. The load profile has been considered to be predominantly of CPL type. The negative incremental resistance of the CPL tends to destabilize the feeder system, which may be an input filter or another DC/DC converter. The proposed sliding mode controller aims to ensure system stability under the dominance of CPL. The effectiveness of the controller has been validated through real-time simulation studies and experiments under various operating conditions. The controller has been demonstrated to be robust with respect to variations in supply voltage and load and capable of mitigating instabilities induced by CPL. Furthermore, the controller has been validated using all possible load profiles, which may arise in modern-day DC-distributed power systems.

열교환기 전열용량이 냉동시스템의 성능에 미치는 영향 (Performance Characteristics with Capacities of Heat Exchangers of a Refrigeration System)

  • 김제봉;김수연;정평석;조경철
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.187-195
    • /
    • 2003
  • The geometric size and the refrigeration capacity of a refrigeration system are strongly dependent on the capacity of heat exchanger, which is one of the key design parameters. In this paper, the effect of the capacities of heat exchangers on the performance of a real refrigeration system operated in a vapor compression cycle was analyzed by the numerical simulation. From the results, the conditions that gave the maximum values of the refrigeration capacity or COP were respectively determined as a function of the capacities of condenser and evaporator under the given ambient and operating condition.

고밀도 수산화니켈 분말의 제조에 관한 연구-I (Fabrication of High-Density Nickel Hydroxide Powder-I)

  • 신동엽;조원일;신치범;조병원;강탁;윤경석
    • 한국표면공학회지
    • /
    • 제28권2호
    • /
    • pp.92-100
    • /
    • 1995
  • To increase the capacity of positive electrode materials for matching the high capacity negative electrode materials in alkaline rechargeable batteries, high-density nickel hydroxide powders were made through a continuous process from nickel sulfate reacted with ammonia and sodium hydroxidc. The effect of operating conditions on structure, shape, size distribution, apparent density and tap density of powders were investigated. Crystal structure of nickel hydroxide powder was hcp according to Bravais Lattice. The increase of mean residence time promoted the growth of (101) plane. The shape of powder was nearly spherical. Their size was in the range of $2~50\mu\textrm{m}$. The size distribution of the powders prepared was narrower than that of commercially obtained nickel hydroxide. Apparent density and tap density were 1.6~1.7g/cc and 2.0~2.1g/cc, respectively.

  • PDF

Experimental Investigation of Heat Transfer Enhancement in a Circular Duct with Circumferential Fins and Circular Disks

  • Taebeom Seo;Byun, Sang-Won;Jung, Myoung-Ryol
    • Journal of Mechanical Science and Technology
    • /
    • 제14권12호
    • /
    • pp.1421-1428
    • /
    • 2000
  • The characteristics of heat transfer and pressure drop for fully developed turbulent flow in a tube with circumferential fins and circular were experimentally studied. The various spacing and sizes of circumferential fins and circular disks were selected as design parameters, while the effects of these parameters on heat transfer enhancement and pressure drop were investigated. In order to quantify the effect of heat transfer enhancement and the increase of pressure drop due to the fins and disks in a tube, the Nusselt numbers and the friction factors for various configurations and operating conditions were compared to those for a corresponding smooth tube. The results showed that the heat transfer rate was significantly enhanced by increasing the height of circumferential fins and decreasing the pitch of circumferential fins. On the other hand, the influence of the disk size and the fin-disk spacing were not significant. Based on the experimental results, a correlation for estimating the Nusselt number was suggested.

  • PDF