• 제목/요약/키워드: effect of operating conditions

검색결과 811건 처리시간 0.03초

엔진의 착화실패가 탄성지지계의 동적거동에 미치는 영향 (The Effects of Engine's Misfiring Condition on the Dynamic Behaviour of Resilient Mounting Systems)

  • 장민오;손석훈;김의간;김의간
    • 소음진동
    • /
    • 제6권4호
    • /
    • pp.503-511
    • /
    • 1996
  • There is a tendency of using the resilient mounting system to control the structure born noise transimitted from a engine of which weight is comparatively light and of which speed is comparatively high. According to recent reports, the resilient mounting system is applied to control the vibration of a engine running up to 300 - 400 R.P.M.. Furthermore, the resilient system is also used to the ships such as marine exploring ships, fishing boats, and military vessels. It is not desirous to apply the results for the resilient mounting systems of automobile engines to the controls of the vibrations of marine engines. Marine engines are worked under the idle speed in port and are operated up to the maximum contineous revolution at sea(running up condition). And marine engines are usually worked in inevitable conditions such as a misfire and a cut-off cylinder operating condition. Concerning the above running conditions, a resilient mounting system should be designed in the case of marine engines. In this paper, we studied the effect of engine's misfire on the resilient mounting systems. And the influences of design parameters, such as dynamic characteristics and fitting angles of resilient rubber mountings, were also investigated respectively on the single and double resilient mounting systems.

  • PDF

스팀분사를 고려한 SOFC/GT 하이브리드 시스템의 설계 성능 비교 분석 (Design Performance Analysis of Solid Oxide Fuel Cell / Gas Turbine Hybrid Systems Considering Steam Injection)

  • 박성구;김동섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3224-3229
    • /
    • 2007
  • This study aims to analyse the influence of steam injection on the performance of hybrid systems combining a solid oxide fuel cell and a gas turbine. The steam is generated by recovering heat from the exhaust gas. Two system configurations, with difference being the operating pressure of the SOFC, are examined and effects of steam injection on performances of the two systems are compared. Two representative gas turbine pressure ratios are simulated and a wide range of both the fuel cell temperature and the turbine inlet temperature is examined. Without steam injection, the pressurized system generally exhibits better system efficiency than the ambient pressure system. Steam injection increases system power capacity for all design cases. However, its effect on system efficiency varies much depending on design conditions. The pressurized system hardly takes advantage of the steam injection in terms of the system efficiency. On the other hand, steam injection contributes to the efficiency improvement of the ambient pressure system in some design conditions. A higher pressure ratio provides a better chance of efficiency increase due to steam injection.

  • PDF

아임계수를 이용한 사과 과피 플라보노이드의 효율적 추출 및 항산화 활성 평가 (Efficient Flavonoid Extraction from Apple Peel by Subcritical Water and Estimation of Antioxidant Activity)

  • 최찬익;유서연;정명수
    • 한국식품영양학회지
    • /
    • 제24권3호
    • /
    • pp.458-463
    • /
    • 2011
  • The effect of subcritical water for the extraction of total polyphenols and flavonoids from apple peel was investigated, and then the antioxidant activity of the extracts was estimated. Maximum yields of total polyphenolic compounds($36.4{\pm}1.9mg$ quercetin equivalent(QE)/g dried material) and flavonoids($9.9{\pm}0.8mg$ QE/g dried material) were obtained by subcritical water extraction(SWE) with operating conditions of $190^{\circ}C$, 1,300 psi, and 20 min. Furthermore, the highest antioxidant activity($76.1{\pm}1.1%$) was observed in the extract obtained from SWE using the same conditions. The flavonoids from the SWE of apple peel were compared to three conventional extraction methods in terms of their extraction efficiency and antioxidant activity. The SWE was significantly more effective than hot water ($90^{\circ}C$), methanol, and ethanol extraction for flavonoid yield by 4.7-, 2.2-, and 1.3-fold, respectively, and for antioxidant activity by 11.0-, 4.9, and 2.8-fold, respectively.

3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구 (A Study on Performance Analysis of 3kW Grid-Connected PV Systems)

  • 소정훈;최주엽;유권종;정영석;최재호
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.

정수처리시 잔류알루미늄 농도를 최소화하기 위한 영향인자 고찰 (A Study on the Factors to Minimize the Residual Aluminum in Filtered Water)

  • 고영송;우달식;남상호
    • 한국환경보건학회지
    • /
    • 제19권2호
    • /
    • pp.1-9
    • /
    • 1993
  • In public water supply systems, Alum and/or PAC being used as a coagulant. It is well known that their use increased frequently the concentration of residual aluminum in filtered water upon operating conditions. This study was conducted to find the optimum conditions that both the concentration of residual aluminum and turbidity are minimized by changing such factors as pH, temperature, alum dosage, mixing rate, alkalinity and hardness. The results can be summarized as follows: The pH values for the minimum concentration of residual aluminum and turbidity as a given experimental condition were found at pH 6 and pH 7 respectively, the apparent clarity was best at pH 8. The floc settling rate was the greatest at pH 6.5, but the turbidity was high at the same condition. The more alum dosage, the higher the concentration of residual aluminum. However the alum dosage less than 15 mg/l tend to decrease in turbidity. Restabilization and enmeshment occurred near 15 mg/l and 20 mg/l of alum dose respectively. With the increase of mixing rate (rapid and slow), the concentration of residual aluminum and turbidity are increased and the same trend was found in increment of mixing time. At low water temperature, the concentration of residual aluminum was decreased, but turbidity was increased. It was confirmed that alkalinity had an effect on the coagulation efficiency, but hardness did not.

  • PDF

Sensitivity studies in spent fuel pool criticality safety analysis for APR-1400 nuclear power plants

  • Al Awad, Abdulrahman S.;Habashy, Abdalla;Metwally, Walid A.
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.709-716
    • /
    • 2018
  • A criticality safety analysis was performed for the APR-1400 spent fuel pool region-II to ensure the safe storage of spent fuel, with credit taken for depletion and in-rack neutron absorbers (Metamic panels). PLUS7 fuel assembly was modeled using TRITON-NEWT of SCALE-6.1. The burnup-dependent cross-section library was generated under limiting core-operating conditions with 5%-w U-235 initial enrichment. MCNP5 was used to evaluate the neutron multiplication factor in an infinite array of rack cells with the axially nonuniformly burnt PLUS7 assemblies under normal, abnormal, and accident conditions; including all biases and uncertainties. The main purpose of this study is to investigate reactivity variations due to the critical depletion and reactor operation parameters. The approach, assumptions, and modeling methods were verified by analyzing the contents of the most important fissile and the associated reactivity effects. The Nuclear Regulatory Commission (NRC) guidance on k-eff being less than 1.0 for spent fuel pools filled with unborated water was the main criterion used in this study. It was found that assemblies with 49.0 GWd/MTU and 5.0 w/o U-235 initial enrichment loaded in Region-II satisfy this criterion. Moreover, it was found that the end effect resulted in a positive bias, thus ensuring its consideration.

자동차용 CO2 에어컨 시스템의 성능 특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics of a CO2 Air-conditioning System for Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제23권1호
    • /
    • pp.18-24
    • /
    • 2015
  • In this study, a $CO_2$ air-conditioning system was investigated with different types of electrically driven compressors, parallel flow type gas cooler, four-pass type evaporator, internal heat exchanger integrated with accumulator, and electric expansion valve. The experimental study was conducted under various operating conditions (ie., different rotational compressor speeds, air inlet temperatures and air velocity coming into heat exchangers). The experimental results showed the cooling capacity was 3.5kW at $35^{\circ}C$ ambient temperature when the vehicle was idle (ie., the worst condition for cooling off the gas cooler). In terms of performance effect of the compressor, the e-RP model had a slightly better cooling capacity and coefficient of performance than the e-GR model under the same test conditions. An experimental equation for optimum cooling-performance control was also suggested based on the results. A high-pressure control algorithm for the super critical cycle was determined to achieve both maximum cooling performance and efficient energy consumption. The results from the experimental equation coincided with those of previous experimental studies.

Utilization of Waste Aluminium Foil as a Sacrificial Electrode for the Treatment of Wastewater

  • Perumalsamy, Rajagopal;Kumaran, Chithra;Rajamanickam, Vaishali
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.92-100
    • /
    • 2021
  • In this study, the use of waste food grade aluminium foil and mild steel as a sacrificial electrode in an electrocoagulation system was developed to remove reactive red 111 from wastewater. The effect of different parameters like pH, current density, electrode material, and different electrode configurations was investigated. Optimum operating conditions for maximum COD removal were determined as, 6 mA/㎠ current density and 30 min at 5 pH for aluminium foil and 7 pH for mild steel. Maximum COD reduction obtained at optimum conditions using monopolar 4 electrodes, monopolar 2 electrodes and bipolar electrode configuration were 96.5%, 89.3%, and 90.2% for Mild steel as a sacrificial electrode and 92.1%, 84.2%, and 88.6% for aluminium foil as a sacrificial electrode. The consumption of electrode and energy for both the electrodes of different configurations were calculated and compared. Using batch experimental data, a continuous-flow reactor was developed. Sludge analysis using Fourier Transform Infra-Red Spectroscopy (FTIR) analysis was done. Different adsorption kinetic models and isotherms were developed and it was found that pseudo second-order model and Langmuir isotherm fit best with the experimental data obtained.

13K Chemical Tanker의 기관 제어 불능상태 IMO 2세대 안정성 평가에 관한 실험적 연구 (An Experimental Study on IMO 2nd Generation Stability Assessment in Dead Ship Condition of 13K Chemical Tanker)

  • 이상범;문병영
    • 대한조선학회논문집
    • /
    • 제59권2호
    • /
    • pp.89-95
    • /
    • 2022
  • The stability of the existing ships has been evaluated through numerical calculations in the steady-state, but recently the IMO proposed a new stability assessment criteria that the stability is evaluated in the state in which environmental loads from such as waves and wind act like the loads under actual ship operating conditions. In this study, IMO 2nd generation stability assessment method and procedure were summarized for the dead ship condition, and Direct Stability Assessment (DSA) was performed on 13K chemical tanker through basin model test. The model test is performed in the ocean engineering basin to implement wave and wind loads, and environmental conditions for waves were set height and period of the incident wave, considering the regular wave and wind generation range reproducible in the ocean engineering basin. In addition, to consider the effect of wind speed, the Beaufort Scale for wind speed was applied in the model test.

Synthesis and Characterization of Calcium Derivative Combined with High-Surface-Area Activated Carbon Composites for Fine Toxic Gas Removal

  • Areerob, Yonrapach;Nguyen, Dinh Cung Tien;Dowla, Biswas Md Rokon;Kim, Hyuk;Cha, Je-Woo;Oh, Won-Chun
    • 한국세라믹학회지
    • /
    • 제55권5호
    • /
    • pp.473-479
    • /
    • 2018
  • Highly toxic gases such as hydrogen sulfide ($H_2S$), carbon dioxide ($CO_2$), and ammonia ($NH_3$) are generated by both nature and human activities and affect human health. In this research, activated carbon combined with $Ca(OH)_2$ and $CaCO_3$ (AC-CO and AC-CC, respectively) were fabricated and applied in absorbing toxic gases from air pollutants. Activated charcoal powder was compressed in the form of pellets and used in the designated conditions. The optimum operating conditions and material properties, such as adsorption capacity, effect of weight ratio of the mixture, and hardness, have been investigated after combining with the calcium derivative. The good performance exhibited in this study suggests that this material is expected to be an effective and economically viable adsorbent for $NH_3$, $CO_2$, and $H_2S$ removal from the air system.