• 제목/요약/키워드: eddy current distribution

검색결과 128건 처리시간 0.032초

Numerical characterization of downburst wind field at WindEEE dome

  • Ibrahim, Ibrahim;Aboshosha, Haitham;El Damatty, Ashraf
    • Wind and Structures
    • /
    • 제30권3호
    • /
    • pp.231-243
    • /
    • 2020
  • Downbursts are acknowledged for being a major loading hazard for horizontally-extending structures like transmission line systems. With these structures being inherently flexible, it is important to characterize the turbulence associated with the wind flow of downburst events being essential to quantify dynamic excitations on structures. Accordingly, the current study numerically characterizes the downburst wind field of open terrain simulated at the Wind Engineering, Energy and Environment (WindEEE) dome testing facility at The University of Western Ontario in Canada through a high-resolution large eddy simulation (LES). The study validates the numerical simulation considering both the mean and the turbulent components of the flow. It then provides a detailed visual description of the flow at WindEEE through the capabilities enabled by LES to identify the key factors affecting the flow. The study also presents the spatial distribution of turbulence intensities and length scales computed from the numerical model and compares them with previous values reported in the literature. The comparison shows the ability of the downburst simulated at WindEEE to reproduce turbulence characteristics similar to those reported from field measurements. The study also indicates that downburst turbulence is well-correlated circumferentially which imposes high correlated loads on horizontally-distributed structures such as transmission lines.

보염기에 의해 안정되는 난류확산화염의 연소특성에 관한 연구 (A Study on the Combustion Characteristics of Turbulent Diffusion Flame Stabilized by Bluff Body)

  • 안진근;송규근
    • 한국연소학회지
    • /
    • 제3권1호
    • /
    • pp.71-78
    • /
    • 1998
  • The flame stabilization and the combustion characteristics of diffusion flame formed in the wake of a cylindrical bluff body with fuel injection are studied. With the turbulence generator, the flame stability limits and ion currents were measured and analyzed. The results from this experimental study are summarized as follows. The region with highest average value of ion currents in the middle of flame is moved to the upstream side by the turbulent components of main stream. The flame mass with partially active reaction is moved fast for uniform flow and turbulence generator G3, but the flame mass with relatively slow reaction is moved slowly for turbulence generator G1. If the turbulence generator with strong turbulent component is installed, the turbulent time scale is increased with movement from main stream side to recirculation zone as well as the flame stability limits is deteriorated. Though the special dominant frequency is not appeared in the eddy which exists in flame, high frequency characteristics are appeared in uniform flow and turbulence generator G3, and low frequency characteristics are appeared in uniform flow, turbulence generator G3 and G1.

  • PDF

KSTAR 진공용기 열 및 전자기력 하중에 의한 응력해석 (Stress analysis of the KSTAR vacuum vessel under thermal and electromagnetic loads)

  • 조승연;김종배;허남일;임기학;사정우;유인근;김윤춘;도철진;권면
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.325-330
    • /
    • 2001
  • One of the principal components of the KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak structure is the vacuum vessel, which acts as the high vacuum boundary for the plasma and also provides the structural support for internal components. Hyundai Heavy Industries Inc. has performed the engineering design of the vacuum vessel. Here the overall configuration of the KSTAR vacuum vessel was briefly described and then the design methodology and the analysis results were presented. The vacuum vessel consists of double walls, several ports, leaf spring style supports. Double walls are separated by reinforcing ribs and filled with baking/shielding water. The overall external dimensions of the main body are 3.39 m high, 1.11 m inner radius, 2.99 m outer radius, and made of SA240-316LN. The vacuum vessel was designed to be capable of achieving the base pressure of $1\times10^{-8}$ Torr, and also to be structurally capable of sustaining the vacuum pressure, the electromagnetic and thermal loads during plasma disruption and bakeout, respectively. The vacuum vessel will be baked out maximum $150^{\circ}C$ by hot pressurized water through the channels formed between double walls and the reinforcing ribs. A 3-D temperature distribution and the resulting thermal loads in the vessel were calculated during bakeout. It was found that the vacuum vessel and its supports were structurally rigid based on the thermal stress analysis. The maximum electromagnetic loads on the vacuum vessel induced by eddy and halo currents resulting from the engineering plasma radial and vertical disruption scenarios have been estimated. The stress analyses have been performed based on these electromagnetic loads and the resulting stresses at he critical locations of the vacuum vessel were within the allowable stresses.

  • PDF

초고압 전력기기의 온도상승 예측 (Prediction of Temperature Rise in Power Appratus)

  • 김승욱;박정홍;한성진;이병윤;박경엽;송원표;김정배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.113-115
    • /
    • 2001
  • In order to design the power appratus such ac bus bar, the current carrying ampacity should be determined, Since it is limited by maxium operating temperature, it is very important to predict temperature-rise on it. The main causes to raise temperature are joule's loss in the current carrying conductor and induced circulating and eddy current in the tank. The heat transfer is divided into convection and radiation on boundary, determining convection heat transfer coefficient is not easy. This paper propose a new technique that can be used to estimate the temperature rise in the extra high voltage bus bar. The heat transfer coefficient is analytically calculated by applying Nusselt Number depending on temperature as well as model geometry. The analytic method which use heat transfer coefficient is coupled with finite element method. The temperature distribution in the bus bar by the proposed method shows good agreement with experimental data.

  • PDF

한국표준형 원전 증기발생기 전열관 축방향 ODSCC 발생원인 분석 (Root Cause Analysis of Axial ODSCC of Steam Generators Tubes of OPR1000)

  • 김홍덕;박수기;임창재;정한섭
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.83-88
    • /
    • 2010
  • Domestic nuclear steam generators with Alloy 600 HTMA tubes have experienced axial cracking at eggcrate tube support plates(TSPs). The axial stress corrosion cracks were observed at the crevice between outside of tubes and eggcrate TSPs. The root cause of axial cracking was investigated by thermal hydraulic analysis and sludge distribution diagnosis. It is suggested that deposition of sludge at eggcrate TSPs could increase the outside surface temperature of tube and promote the enrichment of impurities at crevice, and thus accelerate cracking. Additionally strategy for reducing the sludge ingress to steam generators is discussed.

  • PDF

유압펌프용 실린더 블록의 윤활 및 동특성 해석 (Analysis of Lubrication and Dynamic Characteristics of a Cylinder Block for Hydraulic Pump)

  • 안성용;임윤철;홍예선
    • Tribology and Lubricants
    • /
    • 제20권4호
    • /
    • pp.209-217
    • /
    • 2004
  • Lubrication characteristics between a cylinder block and a valve plate for high speed bent-axis type hydraulic pump play an important role in volumetric efficiency and durability of pump. In this paper, a finite element method is presented for the computation of the pressure distribution between a cylinder block and a valve plate for high speed bent-axis type hydraulic pump. Also, a Runge-Kutta method is applied to simulate the cylinder block dynamics of three-degrees of freedom motion. From the results of computation, we can draw two major conclusions. One is related to the fluid film characteristics between a cylinder block and a valve plate and the other is related to the average leakage that is determined by the pressure gradient and the clearance near the discharge port. The numerical results of cylinder block dynamics were compared with the experimental results using eddy-current type gap sensors those are fixed at a pump housing.

3상 유도 전동기에서의 열손실 사상법을 이용한 열전달-전자기장 연계 수치 해석 모델 개발 (The Model Development of Coupled Thermo-Electromagnetic Analysis in Three-phase Induction Motors by using Heat loss Mapping Method)

  • 김동희;김치원;정혜미;이주;엄석기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.788-789
    • /
    • 2011
  • A comprehensive thermo-electromagnetic model has been developed to estimate temperature and electromagnetic distribution in an three-phase induction motor under steady state operation. Electromagnetic modeling enables us to predict thermal dissipation rates by eddy-current loss and copper loss in induction motors. Non-uniform temperature distributions are investigated to account for the strong effect of local temperature build-up on the motor performance and expected life-span. For more accurate thermal modeling purpose, Heat loss mapping method, which is matched up with electromagnetic losses and volumetric heat source, is developed and performed analysis. Heat loss mapping method can be greatly used as a design or diagnostic tool for three-phase induction motors with complex structural electromagnetic fields.

  • PDF

등가회로 법을 이용한 Thomson Coil Actuator 특성 해석 (A Numerically Efficient Performance Analysis of Thomson Coil Actuator of Arc Eliminators Using Equivalent Circuit Method)

  • 리웨이;루지앙;정영우;고창섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.772_773
    • /
    • 2009
  • A numerically efficient performance analysis method for Thomson coil actuator of an arc eliminator is developed by transferring the problem to an equivalent circuit model considering the distribution of eddy current in conducting plate. Through a numerical analysis, the developed method is proven to give a solution, with only 1.3% of computing time, as accurate as finite element method. The developed method is testified by comparing with FEM calculation and experiment results.

  • PDF

Calculation of Temperature Rise in Gas Insulated Busbar by Coupled Magneto-Thermal-Fluid Analysis

  • Kim, Hong-Kyu;Oh, Yeon-Ho;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.510-514
    • /
    • 2009
  • This paper presents the coupled analysis method to calculate the temperature rise in a gas insulated busbar (GIB). Harmonic eddy current analysis is carried out and the power losses are calculated in the conductor and enclosure tank. Two methods are presented to analyze the temperature distribution in the conductor and tank. One is to solve the thermal conduction problem with the equivalent natural convection coefficient and is applied to a single phase GIB. The other is to employ the computational fluid dynamics (CFD) tool which directly solves the thermal-fluid equations and is applied to a three-phase GIB. The accuracy of both methods is verified by the comparison of the measured and calculated temperature in a single phase and three-phase GIB.

와전류탐상과 유한요소해석을 이용한 Carbon/epoxy 튜브의 결함 평가

  • 김철웅;이정순;엄태건;송일;구상모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.75-75
    • /
    • 2004
  • Carbon/epoxy는 기존의 금속재료에 비해 피로강도 및 기계적 특성이 매우 우수하다. 따라서 최근 튜브형태의 Carbon/epoxy 활용방안이 부각되고 있다. 그러나 Carbon/epoxy는 탄소재료의 특성상 고압, 충격 및 부식에 매우 취약하다. 또한, 장기간 고압피로 및 크리프에 노출될 경우, 금속재료에서는 관찰할 수 없는 층간분리(delamination)가 발생된다. 이러한 층간분리는 섬유방향과 평행하게 진전될 때 급격한 파손을 야기하므로 층간분리에 대한 메커니즘을 이해하고 그 방지책을 강구하는 것은 매우 중요하다.(중략)

  • PDF