Performance improvement of Classification of Steam Generator Tube Defects in Nuclear Power Plant Using Neural Network (신경회로망을 이용한 원전SG 세관 결함패턴 분류성능 향상기법)

  • Jo, Nam-Hoon;Han, Ki-Won;Song, Sung-Jin;Lee, Hyang-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1224-1230
    • /
    • 2007
  • In this paper, we study the classification of defects at steam generator tube in nuclear power plant using eddy current testing (ECT). We consider 4 defect patterns of SG tube: I-In type, I-Out type, V-In type, and V-Out type. Through numerical analysis program based on finite element modeling, 400 ECT signals are generated by varying width and depth of each defect type. In order to improve the classification performance, we propose new feature extraction technique. After extracting new features from the generated ECT signals, multi-layer perceptron is used to classify the defect patterns. Through the computer simulation study, it is shown that the proposed method achieves 100% classification success rate while the previous method yields 91% success rate.

Electroconvulsive Therapy in Major Depressive Disorder (주요우울장애에서의 전기경련요법)

  • Lee, Hwa-Young;Kang, Rhee-Hun;Lee, Min-Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.2
    • /
    • pp.75-82
    • /
    • 2008
  • Major depressive disorder(MDD) is one of the most common diseases with serious health consequences such as increased morbidity, disability, and mortality. Electroconvulsive therapy(ECT) has been used as a treatment for mental disorder since the 1930s. A growing number of recent publications support the conclusions that ECT is an effective and safe treatment for depressed patients. Dosing strategies, frequency, safety, side effects and efficacy of ECT in MDD will be considered. ECT may be an alternative to treatment with antidepressants.

  • PDF

Numerical Analysis Methods for Eddy Current Testing for Heat Exchanger Tube with Axi-symmetric Defects (열교환기 전열관의 결함에 대한 와전류 탐상 수치해석방법)

  • Kim, Chang-Wook;Seo, Jang-Won;Kim, Shin;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.831-833
    • /
    • 2000
  • In this paper, a numerical analysis algorithm of eddy current testing(ECT) for heat exchanger tube with axi-symmetric defects using finite element method(FEM) is presented. In the ECT FEM analysis, we used trianglular and rectangular elements for exact signal of ECT for variable shape of defects. This paper presents a systematic and efficient numerical analysis algorithm for ECT. We employ the LU decomposition and Cholesky method for solving the system matrix. This numerical analysis algorithm is effectively applied to heat exchanger tube with defects.

  • PDF

Image reconstruction in electrical capacitance tomography based on modified generalized Landweber method (수정된 generalized Landweber 방법을 이용한 ECT 영상 복원)

  • Lee Seong-Hun;Jang Jae-Duck;Kim Yong-Sung;Kim Kyung-Youn;Choi Bong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.5 s.311
    • /
    • pp.68-79
    • /
    • 2006
  • Electrical capacitance tomography (ECT) is a non-invasive imaging reconstruction technique that aims at visualization of cross sectional permittivity distribution of dielectric object based on the measured capacitance. There are lots of iterative image reconstruction methods to accelerate convergence rate and enhance quality of reconstructed image, Among them iterative Landweber method is one of the widely used reconstruction algorithm in En. In this paper, modified generalized Landweber method is proposed to accelerate convergence rate. In doing so, acceleration term is considered to the generalized Landweber method with shaping matrix and an optimal step length is determined analytically. Extensive computer simulations are provided to illustrate the reconstruction performance of the proposed algorithm.

Literature review on the experimental method and interpretation of the edge chipping test (ECT) (Edge chipping test (ECT)의 실험방법과 해석에 관한 문헌고찰)

  • Song, Min-Gyu;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.9-18
    • /
    • 2022
  • In vitro studies are essential to predict the clinical performance of ceramic widely used as restorative materials. Traditional experiments such as fracture toughness and flexural strength have been used to evaluate the properties of brittle ceramics. However, these experiments have a limitation that the load conditions, failure patterns, and load values at which failure occurs are not similar to human occlusal force ranges or clinical failures. On the other hand, the edge chipping test (ECT), which was recently introduced to study chipping fracture of ceramics, has similar failure patterns to clinical trials. In addition, the failure loads from ECT were similar to human occlusal force. ECT can be usefully used in the study of ceramic properties. In this literature review, a more clinically meaningful experimental study of ceramics by examining the meaning and limitations of traditional ceramic failure tests and comparing them with ECT.

Preliminary Analysis of Several Storm Events by using the ECT data onboard Van Allen Probes

  • Choi, Eunjin;Hwang, Junga;Kim, Hang-Pyo;Kim, Kyoung-Chan;Park, Young-Deuk;Min, Kyoung-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.95.2-95.2
    • /
    • 2013
  • The Van Allen Probes were designed to study the Earth's radiation belts on various scales of space and time. The identical two spacecrafts going nearly eccentric orbits lap each other several times over the course of the mission and each probe carries five instrument suites to address the science objectives on the radiation belt. Since Van Allen Probes launched on August 30, 2012, the probes detecte several storm events up to now. To understand the particle acceleration and loss mechanism in the radiation belt, we first focus on the energetic electrons' dynamics detected by ECT (Energetic Particle, Composition, and Thermal Plasma Suite). ECT measures near-Earth space's radiation particles covering the full electron and ion spectra from ~ eV to 10's of MeV with sufficient energy resolution. In this paper, we present the preliminary results of the recent several storm events using electron data from ECT(MagEIS and REPT).

  • PDF

Field Feasibility Study of an Eddy Current Testing System for Steam Generator Tubes of Nuclear Power Plant (원전 증기발생기 와전류검사 시스템 현장적용 연구)

  • Moon, Gyoon-Young;Lee, Tae-Hun;Kim, In-Chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2015
  • Steam generator is one of the most important component of nuclear power plant, and it's integrity and reliability are to be assured to high level by pre-service inspection and in-service inspection. To improve the reliability of steam generator heat exchanger tubes and to secure the management of nuclear power plant safely, KHNP CRI recently has developed eddy current testing system for steam generator. KHNP CRI have performed a series of experimental verification and field application to confirm the performance of the developed ECT system in accordance with ASME Code requirements. The ECT system consists of a remote data acquisition unit, an ECT signal acquisition and analysis software, a water chamber robot controller and a probe push-puller. In this paper, we will details of the developed ECT system and the software and their experimental performance. And also we will report the field applying performance and the issues for further steps.

An Experimental Study on the Anticonvulsive Effects of Jisungbomuyngtan (지성보명단(至聖保命丹)의 항경련(抗痙攣) 작용에 관한 실험적 연구)

  • Lee, Hee-Sung;Kim, Deog-Kon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Objectives In order to investigate the anticonvulsive effects of Jisungbomuyngtan, the experiments were done in mice. Methods After solid extracts of Jisungbomuyngtan was orally administered to mice, four types of convulsion were induced in mice by ECT, strychnine, picrotoxin, caffein. Each of the time to convulsion and death was measured. Results 1. The solid extracts of Jisungbomuyngtan showed a remarkable effect in delaying the onset of convulsion induced by ECT 2. In case of convulsion induced by strychnine, the solid extracts of Jisungbomuyngtan revealed a slight, but not statistically significant effect. 3. Considerable prolongation of time to death was observed in convulsion induced by picrotoxin due to the anticonvulsive effect of Jisungbomuyngtan. 4. The anticonvulsive effect of Jisungbomuyngtan was not found in convulsion induced by caffein. Conclusions Jisungbomuyngtan effect remarkably in delaying the onset of convulsion induced by ECT. But slightly effect by strychnine. And Jisungbomuyngtan effect in prolonging time to death in convulsion induced by picrotoxin, but not found in convulsion induced by caffein.

  • PDF

Detection of Foreign Objects Using Bobbin Probe in Eddy Current Test (이물질에 대한 ECT Bobbin Probe 검출 감도)

  • Jung, Hee-Sung;Kweon, Young-Ho;Lee, Dong-Ha;Shin, Wook-Jo;Yim, Chan-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.295-299
    • /
    • 2016
  • Residual foreign objects at the secondary side (top of the tubesheet and tube support plates) of a steam generator are likely to cause a leak by causing wear in the tube. The extent of wear is significantly affected by the material, shape, and size of the foreign object, and the corrosion properties of the tube. The presence of foreign objects at the top of the tubesheet and tube support plates has been identified using remote visual inspection methods such as the foreign object search and retrieval and eddy current test (ECT). The detection of the residual foreign object at the secondary side of a steam generator has limitations that depend on the material properties and the condition of contact with the tube. In this study, which is vertical and horizontal from the upper tubesheet, the corresponding bobbin ECT signals were collected and analyzed to measure its ability to detect foreign objects.