• Title/Summary/Keyword: ect

Search Result 424, Processing Time 0.03 seconds

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

콘텐츠라인 게임컨벤션 2005

  • Beom, Won-Taek
    • Digital Contents
    • /
    • no.9 s.148
    • /
    • pp.102-103
    • /
    • 2005
  • 지난달 중순 독일 라이프찌히에서 열린 신생 게임 전시회 게임컨벤션(Game Convention)이 국산 게임의 유럽진출 교두보로 부 상했다. 이 전시회는 미국 E3, 일본 도쿄게임쇼(TGS)와 함께 세계 3대 게임쇼로 불리던 영국의 ECTS가 올해부터 폐지되자, 이 공백을 메울 대안으로 각광을 받았다. 올해 4회째인 게임컨벤션은 짧은 연륜에도 불구하고 지난해 E3와 TGS에 맞먹는 10만 5,000명의 관람객이 몰렸다.

  • PDF

A Basic Study on Eddy Current Testing of End-Cap Welds (봉단 용접부 와전류탐상의 기초적인 연구)

  • Suh, D.M.;Sim, K.S.;Kwon, W.J.;Kim, J.H.;Park, C.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 1998
  • In nuclear fuel manufacturing process, end-closure welding has long been recognized as requiring very high integrity. In this basic study, ECT(eddy current testing) method for end-closure welding has been developed to detect end cap weld discontinuities for nuclear fuel safety. In order to improve the inspection reliability, the maximum scanning speed and the maximum frequency is investigated for end-closure welding inspection. The bandpass filter(0-250Hz) is used for removing noise effects. This study shows that ECT method is effective and sensitive for the detection of small defect(0.35mm diameter).

  • PDF

The Study of Interference Cancellation between DSRC and ETC with Adaptive Array Antenna (적응 배열 안테나를 이용한 DSRC와 ETC 상호간 간섭 제거에 관한 연구)

  • 정재승;이병섭
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1147-1155
    • /
    • 2000
  • The installation of wireless communication system for various services of ITS at 5.8 GHz generates mutual interference. The representative example, the sharing of frequency between DSRC system and ETC system is a cause of communication error or disturbance both sides or one side owing to mutual interference. As a solution, a Shield Plate, Antenna Directionality, Power Control is proposed, but these are not perfect solution, because a RSU doesn't have the information of position of interferer. This paper applies an adaptive array antenna which makes a gain for desired users, makes a null for interferer, to up-link, down-link of DSRC and ETC system. The analysis of BER performance shows the effect of reduced interference about 20 dB.

  • PDF

Bibliographic Studies of Depilation (탈모(脫毛)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Jang, Hae-Young;Choi, Kwan-Ho;Kim, Sung-Hyun;Kwon, Ki-Rok;Kim, Byung-Woo
    • Journal of Pharmacopuncture
    • /
    • v.5 no.2
    • /
    • pp.92-108
    • /
    • 2002
  • According to the bibliographic studies of Depilation, the following conditions were made after literary studies.; 1. According to the period, The depilation have been named variously, for example, Balta(髮墮), Balgu(髮去), Balrak(髮落), Mobal(毛拔), Yupung(油風), Dokchang(禿瘡), Guijidu(鬼?頭), Dokban(禿班), etc. 2. The cause of depilation was deficiency of kidney(腎虛), defciency of Qi of the lung(肺氣虛), excessive heat of blood system(血熱), deficiency of Qi and blood system(氣血虛), deficiency of blood system(血虛), and endogenouse cause of, etc. 3. The depilation is meaning fallen hair in head. There are multiform type in the symptoms of depilation; round shape, ellipse type & bald head. 4. The herbal treatment was used Yukmijihwaghwan(六味地黃丸), Palmihwan(八味丸), Singihwan(腎氣丸), Hwangigunjungtang(黃耆建中湯), Samultang(四物湯), ect. and external herbal reatment was Sineungyangjindan(神應養鎭丹), Bangpungtongsungsan(防風通聖散), ect.

Evaluation of the Probability of Detection Surface for ODSCC in Steam Generator Tubes Using Multivariate Logistic Regression (다변량 로지스틱 회귀분석을 이용한 증기발생기 전열관 ODSCC의 POD곡면 분석)

  • Lee, Jae-Bong;Park, Jai-Hak;Kim, Hong-Deok;Chung, Han-Sub
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.250-255
    • /
    • 2007
  • Steam generator tubes play an important role in safety because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear power plant. For this reason, the integrity of the tubes is essential in minimizing the leakage possibility of radioactive water. The integrity of the tubes is evaluated based on NDE (non-destructive evaluation) inspection results. Especially ECT (eddy current test) method is usually used for detecting the flaws in steam generator tubes. However, detection capacity of the NDE is not perfect and all of the "real flaws" which actually existing in steam generator tunes is not known by NDE results. Therefore reliability of NDE system is one of the essential parts in assessing the integrity of steam generators. In this study POD (probability of detection) of ECT system for ODSCC in steam generator tubes is evaluated using multivariate logistic regression. The cracked tube specimens are made using the withdrawn steam generator tubes. Therefore the cracks are not artificial but real. Using the multivariate logistic regression method, continuous POD surfaces are evaluated from hit (detection) and miss (no detection) binary data obtained from destructive and non-destructive evaluation of the cracked tubes. Length and depth of cracks are considered in multivariate logistic regression and their effects on detection capacity are evaluated.

  • PDF

Ectopic Cervical Thymoma: A Case Report and Review

  • Park, Hyun Oh;Kim, Sung Hwan;Moon, Seong Ho;Yang, Jun Ho;Kang, Dong Hoon;Lee, Jeong Hee
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.312-315
    • /
    • 2017
  • In the embryo, the thymus originates from the third and fourth pharyngeal pouches and migrates from the superior neck to the mediastinum. Ectopic cervical thymoma (ECT) is an extremely rare tumor that originates from ectopic tissue, and is caused by the aberrant migration of the embryonic thymus. Our patient was a 30-year-old woman who had a nodular lesion in the neck for several years. Ultrasonography and computed tomography were performed. She underwent surgery, and a histological examination resulted in a diagnosis of type AB thymoma. Herein, we report a case of ECT that was resected through a transcervical approach.

A Study on the Structure of Neural Network for Predicting Defect Size of Steam Generator Tube in Nuclear Power Plant (원전SG 세관 결함크기 예측을 위한 신경회로망 구조에 관한 연구)

  • Jo, Nam-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.63-70
    • /
    • 2010
  • In this paper, we study the structure of neural network for predicting defect size of steam generator tube. After extracting the features from the eddy current testing (ECT) signals, multi-layer neural networks are used to predict the defect size. In order to maximize the prediction performance for the defect size, we should carefully choose the structure of neural networks, especially the number of neurons in the hidden layer. In this paper, it is shown that, for the prediction of defect size, the number of neurons in the hidden layer can be efficiently determined by using cross-validation.