• 제목/요약/키워드: eco-energy

검색결과 1,088건 처리시간 0.034초

지속가능성 확보를 위한 생태마을 계획요소 개발 (The Development of Eco-village Planning Indicators for Sustainability)

  • 우혜미;반영운;한경민;백종인
    • 농촌계획
    • /
    • 제18권2호
    • /
    • pp.1-11
    • /
    • 2012
  • Eco-village has been regarded as an alternative to accomplish sustainable development for rural village. This study has intended to develop comprehensive planning indicators to establish an eco-village based on such aspects of sustainable development as economy, environment, and society. To reach this objective, this study has set up six goals as follows: 1) ecological production activities for agriculture, 2) resource circulation and energy independence in the economic domain; 3) building cultural and historical succession and community activation, and 4) living together with surrounding regions in social domain; and 5) maintaining environmental habitat, and 6) restoring natural ecosystem in environmental domain. Based on these goals, this study has developed the planning indicators to build an eco-village through case study, literature review, survey for suitability, and factor analysis. This study has found 17 strategies and 47 planning indicators in accordance with the six goals.

생태도시 구축을 위한 계획 특성에 관한 연구 - 독일 함부르크 하펜시티 사례를 중심으로 - (A Study on the Planning Characteristics of Ecological City - A Case Study of HafenCity, Hamburg -)

  • 박종기;진경일
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.3-12
    • /
    • 2012
  • Nowadays, interests on Eco-city planning as Solution for problems of energy demand and environmental change has grown. so Eco-city planning became a major political topic for urban planning and urban design in many advanced nation cities. The purpose of this study is to find out the organized characteristics of Eco-City planning by analyzing successful overseas case where wasted historic port area in city is are regenerated with a environment-friendly concept for Eco-City "HafenCity". It is located on Hamburg-mitte in Hamburg, Germany and is currently the largest construction project in Europe. HafenCity as Home to about 12,000 and the workplace of 40,000 people is being created to accommodate a variety of uses including residential buildings, business, office and retail space as well as cultural and leisure facilities. First of all, HafenCity impresses because of its size as well as because of its Urban planning for eco-city. It presents the excellent change from wasted historic port to the ecological urban space.

제품의 사용 후 처리전략 수립 최적화를 위한 계층적 에코 아키텍쳐 분석방법론 (The Eco-Architecture for Optimal End-Of-Life Strategy for Complex Products : An Extension to Hierarchical Analysis)

  • 곽민정;이현복;홍유석;조남욱;최건영
    • 대한산업공학회지
    • /
    • 제34권1호
    • /
    • pp.79-89
    • /
    • 2008
  • An end-of-life strategy is concerned with how to disassemble a product and what to do with each of the resultingdisassembled parts. A sound understanding of the end-of-life strategy at the early design stage could improve theease of disassembly and recycling in an efficient and effective manner. Therefore, the end-of-life decisionmaking for environmental conscious design has become a great concern to product manufacturers.We introduce a novel concept ofeco-architecture which represents a scheme by which the physical componentsare allocated to end-of-life modules. An end-of-life module is a physical chunk of connected components or afeasible subassembly which can be simultaneously processed by the same end-of-life option without furtherdisassembly. In this paper, a method for analyzing the eco-architecture of a product at the configuration designstage is proposed. It produces an optimal eco-architecture under the given environmental regulations. To dealwith the case ofa complex product, the method is extended for analyzing hierarchical eco-architecture.

우리나라 아파트 단지의 친환경계획 경향에 관한 연구 - 2000년대 수도권 지역 공공부문 아파트 단지를 중심으로 - (A Study on the Eco-friendly Planning Methods in Korean Apartment Houses - Focusing on the public sector housing in the Metropolitan Area in the 2000s -)

  • 김용국;서경욱
    • 한국실내디자인학회논문집
    • /
    • 제22권4호
    • /
    • pp.141-148
    • /
    • 2013
  • This study aims to investigate the eco-friendly planning methods for a sustainable apartment houses in the Metropolitan area of Seoul. Eco-friendly plans that considers the environmental issues were attempted from the beginning of 2000s, and since then, many apartment houses in Korea were built using this concept. They were, however, generally focusing on the physical and spatial aspects of the site plan. After the Seoul C40 weather summit conference in 2009, the low carbon green housing standard has been emphasized and thus the chemical concept was added to the existing physical planning methods. Under such a background, this study intends to investigate the eco-friendly plans for the apartment houses in the 2000s. This includes an ecological network plan, an ecological base plan, a building greening plan, a water treatment plan, and an energy saving plan. Based on the analysis and synthesis of these planning methods in the early 21st century, it would be possible to set up a proper future plan to enhance the sustainable built environment in the housing industry in the coming years.

BIM기반 건축물 설계 과정에서 실시간 에너지 성능 분석을 위한 기술 개발에 관한 연구 - 열관류율 분석을 중심으로 (A Study on the Development of the Technology of Evaluating the Performance of Energy - saving in the BIM-based Design Process in the Real Time Manner Focused on the Analysis of Coefficient of Overall Heat Transmission)

  • 이윤길;조원준
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.29-37
    • /
    • 2013
  • This study intended to introduce the method of designing an eco-friendly building based on BIM(Building Information Modeling) and BIM-based application. The proposed application aimed to generate the environmental performance of the designed alternative automatically in real-time manner in the process of architectural design. We focused on the feasibility of BIM-based eco-friendly design process and the applicability of the developed application for the architectural design practice. In this manner, in the end of paper, we proposed the so-call EcoBIM which is the performance evaluation module for the designed alternative using BIM in the real-time manner and the new design process with it. EcoBIM generate the coefficient of overall heat transmission of wall, roof and slab of the designed alternative with their physical characteristics such as thickness, thermal resistance and so on.

TIN-M(M=Co, NI) 복합 분리막의 제조 및 수소투과 특성평가 (Fabrications and Evaluations of Hydrogen Permeation on TIN-M(Co, NI) Composite Membrane)

  • 김경일;유성웅;홍태환
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.264-270
    • /
    • 2010
  • Recently, the most promising methods for high purity hydrogen production are membranes separation such as polymer, metal, ceramic and composites. It is well known that Pd and Pd-alloys membranes have excellent properties for hydrogen separation. However, it has hydrogen embrittlement and high cost for practical applications. Therefore, most scientists have studied new materials instead of Pd and Pd-alloys. On the other hand, TiN powders are great in resistance to acids and chemically stable under high operating temperature. In order to get specimens for hydrogen permeation, the TiN powders synthesized were consolidated together with Co, Ni powders by hot press sintering (HPS). During the consolidation of powders at HPS, heating rate was 10 K/min and the pressure was 10 MPa. It was characterized by XRD, SEM. Also, we estimated the hydrogen permeability by Sievert's type hydrogen permeation membrane equipment.

Fabrication and characterization of disposable golf tees using biodegradable polymer through 3D printing

  • Jihyuk Jung;Kwang Sun Huh;Jungho Jae;Kwang Se Lee
    • 청정기술
    • /
    • 제29권3호
    • /
    • pp.172-177
    • /
    • 2023
  • Many studies have been conducted on the indiscriminate use of plastic due to the environment problems it has caused all over the world. This problem can be mitigated by using eco-friendly/biodegradable plastics that can be decomposed by microorganisms or enzymes. This study focused on addressing the plastic golf tees that are thrown away at golf courses. In order to replace conventional golf tees (ABS) with a more eco-friendly alternative, this study explored a biodegradable plastic and 3D printing method for producing golf tees. Among the biodegradable plastics, PLA (polylactic acid) was found to be a good candidate as an eco-friendly material because it is biodegradable by microorganisms. Thus, golf tees were prepared by using PLA via 3D printing, and the physical and chemical properties of the tees were evaluated. The amorphous region of PLA was confirmed through XRD. Also, FT-IR showed the unique peak of PLA without impurities. It was confirmed through an optical microscope that the specific surface area and roughness had increased. This structure plays a role in firmly fixing the golf tee when it is inserted into the ground. In addition, it was possible to improve the compressive load compared to ABS golf tees while also decreasing the compressive stretching.

The effect of nano-sized starting materials and excess amount of Bi on the dielectric/piezoelectric properties of 0.94[(BixNa0.5)TiO3]-0.06[BaTiO3] lead free piezoelectric ceramics

  • Khansur, Neamul Hayet;Ur, Soon-Chul;Yoon, Man-Soon
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.31.1-31.1
    • /
    • 2009
  • In an approach to acclimate ourselves torecent ecological consciousness trend, a lead-free piezoelectric material, bismuth sodium titanate (abbreviated as BNT) based bismuth sodium barium titanate (abbreviated as BNT-BT), was considered as an environment-friendly alternative for a lead based piezoelectric system. Ceramic specimens of0.94[(BixNa0.5)TiO3]-0.06[BaTiO3] (x = 0.500~0.515) compositions were prepared by a modified mixed oxide method. To increase the chemical homogeneity andre action activity, high energy mechanical milling machine and pre-milled nanosized powder has been used. In this method (BixNa0.5)TiO3 (x=0.500~0.515) andBaTiO3 were prepared separately from pre-milled constituent materials at low calcination temperature and then separately prepared BNTX (X=1, 2, 3 and 4) and BT were mixed by high energy mechanical milling machine. Without further calcination step the mixed powders were pressed into disk shape and sintered at $1110^{\circ}C$. Microstructures, phase structures and electrical properties of the ceramic specimens were systematically investigated. Highly dense ceramic specimens with homogenous grains were prepared in spite of relatively low sintering temperature. Phase structures were not significantly influenced by the excess amount Bi. Large variation on the piezoelectric and dielectric properties was detected at relative high excess Bi amounts. When $x{\leq}0.505$, the specimens exhibit insignificant variation in piezoelectric and dielectric constant though depolarization temperature is found to be decreased. Considerable amount of decrease in piezoelectric and dielectric properties are observed with higher excess of Bi amounts ($x{\geq}0.505$). This research indicates the advantages of high energy mechanical milling and importance of proper maintenance of Bi stoichiometry.

  • PDF

공동주택의 환기시스템별 에너지성능 비교 분석 (A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House)

  • 김길태;전주영;김선동
    • 토지주택연구
    • /
    • 제6권4호
    • /
    • pp.215-220
    • /
    • 2015
  • 본 연구는 공동주택에 적용되고 있는 환기장치를 선정하고 환기장치의 에너지특성 분석과 에너지저감을 목적으로 시뮬레이션 프로그램 (ECO2)을 이용하여 환기장치 별 에너지성능평가를 수행하였으며, 아래와 같이 결과를 도출하였다. 공동주택을 대상으로 환기장치 별 에너지 효율등급평가 기준에 따른 소비량을 수행하고자 하였다. 또한 단지별 에너지소비량과 비교 검토 결과를 통하여 현재 우리나라에서 공동주택에 적용하고 있는 환기장치별 에너지 소비량 실태를 파악하였다. 중부지방의 84type, 한 개동을 대상으로 시뮬레이션한 결과, 자연환기장치의 등급용 1차에너지소요량 값은 $159.9kWh/m^2yr$, 전열교환환기장치 $161kWh/m^2yr$, 바닥환기장치 $179.7kWh/m^2yr$로 계산 되었다. 위 시뮬레이션 결과를 공동주택의 실제 현장자료로 검증하였으며, 환기장치별 에너지소요량에 대한 비율로 비교해본 결과, 전열교환환기방식이 자연환기방식에 비해 -1~6% 적은 값을 보였으며, 바닥배관환기방식이 자연환기방식에 비해 약 10~20% 더 많은 1차에너지소요량이 나타났다. 환기장치의 팬동력과 열회수효율에 따라 에너지소요량의 난방과 환기 값이 변화하며, 향후 기계환기장치의 효율화 및 최적화가 필요하다고 판단된다.

유출지하수열원 지열히트펌프의 냉난방성능 (Cooling and Heating Performance of Ground Source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.434-440
    • /
    • 2007
  • The Effluent ground water overflows in deep and broad ground space building. Temperature of effluent ground water is in 12$\sim$18$^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is 800$\sim$1000 ton/day. The heat pump capacity is 5RT each. The heat pump system heating COP was 3.0$\sim$3.3 for the open type and 3.3$\sim$3.8 for the close type system. The heat pump system cooling COP is 3.2$\sim$4.5 for the open type and 3.8$\sim$4.2 for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF