• Title/Summary/Keyword: echo time

Search Result 453, Processing Time 0.029 seconds

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Clinical Study of Acute and Chronic Pain by the Application of Magnetic Resonance Analyser $I_{TM}$ (자기공명분석기를 이용한 통증관리)

  • Park, Wook;Jin, Hee-Cheol;Cho, Myun-Hyun;Yoon, Suk-Jun;Lee, Jin-Seung;Lee, Jeong-Seok;Choi, Surk-Hwan;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.192-198
    • /
    • 1993
  • In 1984, a magnetic resonance spectrometer(magnetic resonance analyser, MRA $I_{TM}$) was developed by Sigrid Lipsett and Ronald J. Weinstock in the USA, Biomedical applications of the spectrometer have been examined by Dr. Hoang Van Duc(pathologist, USC), and Nakamura, et al(Japan). From their theoretical views, the biophysical functions of this machine are to analyse and synthesize a healthy tissue and organ resonance pattern, and to detect and correct an abnormal tissue and organ resonance pattern. All of the above functions are based on Quantum physics. The healthy tissue and organ resonance patterns are predetermined as standard magnetic resonance patterns by digitizing values based on peak resonance emissions(response levels or high pitched echo-sounds amplified via human body). In clinical practice, a counter or neutralizing resonance pattern calculated by the spectrometer can correct a phase-shifted resonance pattern(response levels or low pitched echo-sounds) of a diseased tissue and organ. By administering the counter resonance pattern into the site of pain and trigger point, it is possible to readjust the phase-shifted resonance pattern and then to alleviate pain through regulation of the neurotransmitter function of the nervous system. For assessing clinical effectiveness of pain relief with MRA $I_{TM}$ this study was designed to estimate pain intensity by the patient's subjective verbal rating scale(VRS such as graded to no pain, mild, moderate and severe) before application of it, to evaluate an amount of pain relief as applied the spectrometer by the patients subjective pain relief scale(visual analogue scale, VAS, 0~100%), and then to observe a continuation of pain relief following its application for managing acute and chronic pain in the 102 patients during an 8 months period beginning March, 1993. An application time of the spectrometer ranged from 15 to 30 minutes daily in each patient at or near the site of pain and trigger point when the patient wanted to be treated. The subjects consisted of 54 males and 48 females, with the age distribution between 23~40 years in 29 cases, 41~60 years in 48 cases and 61~76 years in 25 cases respectively(Table 1). The kinds of diagnosis and the main site of pain, the duration of pain before the application, and the frequency of it's application were recorded on the Table 2, 3 and 4. A distinction between acute and chronic pain was defined according to both of the pain intervals lasting within and over 3 months. The results of application of the spectrometer were noted as follows; In 51 cases of acute pain before the application, the pain intensities were rated mild in 10 cases, moderate in 15 cases and severe in 26 cases. The amounts of pain relief were noted as between 30~50% in 9 cases, 51~70% in 13 cases and 71~95% in 29 cases. The continuation of pain relief appeared between 6~24 hours in two cases, 2~5 days in 10 cases, 6~14 days in 4 cases, 15 days in one case, and completely relived of pain in 34 cases(Table 5~7). In 51 cases of chronic pain before the application, the pain intensities were rated mild in 12 cases, moderate in l8 cases and severe in 21 cases. The amounts of pain relief were noted as between 0~50% in 10 cases, 51~70% in 27 cases and 71~90% in 14 cases. The continuation of pain relief appeared to have no effect in two cases. The level of effective duration was between 6~12 hours in two cases, 2~5 days in 11 cases, 6~14 days in 14 cases, 15~60 days in 9 cases and in 13 cases the patient was completely relieved of pain(Table 5~7). There were no complications in the patients except a mild reddening and tingling sensation of skin while applying the spectrometer. Total amounts of pain relief in all of the subjects were accounted as poor and fair in 19(18.6%) cases, good in 40(39.2%) cases and excellent in 43(42.2%) cases. The clinical effectiveness of MRA $I_{TM}$ showed variable distributions from no improvements to complete relief of pain by the patient's assessment. In conclusion, we suggest that MRA $I_{TM}$ may be successful in immediate and continued pain relief but still requires several treatments for continued relief and may be gradually effective in pain relief while being applied repeatedly.

  • PDF

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF

Fabrication and Evaluation of High Frequency Ultrasound Receive Transducers for Intravascular Photoacoustic Imaging (혈관내 광음향 영상을 위한 고주파수 초음파 수신 변환기 제작 및 평가)

  • Lee, Jun-Su;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.300-308
    • /
    • 2014
  • Photoacoustic imaging is a useful tool for the diagnosis of atherosclerosis because it is capable of providing anatomical and pathological information at the same time. A photoacoustic signal detector is a pivotal element to achieve high spatial resolution, so that it should have broadband spectrum with a high center frequency. Since a photoacoustic imaging probe is directly inserted into blood vessel to diagnose atherosclerosis, the total size of the photoacoustic signal detector should be less than 1 mm. The main purpose of this paper is to demonstrate that PVDF can be used as an active material for the photoacoustic signal detector with a high frequency and broadband characteristic. The photoacoustic signal detector developed in this study was a single element ultrasound transducer with an aperture of $0.5{\times}0.5mm$ and the total size of 1 mm. In the design stage, the natural focal depth was adjusted for an effective focal area to cover the region of interest, i.e., 1~5 mm in depth. This was because geometrical focusing could not be used due to the small aperture. Through a pulse-echo test, it was ascertained that the developed photoacoustic signal detector has the -6 dB bandwidth ranging between 40.1 and 112.8 MHz and the center frequency of 76.83 MHz.

Characteristics of the E- and F-region field-aligned irregularities in middle latitudes: Initial results obtained from the Daejeon 40.8 MHz VHF radar in South Korea

  • Kwak, Young-Sil;Yang, Tae-Yong;Kil, Hoysub;Phanikumar, Devulapalli Venkata;Heo, Bok-Haeng;Lee, Jae-Jin;Hwang, Junga;Choi, Seong-Hwan;Park, Young-Deuk;Choi, Ho-Seong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.15-23
    • /
    • 2014
  • We present preliminary observations of the field-aligned-irregularities (FAIs) in the E and F regions during the solar minimum (2009 - 2010) using the 40.8 MHz coherent backscatter radar at Daejeon ($36.18^{\circ}N$, $127.14^{\circ}E$, $26.7^{\circ}N$ dip latitude) in South Korea. The radar, which consists of 24 Yagi antennas, observes the FAIs using a single beam with a peak power of 24 kW. The radar has been continuously operated since December 2009. Depending on the manner of occurrence of the backscatter echoes, the E-region echoes are largely divided into two types: quasi-periodic (QP) and continuous echoes. Our observations show that the QP echoes occur frequently above an altitude of 105 km in the post-sunset period and continuous echoes occur preferentially around an altitude of 105 km in the post-sunrise period. QP echoes appear as striated discrete echoes for a period of about 10 - 20 min. The QP-type echoes occur more frequently than the continuous-type echoes do and the echo intensity of the QP type is stronger than that of the continuous type. In the F region, the FAIs occur at night at an altitude interval of 250 - 450 km. As time proceeds, the occurrence height of the FAIs gradually increases until early in the morning and then decreases. The duration of the F-region FAIs is typically a few hours at night, although, in rare cases, FAIs persist throughout the night or appear even after sunrise. We discuss the similarities and differences of the FAIs observed by the Daejeon radar in comparison with other radar observations.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

The Clinical Study of Biyun(sinusitis) in Children (소아비연(小兒鼻淵)에 대(對)한 임상적(臨床的) 연구(硏究))

  • Park Eun-Jeong;Lee Hae-Ja
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.111-131
    • /
    • 1998
  • 1. In oriental medicine, the case of sinusitis can be explained, not only external invasion such as PUNG HAN(wind-cold), PUNG YUL(wind-hot), SHUP YUL(damp-heat), but also functional disorder of internal organ such as spleen(脾), lung(肺), kidney(腎) The western medicine classified the cause of sinusitis as two factors. That is bacterial infection factor-Haemophilus influenza, streptococcus pyogeues, streptococcus pneumonia- and viral infection factor-Rhinovirus, parainfluenza, Echo28, Coxsacki21, Sinusitis is complicated to allergic rhinitis, chronic otitis media purulent, chronic tonsilitis, sinubronchitis. On the condition of nasal septum deformity, turbinates deformity, nasal septum deviation, sinusitis can be developed. the predisposing factors of sinusitis is swimming, air pollution, malnutrition, shortage of immunity.2. According to survey, sinusitis occurred that children from 4 to 12 years old and from 5 to 7 years old occupied 70% 3. From the past history data, they experienced chronic tonsillar hypertropy(20%), otitis media, atopic dermatitis, allergic rhinitis, bronchial asthma, pneumonia, bronchiolitis, chronic sore throat, urticaria, milk allergy in sequence. 4. the symptoms of sinusitis is nasal obstruction, postnasal dripping, purulunt(yellow)or white discharge, cough, nose bleeding in sequence. nasal obstruction take the portion of 95%, postnasal dripping 65%, night time or early morning cough 60%. 5. The suffering period of sinusitis is 6 month minimum, 4 years maximum, most cases are included in a year. The suffering period of children was shorter than adult. 6. Diagnosis depend on inspection of nasal cavity, postnasal dripping, X-ray finding. 75% of patient(15case) showed both maxillary sinusitis, 25%(5cases) showed left or right maxillary sinusitis. 7. Treatment of oriental medicine, consist of Herb-medicine, acupuncture and exposing of Lazer beam. Kamihyunggyeyungyotang(加味荊芥蓮翹湯) is administered mainly as the medical therapy, Kamigwaghyangjeungkisan(加味藿香正氣散) Kimizwakwieum(加味左歸飮), Kamihyangsosan(加味香蘇散) is administered for a additional symptoms which occurred by influenza recurrence. Kamijeonxibackchulsan(加味錢氏白朮散) is administered to treat gastro-intestine trouble patients who have sinusitis. 8. The period of treatment is varied with patient conditions and X-ray finding. The minimal period is 35days, maximal period is 202days. So it took about 86days in average and about 50% of patient(10cases) is recovered in one or two month.

  • PDF

Sounding Observation with Wind Profiler and Radiometer of the Yeongdong Thundersnow on 20 January 2017 (2017년 1월 20일 영동 뇌설 사례에 대한 연직바람관측장비와 라디오미터 관측 자료의 분석)

  • Kwon, Ju-Hyeong;Kwon, Tae-Yong;Kim, Byung-Gon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.465-480
    • /
    • 2018
  • On 20 January 2017, the fresh snow cover which is more than 20 cm, accompaning with lightning occurred over Yeongdong coastal region for the first 3-hour of the heavy snowfall event. This study analyzed sounding observations in the heavy snow period which were including the measurements of wind profiler, radiometer and rawinsonde. The features examined from the vertical wind and temperature data at the two adjacent stations, Bukgangneung and Gangneung-Wonju National University, are summarized as follows: 1) The strong (30-40 kts) north-east winds were observed in the level from 2 to 6 km. The Strong atmospheric instability was found from 4 to 6 km, in which the lapse rate of temperature was about $-18^{\circ}C\;km^{-1}$. These features indicate that the deep convective cloud develops up to the height of 6 km in the heavy snowfall period, which is shown in the satellite infrared images. 2) The cooling was observed in the level below 1 km. At this time, the surface air temperature at Bukgangneung station decreased by $4^{\circ}C$. The narrow cooling zone estimated from AWS and buoy data was located in east-west direction. These are the features observed in the cold front of extratropical cyclone. The distributions of radar echo and lightning also show the same shape in east-west direction. Therefore, the results indicate that the Yeongdong thundersnow event was the combined precipitation system of deep convective cloud and cold frontal precipitation.

A Study on Noise Characteristic of Multi-channel Seismic Data for the Hydrothermal Deposit Survey at Lau Basin, South Pacific (열수광상 탐사를 위한 남태평양 라우분지 다중채널 탄성파 자료의 잡음특성 연구)

  • Ok, Soo-Jong;Ha, Young-Soo;Lee, Jin-Woo;Shin, Sung-Ryul
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.235-235
    • /
    • 2011
  • Lau basin of south Pacific, as an active back arc basin, is promising area bearing seafloor massive hydrothermal deposit that is located in a subduction zone between the Pacific ocean plate and Indo-Australian continental plate. Korea Ocean Research and Development Institute tracked from 2004 to 2006 the hydrothermal activity to the extension of the northeast Lau Basin, targeting seamount. hydrothermal activity by tracking was found hydrothermal evidences. In this study, Marine seismic survey was carried out in the Lau basin seamount of the possibility of hydrothermal deposit. In particular, Marine magnetic survey and seismic survey was carried out at the same time in TA-12 seamount and noise characteristics were found in the seamount. the main process of data processing is Bandpass filter, FK filter, Deconvolution for noise attenuation such backscatter and multiple reflections. the migration is performed to compensate for reflection points followed by seamount of a slope. In this study, bedrock and upper strata could be identified and in the Future, the comparative method with Multi Beam Echo Sounder(MBES) are likely to derive the correct velocity model, the marine magnetic survey results should be considered.

  • PDF