• 제목/요약/키워드: eccentric

검색결과 899건 처리시간 0.023초

불평형 전자기력을 고려한 유도전동기 회전자의 불평형 응답해석 (Unbalance Response Analysis of Induction Motor Rotor Considering Unbalanced Electromagnetic Forces)

  • 손병구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.201-209
    • /
    • 1999
  • This paper presents a general analytical method for analyzing mechanical unbalance response of unbalanced electromagnetic forces produced in induction motors with an eccentric rotor and a phase unbalance. The equations to be solved are a set of second order differential equations which give matrices with periodic coefficients that are a function of time due to the unbalanced electro-magnetic force. Unbalance response is processed by Newmark $\beta$ method. Two examples are given including an industrial application. The results show that the method proposed is satisfactory.

  • PDF

로터리 압축기 회전체-베어링계의 동적 거동해석 (Dynamic Behavior Analysis of Rotor-Bearing System for Rotary Compressor)

  • 김태학
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.244-251
    • /
    • 1999
  • Large dynamic loads act on the rotor in rotary compressors. There are unbalance forces due to eccentric rotation parts and gas forces induced by the pressure difference between compression and suction gases. Rotor-journal bearing system is nonlinear since the stiffness and damping coef-ficients of the lubrication oil film are not constant in the bearings. in this paper the program for predicting the behaviors of rotor-journal bearing system of rotary compressor is developed. Finite element modeling is used to analyze the flexible rotor. The numerical results are compared with experimental results.

  • PDF

편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구 (An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings)

  • 최산호;서성연
    • 한국강구조학회 논문집
    • /
    • 제12권5호통권48호
    • /
    • pp.595-604
    • /
    • 2000
  • 유공합성보는 공기조화설비등의 각종 배관으로 인한 용적률의 저하를 완화할 수 있고, 바람과 같은 수평력에 의한 층모멘트 감소등의 구조적 측면에서도 유용하다. 또한 휨강성도 증가되어 하중에 의한 처짐이 적어지고 진동하중이나 충격하중에도 유리하게 되어 건축물의 강성 및 내력을 높이기 위해 사용되고 있다. 그러나 개구부 위치 및 편심여부에 따라 외력에 대한 구조적인 거동이 달라지게 되므로 이에 대한 적절한 검토가 요구된다. 이에 본 논문은 편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구로서, 무공합성보인 기준시험체와 중심 및 상 하 편심유공합성보 시험체의 실험 및 이론적 고찰을 통하여 각 시험체들의 항복 및 최대내력, 휨 및 전단강성, 개구부주위의 응력분포, 그리고 모멘트-전단력 상관관계등의 구조적 특성을 규명코자 한다.

  • PDF

800MPa 강재 및 100MPa 콘크리트를 적용한 매입형 합성기둥의 구조성능 (Structural Performance of Concrete-encased Steel Columns using 800MPa Steel and 100MPa Concrete)

  • 김창수;박홍근;최인락;정경수;김진호
    • 한국강구조학회 논문집
    • /
    • 제22권5호
    • /
    • pp.497-509
    • /
    • 2010
  • 고강도강재 및 고강도콘크리트를 적용한 매입형 합성기둥의 편심압축시 거동특성을 연구하기 위하여, 항복강도 $f_{ys}$=913MPa 강재와 압축강도 $f_{ck}$97.7MPa 콘크리트를 사용하여 실험연구를 실시하였다. 주요변수는 횡철근의 종류, 항복강도, 배근간격, 그리고 편심하중거리이다. 거동특성을 분석하기 위하여 구속효과와 변형률적합조건을 적용한 비선형 단면해석을 실시하였으며, 현행 설계기준들의 적용성을 판단하기 위해 실험결과와 비교하였다. 횡구속효과에 의하여 콘크리트의 연성능력은 증가하였으며, 이에 따라 단면의 휨모멘트강도가 증가하였다. 비선형해석을 통해 합성단면의 축력-모멘트 상관관계를 예측한 결과는 실험결과와 잘 일치한 반면, 강재의 완전소성강도를 사용하는 Eurocode 4는 실험체의 성능을 과대평가하였으며, 콘크리트의 횡구속효과를 고려하지 않은 ACI 318은 과소평가하였다.

유한요소해석을 통한 의료용 리프트 칼럼의 피로수명 예측 (Fatigue Life Prediction of Medical Lift Column utilizing Finite Element Analysis)

  • 천희준;조진래;양희준;이시복
    • 한국전산구조공학회논문집
    • /
    • 제24권3호
    • /
    • pp.337-342
    • /
    • 2011
  • 매우 큰 편심하중을 지지하면서 상하로 수직위치를 제어하는 의료용 리프트 칼럼은 수직위치의 정확도를 확보하기 위해 매우 낮은 구조적 변형과 진동은 물론 높은 피로강도가 요구된다. 리프트 칼럼은 일반적으로 3단 슬라이딩 붐구조로 유도전동기로 작동되며, 상하운동에 따라 변동응력을 나타낸다. 본 연구에서는 리프트 칼럼의 상하운동으로 야기되는 변동응력에 따른 피로강도를 수치해석적으로 예측하였다. 한 주기 상하운동에 따른 응력변동은 유한요소해석으로 구하였으며, 피로수명은 Palmgren-miner기법과 재료의 S-N선도를 적용하여 예측하였다. 수치해석의 신뢰성을 확보하기 위하여 리프트 칼럼의 상세형상과 체결부위을 반영한 3차원 FEM모델을 생성하였으며, 칼럼과 패드사이 계면은 접촉조건으로 처리하였다.

PRI를 이용한 측두하악장애에 관한 연구 (A Study of TMJ dysfunction using PRI)

  • Kwang Ho Lee;Sung Woo Lee
    • Journal of Oral Medicine and Pain
    • /
    • 제11권1호
    • /
    • pp.57-66
    • /
    • 1986
  • A study of occlusal relationship and TMJ dysfunction, parafunctional relationship and TMJ dysfunction using PRI was investigated in 23 dental students without history of being treated, ranging from 19 to 24 years old. The author used Denar Pantronic and D5-A articulator to study above. The obtained results were as follows : 1. Distribution of PRI in experimental subjects was as follows. None 13%, Slight 43%, Moderate 40%, Severe 4% Prevalance of TMJ Dysfunction was 87% 2. PRI scores of occlusal group Aoi (less than 5 in Helkimo occlusion/articulation index) was $11.72\pm2.32$ , those of occlusal group Boi (more than 5 in Helkimo occlusion/articulation index) 23.0 $\pm$ 8.06. There was a significant difference between group Aoi and group Boi(P<0.01) 3. PRI scores of occlusal group Ald (no eccentric interference, less than 0.5mm in lateral shift of slide in centric) was 12.0 $\pm$ 2.49, those of occlusal group Bld(no eccentric interference, less than 0.5mm in lateral shift of slide in centric) 24.5$\pm$5.33 There was a significant difference between group Ald and group Bld(P<0.05) 4. Prevalance of parafunction subjects(%) was 65.2%. 5. PRI scores of parafunction group was 21.6 $\pm$ 9.48, those of nonparafunctional group 18.7 $\pm$ 9.06. There was not significant difference between parafunctional group and nonparafunctional group(P>0.1)

  • PDF

T-Scan system을 이용한 측두하악 장애 환자의 교합 분석에 관한 연구 (OCCLUSAL ANALYSIS OF PATIENTS WITH TEMPOROMANDIBULAR DYSFUNCTION BY USE OF T-SCAN SYSTEM)

  • 박선주;정재헌
    • 대한치과보철학회지
    • /
    • 제29권3호
    • /
    • pp.121-140
    • /
    • 1991
  • Fifteen dental college students of Chosun University without the abnormal occlusion, the history and symptom of temporomandibular dysfunction(TMD), and who had all permanent teeth except third molar and the fifteen moderate group and the fifteen severe group classified according to Helkimo's dysfunction index among patients on the basis of the symptom of TMD were selected. The occlusal contact, occlusal force and occlusal interference in eccentric movement was studied and analyzed using T-Scan system. The result were as follows : 1. The TLR centering around midsagittal axis was located at $1.42{\pm}0.82mm$ in control group, $3.36{\pm}1.45mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsagittal axis. 2. The PLR from the first contact to the fifth contact centering around midsagittal axis was located at $1.73{\pm}1.78mm$ in control group, $3.36{\pm}1.41mm$ in moderate group, and $5.39{\pm}4.32mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsgittal axis. 3. The TFB, PFB, RFB and LFB of occlusal contact centering around incisal axis had no significant difference statistically among control group, moderate group, and severe group, and it was located at first molar. 4.The LF and RF was smaller in TMD group than in control group. 5. The LR moment of occlusal force centering around midsagittal axis was located at $178.51{\pm}139.81N.mm$ in control group, $466.25{\pm}296.47N.mm$ in moderate group, and $749.18{\pm}588.18N.mm$ in severe group. And as TMD was heavier, it was located at the farther point from midsagittal axis. 6. The RL and LL of occlusal force centering around incisal axis had not-significance statistically among control group, moderate group, and severe group, and it was at the first molar. 7. The number of occlusal interference of the eccentric movement was increased in the patients of TMD.

  • PDF

소립종자용 평면배열 진공노즐식 반자동 파종기 개발에 관한 연구 (Development of a Semi-automatic Seeder with Vacuum Nozzles of Quadratic Arrangement for Small-sized Seeds)

  • 김동억;이공인;강동현;김유호;이혜진;김현환;김종구;김용현
    • Journal of Biosystems Engineering
    • /
    • 제36권6호
    • /
    • pp.434-443
    • /
    • 2011
  • A large scale seeding system was stable in terms of techniques but a convenient seeding system of small size was unsettled. This study was performed to develop a semi-automatic seeder for small and medium sized scale farm. To investigate optimum needle diameter and vacuum pressure was used vacuum suction needle seeder. Although the needle diameter according to the kinds of seed was different, the needle diameter for salvia and lettuce seed was suitable for 0.34 mm needle nozzle and 0.4 mm taper nozzle. The prototype consisted a seeding frame attached with needle nozzle, seed hopper, vibrating device, seeding part, vacuum ejector, seed tube etc.. As the result with the experiments, the seeding rate of the seeder was 92% and more at 0.34 mm diameter needle nozzle and 0.4 mm taper nozzle. Eccentric weight for seed hopper vibration was suitable that weight is 11 g and eccentric distance is 0.5 mm. Vibration acceleration of upward direction was 0.363 m/$s^2$. Working capacity of the seeder was possible 160 trays per hour. It was possible for sowing small seeds but it was required to make compact and simple model.

부척추근의 근피로가 하지의 고유수용성 감각과 협응 능력에 미치는 영향 (Effect of Paraspinal Muscle Fatigue on Proprioception and Coordination of the Lower Limb)

  • 박민철;김형수;이상열;이명희;구봉오;윤창구
    • 대한물리의학회지
    • /
    • 제3권4호
    • /
    • pp.255-260
    • /
    • 2008
  • Purpose : This study was performed to find out the influence of the change on proprioception and coordination of the lower limb by experimentally induced paraspinal muscle fatigue, Methods : Twelve subjects(6 males, 6 females) with no history low back and lower limbs problem volunteered for this study. Subjects were pre-tested proprioception and coordination using the MR-FSS(Mornitored Rehab Functional Squat System). And then the subjects performed isometric paraspinal muscles contraction for induced muscle fatigue. Muscle fatigue was defined surface EMG(MP 150). After isometric contraction, the subjects were post-tested using the MR-FSS. Results : In comparison of coordination, deviation of concentric coordination was increased(from $0.50{\pm}0.13cm$ to $0.67{\pm}0.21$)(p<0.05) and deviation of eccentric coordination was also increased(from $0.51{\pm}0.15cm$ to $0.70{\pm}0.26cm$)(p<0.05). And deviation movement of proprioceptive test was increased(from $4.98{\pm}1.80cm$ to $5.69{\pm}1.98cm$), but there was no significant different(p>0.05). Conclusion : Fatigue of paraspinal muscles was decreased concentric and eccentric coordination of the lower limb.

  • PDF

이종강종을 사용한 고강도 CFT 합성부재의 구조성능 (Structural Performance of High-Strength Concrete-Filled Steel Tube Steel Columns using Different Strength Steels)

  • 최인락;정경수;김진호;홍건호
    • 한국강구조학회 논문집
    • /
    • 제24권6호
    • /
    • pp.711-723
    • /
    • 2012
  • 플랜지와 웨브에 서로 강도가 다른 이종강재를 사용한 CFT 합성구조의 거동특성을 파악하기 위하여, 플랜지는 건축용 800MPa급 강재인 HSA800, 웨브에는 일반강도 강재인 SM490 강재를 사용하여 실험연구를 수행하였다. 주요실험 변수는 강관의 강도 조합, 충전된 콘크리트의 강도, 콘크리트 충전효과이다. 이종강재간의 용접접합부는 낮은강도 강재에 적합한 용접부를 사용하여 접합부 성능을 검증하였다. 실험체의 거동특성을 평가하기 위해 편심압축 실험을 수행하였으며, 현행 설계기준들에 따른 예측결과와 비교하였다. 플랜지에 고강도 강재를 적용함에 따라 단면의 축강도 및 휨모멘트강도가 증가하였으며, 부재 강도를 충분히 발현한 이후 용접부에서 파괴가 일어났다. 실험결과 현행 설계기준을 적용하여 합성단면의 축력-모멘트 상관관계 및 유효휨강성을 안전측으로 예측 가능하였다.